Optimization of solid-phase extraction for a liquid chromatographic-tandem mass spectrometric general unknown screening procedure by means of computational techniques

被引:34
作者
Decaestecker, TN
Lambert, WE
Van Peteghem, CH
Deforce, D
Van Bocxlaer, JF
机构
[1] Univ Ghent, Lab Med Biochem & Clin Anal, B-9000 Ghent, Belgium
[2] Univ Ghent, Toxicol Lab, B-9000 Ghent, Belgium
[3] Univ Ghent, Lab Pharmaceut Biotechnol, B-9000 Ghent, Belgium
关键词
general unknown screening; screening; experimental design; solid-phase extraction; information-dependent acquisition;
D O I
10.1016/j.chroma.2004.06.010
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A solid-phase extraction (SPE) method was optimized to suit the particular demands of an information-dependent acquisition LC-MS-MS procedure for general unknown screening in a forensic toxicology setting. In a first phase, a Plackett-Burman screening design with fold-over was carried out to distinguish the significant factors affecting the extraction procedure. This part eventuated in the determination of only three statistically relevant parameters, requiring consecutive optimization. To that end, in phase II of this study, a rotatable central composite design was applied to define the response surface as a function of the significant parameters and to choose the optimal conditions for the SPE. (C) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:57 / 65
页数:9
相关论文
共 17 条
[1]  
BARRENTINE LB, 1997, QUAL ENG, V9, P11
[2]   SIMULTANEOUS-OPTIMIZATION OF SEVERAL CHROMATOGRAPHIC PERFORMANCE GOALS USING DERRINGER DESIRABILITY FUNCTION [J].
BOURGUIGNON, B ;
MASSART, DL .
JOURNAL OF CHROMATOGRAPHY, 1991, 586 (01) :11-20
[3]  
Decaestecker TN, 2000, RAPID COMMUN MASS SP, V14, P1787, DOI 10.1002/1097-0231(20001015)14:19<1787::AID-RCM94>3.0.CO
[4]  
2-S
[5]   Suitability testing of commercial solid-phase extraction sorbents for sample clean-up in systematic toxicological analysis using liquid chromatography-(tandem) mass spectrometry [J].
Decaestecker, TN ;
Coopman, EM ;
Van Peteghem, CH ;
Van Bocxlaer, JF .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2003, 789 (01) :19-25
[6]  
Deng LY, 1999, STAT SINICA, V9, P1071
[7]   QUICK AND EASY ANALYSIS OF UNREPLICATED FACTORIALS [J].
LENTH, RV .
TECHNOMETRICS, 1989, 31 (04) :469-473
[8]   Optimal foldover plans for two-level nonregular orthogonal designs [J].
Li, W ;
Lin, DKJ ;
Ye, KQ .
TECHNOMETRICS, 2003, 45 (04) :347-351
[9]  
Massart D. L., 1997, HDB CHEMOMETRICS Q A, p[643, 701]
[10]  
Myers R. H., 2016, Response Surface Methodology: Process and Product Optimization Using Designed Experiments, Ved.).