ULTRASTRUCTURE AND RETINAL IMAGING OF INTERNAL LIMITING MEMBRANE A Clinicopathologic Correlation of Trypan Blue Stain in Macular Hole Surgery

被引:10
|
作者
Mackenzie, Sarah E. [1 ]
Gandorfer, Arnd [2 ]
Rohleder, Matthias [2 ]
Schumann, Ricarda [2 ]
Schlottmann, Patricio G. [1 ]
Bunce, Catey [1 ]
Xing, Wen [1 ]
Gregor, Zdenek [1 ]
Charteris, David G. [1 ]
机构
[1] Moorfields Eye Hosp, London EC1V 2PD, England
[2] Univ Eye Hosp Munich, Vitreoretinal & Pathol Unit, Munich, Germany
来源
RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES | 2010年 / 30卷 / 04期
关键词
electron microscopy; epimacular tissue; internal limiting membrane; macular hole; optical coherence tomography; trypan blue; INDOCYANINE-GREEN; PUCKER SURGERY; VITRECTOMY; EPITHELIUM;
D O I
10.1097/IAE.0b013e3181bced50
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: The purpose of this study was to correlate the ultrastructural morphology of epiretinal and retinal tissue with optical coherence tomography assessment and to investigate the effects of trypan blue staining on internal limiting membrane (ILM) tissue. Methods: This was a prospective case-comparative study. Consecutive patients were recruited and underwent ILM peel with 0.5 mL of 0.15% trypan blue, and these were compared with a nonrandomized control group (unstained ILM). Patients underwent optical coherence tomography scanning preoperatively and postoperatively at 1.5 and 3 months. Data were collected prospectively to include Snellen visual acuity, macular hole, and operative characteristics. Internal limiting membrane was examined by transmission electron microscopy. Results: Sixty-four patients underwent macular hole surgery, and complete data were available on 49 patients (17 control subjects and 32 patients who had peeling of stained ILM). Trypan blue staining significantly improved ease and completeness of ILM removal. There was no significant difference in vision, optical coherence tomography characteristics, or macular hole closure rate at 3 months between stained and unstained groups. There was no ultrastructural evidence of alteration of the plane of ILM separation in cases in which trypan blue was used. Conclusion: Trypan blue stain from these data seems to improve the ease and completeness of the ILM peeling (assessed clinically) and does not show any signs of toxicity. RETINA 30: 655-661, 2010
引用
收藏
页码:655 / 661
页数:7
相关论文
共 50 条
  • [41] Retinal thickness in eyes with idiopathic macular hole after vitrectomy with internal limiting membrane peeling
    Ohta, Kouichi
    Sato, Atsuko
    Fukui, Emi
    GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2013, 251 (05) : 1273 - 1279
  • [42] MANAGEMENT OF RHEGMATOGENOUS RETINAL DETACHMENT WITH COEXISTING MACULAR HOLE A Comparison of Vitrectomy With and Without Internal Limiting Membrane Peeling
    Shukla, Dhananjay
    Kalliath, Jay
    Srinivasan, Karthik
    Neelakantan, Nithya
    Rajendran, Anand
    Naresh, Kannan B.
    Behera, Umesh C.
    RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES, 2013, 33 (03): : 571 - 578
  • [43] BRILLIANT BLUE G-ASSISTED INTERNAL LIMITING MEMBRANE PEELING FOR MACULAR HOLE A Systematic Review of Literature and Meta-Analysis
    Azuma, Kunihiro
    Noda, Yasuo
    Hirasawa, Kazunori
    Ueta, Takashi
    RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES, 2016, 36 (05): : 851 - 858
  • [44] Internal limiting membrane flap technique in macular hole surgery
    Qian Xu
    Jie Luan
    International Journal of Ophthalmology, 2020, 13 (05) : 822 - 831
  • [45] Perifoveal Microvascular Changes Following Internal Limiting Membrane Peeling Surgery for Epiretinal Membrane and Macular Hole
    Kim, Kiyoung
    Yoon, Kyungwoo
    Park, Jong Beom
    Kang, Min Seok
    Kim, Eung Suk
    Yu, Seung-Young
    OPHTHALMOLOGICA, 2023, 246 (5-6) : 324 - 332
  • [46] Inverted internal limiting membrane flap technique versus complete internal limiting membrane peeling in large macular hole surgery: a comparative study
    Ramtohul, Prithvi
    Parrat, Eric
    Denis, Daniele
    Lorenzi, Umberto
    BMC OPHTHALMOLOGY, 2020, 20 (01)
  • [47] Internal limiting membrane peeling in vitreo-retinal surgery
    Abdelkader, Ehab
    Lois, Noemi
    SURVEY OF OPHTHALMOLOGY, 2008, 53 (04) : 368 - 396
  • [48] Inverted internal limiting membrane flap technique versus complete internal limiting membrane peeling in large macular hole surgery: a comparative study
    Prithvi Ramtohul
    Eric Parrat
    Danièle Denis
    Umberto Lorenzi
    BMC Ophthalmology, 20
  • [49] Macular Hole Closure With Internal Limiting Membrane Abrasion Technique
    Mahajan, Vinit B.
    Chin, Eric K.
    Tarantola, Ryan M.
    Almeida, David R. P.
    Somani, Riz
    Boldt, H. Culver
    Folk, James C.
    Gehrs, Karen M.
    Russell, Stephen R.
    JAMA OPHTHALMOLOGY, 2015, 133 (06) : 635 - 641
  • [50] MACULAR HOLE SURGERY AND RETINAL TECTONICSThe Impact of Internal Limiting Membrane Peeling Size on Tangential Retinal Displacement
    Pellegrini, Marco
    Adamo, Ginevra
    Vivarelli, Chiara
    Bizzarri, Alice
    Mondin, Riccardo
    Talli, Pietro Maria
    Nasini, Francesco
    Giannaccare, Giuseppe
    Mura, Marco
    RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES, 2025, 45 (01): : 23 - 29