Application of transcranial magnetic stimulation for major depression: Coil design and neuroanatomical variability considerations
被引:40
作者:
Zibman, Samuel
[1
,2
]
Pell, Gaby S.
[1
,2
]
Barnea-Ygael, Noam
[1
,2
]
Roth, Yiftach
[1
,2
]
Zangen, Abraham
[1
,2
]
机构:
[1] Ben Gurion Univ Negev, Dept Life Sci, Beer Sheva, Israel
[2] Ben Gurion Univ Negev, Zlotowski Ctr Neurosci, Beer Sheva, Israel
关键词:
TMS;
MDD;
Deep TMS;
Figure of 8 coil;
H-coil;
Depression;
TREATMENT-RESISTANT DEPRESSION;
DEPTH-FOCALITY TRADEOFF;
ELECTRIC-FIELD;
FUNCTIONAL CONNECTIVITY;
CEREBRAL-CORTEX;
MOTOR CORTEX;
DOUBLE-BLIND;
DEEP TMS;
ADD-ON;
DISORDER;
D O I:
10.1016/j.euroneuro.2019.06.009
中图分类号:
R74 [神经病学与精神病学];
学科分类号:
摘要:
High-frequency repeated transcranial magnetic stimulation (rTMS) as a treatment for major de-pressive disorder (MDD) has received FDA clearance for both the figure-of-8 coil (figure-8 coil) and the H1 coil. The FDA-cleared MDD protocols for both coils include high frequency (10-18 Hz) stimulation targeting the dorsolateral prefrontal cortex (dlPFC) at an intensity that is 120% of the right-hand resting motor threshold. Despite these similar parameters, the two coils gen-erate distinct electrical fields (e-fields) which result in differences in the cortical stimulation they produce. Due to the differences in coil designs, the H1 coil induces a stimulation e-field that is broader and deeper than the one induced by the figure-8 coil. In this paper we review theoretical and clinical implications of these differences between the two coils and compare evidence of their safety and efficacy in treating MDD. We present the design principles of the coils, the challenges of identifying, finding, and stimulating the op-timal brain target of each individual (both from functional and connectivity perspectives), and the possible implication of stimulating outside that target. There is only one study that performed a direct comparison between clinical effectiveness of the two coils, using the stan-dard FDA-approved protocols in MDD patients. This study indicated clinical superiority of the H1 coil but did not measure long-term effects. Post-marketing data suggest that both coils have a similar safety profile in clinical practice, whereas effect size comparisons of the two respective FDA pivotal trials suggests that the H1 coil may have an advantage in efficacy. We conclude that further head-to-head experiments are needed, especially ones that will compare long-term effects , usage of similar temporal stimulation parameters and similar number of pulses. (c) 2019 The Authors. Published by Elsevier B.V. This is an open access article under the CC BY-NC-ND license. ( http://creativecommons.org/licenses/by-nc-nd/4.0/ )
引用
收藏
页码:73 / 88
页数:16
相关论文