MAGIC ANGLE EFFECT IN NORMAL COLLATERAL LIGAMENTS OF THE DISTAL INTERPHALANGEAL JOINT IN HORSES IMAGED WITH A HIGH-FIELD MAGNETIC RESONANCE IMAGING SYSTEM

被引:20
作者
Werpy, Natasha M. [1 ]
Ho, Charles P. [2 ,3 ]
Kawcak, Christopher E. [1 ]
机构
[1] Colorado State Univ, Equine Orthopaed Res Ctr, Vet Teaching Hosp, Ft Collins, CO 80523 USA
[2] Steadman Hawkins Res Fdn, Vail, CO 81657 USA
[3] Radnet, Los Angeles, CA 90025 USA
关键词
collateral ligaments of the DIP joint; magic angle effect; equine; DIGITAL FLEXOR TENDON; SIGNAL INTENSITY; ORIENTATION; MANIFESTATION;
D O I
10.1111/j.1740-8261.2009.01613.x
中图分类号
S85 [动物医学(兽医学)];
学科分类号
0906 ;
摘要
Distal forelimb specimens of eight skeletally mature horses were imaged using proton density turbo spin echo, T1-weighted spoiled gradient echo, T2*-weighted gradient echo, short tau inversion recovery and T2-weighted fast spin echo sequences with the limb parallel to the main magnetic field, and with angulation of the limb relative to the main magnetic field. The magic angle effect can be identified in the collateral ligaments of the distal interphalangeal joint when imaged in a high-field magnetic resonance (MR) imaging system with a horizontally oriented main magnetic field. This effect has previously been described in the collateral ligaments of the distal interphalangeal joint in a low-field system with a vertically oriented main magnetic field. The curvature of the ligaments places the fibers at the magic angle in both horizontally and vertically orientated main magnetic fields. This effect can be identified on short time of echo sequences and impacts the signal pattern of the ligaments at the level of the middle phalanx with the limb in a neutral position and with angulation of the limb. Magic angle effect should be considered as a possible cause of an asymmetrical signal pattern, depending on the positioning of the limb and the sequences used for imaging, when evaluating the collateral ligaments of the distal interphalangeal joint on images acquired with a high-field MR imaging system that has a horizontally oriented main magnetic field.
引用
收藏
页码:2 / 10
页数:9
相关论文
共 19 条
  • [1] MR imaging of the carpal tunnel
    Allmann, KH
    Horch, R
    Uhl, M
    Gufler, H
    Altehoefer, C
    Stark, GB
    Langer, M
    [J]. EUROPEAN JOURNAL OF RADIOLOGY, 1997, 25 (02) : 141 - 145
  • [2] Effect of deep digital flexor tendon orientation on magnetic resonance imaging signal intensity in isolated equine limbs - The magic angle effect
    Busoni, V
    Snaps, F
    [J]. VETERINARY RADIOLOGY & ULTRASOUND, 2002, 43 (05) : 428 - 430
  • [3] Chappell KE, 2004, AM J NEURORADIOL, V25, P431
  • [4] Magnetic resonance imaging evaluation of 264 horses with foot pain: The podotrochlear apparatus, deep digital flexor tendon and collateral ligaments of the distal interphalangeal joint
    Dyson, S.
    Murray, R.
    [J]. EQUINE VETERINARY JOURNAL, 2007, 39 (04) : 340 - 343
  • [5] Dyson S. J., 2004, Proceedings of the 50th Annual Convention of the American Association of Equine Practitioners, Denver, Colorado, USA, 4-8 December, 2004, P248
  • [6] Collateral desmitis of the distal interphalangeal joint in 18 horses (2001-2002)
    Dyson, SJ
    Murray, R
    Schramme, M
    Branch, M
    [J]. EQUINE VETERINARY JOURNAL, 2004, 36 (02) : 160 - 166
  • [7] EFFECT OF TENDON ORIENTATION ON MR IMAGING SIGNAL INTENSITY - A MANIFESTATION OF THE MAGIC ANGLE PHENOMENON
    ERICKSON, SJ
    COX, IH
    HYDE, JS
    CARRERA, GF
    STRANDT, JA
    ESTKOWSKI, LD
    [J]. RADIOLOGY, 1991, 181 (02) : 389 - 392
  • [8] THE MAGIC-ANGLE EFFECT - BACKGROUND PHYSICS AND CLINICAL RELEVANCE
    ERICKSON, SJ
    PROST, RW
    TIMINS, ME
    [J]. RADIOLOGY, 1993, 188 (01) : 23 - 25
  • [9] Magnetic resonance imaging of short T2 components in tissue
    Gatehouse, PD
    Bydder, GM
    [J]. CLINICAL RADIOLOGY, 2003, 58 (01) : 1 - 19
  • [10] Hayes CW, 1996, TOP MAGN RESON IMAG, V8, P51