Orbital form analysis: problems with design and positioning of precontoured orbital implants A serial study using post-processed clinical CT data in unaffected orbits

被引:44
作者
Kamer, L. [1 ]
Noser, H. [1 ]
Schramm, A. [2 ]
Hammer, B. [3 ]
机构
[1] AO Res Inst Davos, CH-7270 Davos, Switzerland
[2] Univ Ulm, Acad Hosp, Mil Hosp Ulm, Dept Oral & Maxillofacial Surg Plast & Esthet Fac, D-89069 Ulm, Germany
[3] Hirslanden Med Ctr, Cfc Hirslanden Cranio Facial Ctr, Aarau, Switzerland
关键词
orbital fracture; precontoured implant; computed tomography; three-dimensional bone models; statistical form analysis; SHAPE MODELS; FRACTURES; BONE;
D O I
10.1016/j.ijom.2010.03.005
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Inter-individual size and shape (form) variation for the orbital floor and medial wall was assessed and compared with its posterior partition. Reconstruction of the posterior partition is known to be a surgical challenge in complex orbital defect repair when using standard manual implant contouring and positioning techniques. The size variation of both regions was assessed, alone and combined, in statistical form analysis using three-dimensional computer models of left and mirrored right orbits, obtained from 70 clinical computed tomography (CT) scans of adult European Caucasians with unaffected orbits. Major shape and size variability for both regions was observed, but to a larger extent for the entire orbital floor and medial wall, with males having significantly larger regions but with no differing shape patterns. Statistical modeling was used to identify characteristic shape patterns in given orbits. The size, shape and positioning of precontoured implants are decisive criteria for the adequate repair of complex orbital defects. The results indicate that optimal form conditions for prefabricated implants exist in a restricted area corresponding to the transition of the posterior orbital floor and medial wall.
引用
收藏
页码:666 / 672
页数:7
相关论文
共 18 条
  • [1] Bookstein F. L., 1997, MORPHOMETRIC TOOLS L
  • [2] ACTIVE SHAPE MODELS - THEIR TRAINING AND APPLICATION
    COOTES, TF
    TAYLOR, CJ
    COOPER, DH
    GRAHAM, J
    [J]. COMPUTER VISION AND IMAGE UNDERSTANDING, 1995, 61 (01) : 38 - 59
  • [3] Dolynchuk K N, 1996, J Craniomaxillofac Trauma, V2, P56
  • [4] Surface parameterization: a tutorial and survey
    Floater, MS
    Hormann, K
    [J]. ADVANCES IN MULTIRESOLUTION FOR GEOMETRIC MODELLING, 2005, : 157 - 186
  • [5] Hammer B., 1995, Orbital fractures: diagnosis, operative treatment
  • [6] Intraoperative imaging of zygomaticomaxillary complex fractures using a 3D C-arm system
    Heiland, M
    Schulze, D
    Blake, F
    Schmelzle, R
    [J]. INTERNATIONAL JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2005, 34 (04) : 369 - 375
  • [7] A 3D statistical shape model of the pelvic bone for segmentation
    Lamecker, H
    Seebass, M
    Hege, HC
    Deuflhard, P
    [J]. MEDICAL IMAGING 2004: IMAGE PROCESSING, PTS 1-3, 2004, 5370 : 1341 - 1351
  • [8] LAMECKER H, 2007, P 4 INT C COMP AID S
  • [9] Mardia, 1998, STAT SHAPE ANAL WILE
  • [10] Anatomical 3-dimensional pre-bent titanium implant for orbital floor fractures
    Metzger, Marc C.
    Schoen, Ralf
    Weyer, Nils
    Rafii, Amir
    Gellrich, Nils-Claudius
    Schmelzeisen, Rainer
    Strong, Bradley E.
    [J]. OPHTHALMOLOGY, 2006, 113 (10) : 1863 - 1868