Primary and Secondary Stability of Single Short Implants

被引:14
作者
Alonso, Fernando R. [1 ]
Triches, Diego F. [1 ]
Mezzomo, Luis A. M. [2 ]
Teixeira, Eduardo R. [1 ]
Shinkai, Rosemary S. A. [1 ]
机构
[1] Pontificia Univ Catolica Rio Grande do Sul, Dept Prosthodont, Porto Alegre, RS, Brazil
[2] Univ Fed Santa Catarina, Dent Sch, Florianopolis, SC, Brazil
关键词
Bone quality; primary stability; secondary stability; single short implants; RESONANCE FREQUENCY-ANALYSIS; DAMPING CAPACITY ASSESSMENT; SHORT DENTAL IMPLANTS; IN-VITRO; FOLLOW-UP; BONE; SURFACE; LENGTH; METAANALYSIS; SURVIVAL;
D O I
10.1097/SCS.0000000000004567
中图分类号
R61 [外科手术学];
学科分类号
摘要
Purpose: This prospective cohort study assessed the effect of bone quality on the primary and secondary stability of single short implants placed in the posterior region. Materials and Methods: A total of 39 short implants (4.1 x 6-nun long) were placed in the posterior region of the maxilla or mandible in 18 patients. Bone quality was classified into type I, II, III, or IV as assessed intrasurgically. Primary implant stability was measured with insertion torque, damping capacity (PTV values), and resonance frequency analysis (ISQ values). Secondary stability was measured by ISQ and PTV at abutment installation. Data were analyzed by using repeated-measures ANOVA and Tukey's test, Kruslcall -Wallis test, and Spearman correlation tests. Results: Implants placed in bone type IV had significant lower insertion torque and ISQ values as well as higher PTV values than in bone types Ito II (P < 0.05). The mean ISQ values were higher at abutment installation than at implant placement (P < 0.05), regardless the bone type. The assessment methods of implant stability showed a moderate correlation. Conclusions: Bone quality influences both the primary and secondary stability of single short implants in the posterior region.
引用
收藏
页码:E548 / E551
页数:5
相关论文
共 25 条
[21]   Factors influencing resonance frequency analysis assessed by Osstell™mentor during implant tissue integration: I. Instrument positioning, bone structure, implant length [J].
Sim, Christina P. C. ;
Lang, Niklaus P. .
CLINICAL ORAL IMPLANTS RESEARCH, 2010, 21 (06) :598-604
[22]   Influence of the surgical technique and surface roughness on the primary stability of an implant in artificial bone with a density equivalent to maxillary bone: a laboratory study [J].
Tabassum, Afsheen ;
Meijer, Gert J. ;
Wolke, Johannes G. C. ;
Jansen, John A. .
CLINICAL ORAL IMPLANTS RESEARCH, 2009, 20 (04) :327-332
[23]   Primary stability, insertion torque and bone density of cylindric implant ad modum Branemark: Is there a relationship? An in vitro study [J].
Trisi, Paolo ;
De Benedittis, Simona ;
Perfetti, Giorgio ;
Berardi, Davide .
CLINICAL ORAL IMPLANTS RESEARCH, 2011, 22 (05) :567-570
[24]   Implant Insertional Torque Values Predict Outcomes [J].
Walker, Lee R. ;
Morris, Gary A. ;
Novotny, Paul J. .
JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2011, 69 (05) :1344-1349
[25]  
Zix J, 2008, INT J ORAL MAX IMPL, V23, P525