Primary and Secondary Stability of Single Short Implants

被引:14
作者
Alonso, Fernando R. [1 ]
Triches, Diego F. [1 ]
Mezzomo, Luis A. M. [2 ]
Teixeira, Eduardo R. [1 ]
Shinkai, Rosemary S. A. [1 ]
机构
[1] Pontificia Univ Catolica Rio Grande do Sul, Dept Prosthodont, Porto Alegre, RS, Brazil
[2] Univ Fed Santa Catarina, Dent Sch, Florianopolis, SC, Brazil
关键词
Bone quality; primary stability; secondary stability; single short implants; RESONANCE FREQUENCY-ANALYSIS; DAMPING CAPACITY ASSESSMENT; SHORT DENTAL IMPLANTS; IN-VITRO; FOLLOW-UP; BONE; SURFACE; LENGTH; METAANALYSIS; SURVIVAL;
D O I
10.1097/SCS.0000000000004567
中图分类号
R61 [外科手术学];
学科分类号
摘要
Purpose: This prospective cohort study assessed the effect of bone quality on the primary and secondary stability of single short implants placed in the posterior region. Materials and Methods: A total of 39 short implants (4.1 x 6-nun long) were placed in the posterior region of the maxilla or mandible in 18 patients. Bone quality was classified into type I, II, III, or IV as assessed intrasurgically. Primary implant stability was measured with insertion torque, damping capacity (PTV values), and resonance frequency analysis (ISQ values). Secondary stability was measured by ISQ and PTV at abutment installation. Data were analyzed by using repeated-measures ANOVA and Tukey's test, Kruslcall -Wallis test, and Spearman correlation tests. Results: Implants placed in bone type IV had significant lower insertion torque and ISQ values as well as higher PTV values than in bone types Ito II (P < 0.05). The mean ISQ values were higher at abutment installation than at implant placement (P < 0.05), regardless the bone type. The assessment methods of implant stability showed a moderate correlation. Conclusions: Bone quality influences both the primary and secondary stability of single short implants in the posterior region.
引用
收藏
页码:E548 / E551
页数:5
相关论文
共 25 条
  • [1] Horizontal and Vertical Ridge Augmentation in Localized Alveolar Deficient Sites: A Retrospective Case Series
    Annibali, Susanna
    Bignozzi, Isabella
    Sammartino, Gilberto
    La Monaca, Gerardo
    Cristalli, Maria Paola
    [J]. IMPLANT DENTISTRY, 2012, 21 (03) : 175 - 185
  • [2] Validity and clinical significance of biomechanical testing of implant/bone interface
    Aparicio, Carlos
    Lang, Niklaus R.
    Rangert, Bo
    [J]. CLINICAL ORAL IMPLANTS RESEARCH, 2006, 17 : 2 - 7
  • [3] De Santis D, 2011, INT J ORAL MAX IMPL, V26, P393
  • [4] Degidi M, 2010, INT J ORAL MAX IMPL, V25, P558
  • [5] Management of Limited Vertical Bone Height in the Posterior Mandible: Short Dental Implants Versus Nerve Lateralization With Standard Length Implants
    Dursun, Erhan
    Keceli, Huseyin Gencay
    Uysal, Serdar
    Gungor, Hamiyet
    Muhtarogullari, Mehmet
    Tozum, Tolga Fikret
    [J]. JOURNAL OF CRANIOFACIAL SURGERY, 2016, 27 (03) : 578 - 585
  • [6] Gonçalves Thais Marques Simek Vega, 2015, Braz. Dent. J., V26, P325, DOI 10.1590/0103-6440201300265
  • [7] Resonance frequency analysis and damping capacity assessment -: Part I:: an in vitro study on measurement reliability and a method of comparison in the determination of primary dental implant stability
    Lachmann, S
    Jäger, B
    Axmann, D
    Gomez-Roman, G
    Groten, M
    Weber, H
    [J]. CLINICAL ORAL IMPLANTS RESEARCH, 2006, 17 (01) : 75 - 79
  • [8] Lin IC, 2011, INT J ORAL MAX IMPL, V26, P1079
  • [9] Meta-analysis of single crowns supported by short (&lt;10 mm) implants in the posterior region
    Mezzomo, Luis Andre
    Miller, Rodrigo
    Triches, Diego
    Alonso, Fernando
    Shinkai, Rosemary Sadami A.
    [J]. JOURNAL OF CLINICAL PERIODONTOLOGY, 2014, 41 (02) : 191 - 213
  • [10] Are Short Dental Implants (&lt;10 mm) Effective? A Meta-Analysis on Prospective Clinical Trials
    Monje, Alberto
    Chan, Hsun-Liang
    Fu, Jia-Hui
    Suarez, Fernando
    Galindo-Moreno, Pablo
    Wang, Hom-Lay
    [J]. JOURNAL OF PERIODONTOLOGY, 2013, 84 (07) : 895 - 904