Robustness of end-systolic reconstructions in coronary dual-source CT angiography for high heart rate patients

被引:48
|
作者
Adler, Ghazal [3 ]
Meille, Laurent [3 ]
Rohnean, Adela [3 ]
Sigal-Cinqualbre, Anne [3 ]
Capderou, Andre [2 ]
Paul, Jean-Francois [1 ,3 ]
机构
[1] Ctr Chirurg Marie Lannelongue, Serv Radiol, F-92350 Le Plessis Robinson, France
[2] Ctr Chirurg Marie Lannelongue, Physiol UMR 8162, F-92350 Le Plessis Robinson, France
[3] Ctr Chirurg Marie Lannelongue, Dept Radiol, F-92350 Le Plessis Robinson, France
关键词
Heart rate; Coronary vessels; Computed tomography; Spiral; Cardiac gated imaging techniques; SOURCE COMPUTED-TOMOGRAPHY; IMPROVE IMAGE QUALITY; DIAGNOSTIC-ACCURACY; INITIAL-EXPERIENCE; RATE-VARIABILITY; 1ST EXPERIENCE; CARDIAC CYCLE; ARTERIES; MOTION; OPTIMIZATION;
D O I
10.1007/s00330-009-1642-9
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Reconstruction of cardiac computed tomography (CT) images is challenging when the heart rate is higher than 65 beats per minute (bpm). The optimal reconstruction time is often found to be at the end-systolic phase, but image quality remains uncertain. Using dual-source (DS) CT and 83-ms temporal resolution, we evaluated the robustness of the temporal window with low motion during the end systole. We studied 41 DSCT in consecutive patients with a heart rate > 65 bpm. Eleven systolic reconstructions were performed every 20 ms between 200 ms and 400 ms of the R-R interval. The end-systolic temporal window (ESTW) was defined as the interval between the first and last selected phases judged adequate for diagnosis. Heart rates varied from 67 to 150 bpm. ESTW was always to be found greater than 100 ms. The mean ESTW was 178 ms (SD: 57 ms), and varied independently of heart rate. All data sets achieved diagnostic quality during the end-systolic phase at a time point between 35 and 50% of the R-R interval. Our data suggest that CT with a temporal window below 100 ms may provide acceptable systolic reconstructions at any heart rate, in a large proportion of patients.
引用
收藏
页码:1118 / 1123
页数:6
相关论文
共 50 条
  • [41] Myocardial Bridging of the Left Anterior Descending Coronary Artery: Depiction Rate and Morphologic Features by Dual-Source CT Coronary Angiography
    Hwang, Jin Ho
    Ko, Sung Min
    Roh, Hong Gee
    Song, Meong Gun
    Shin, Je Kyoun
    Chee, Hyun Kun
    Kim, Joon Suk
    KOREAN JOURNAL OF RADIOLOGY, 2010, 11 (05) : 514 - 521
  • [42] Impact of heart rate on coronary computed tomographic angiography interpretability with a third-generation dual-source scanner
    Miller, Robert J. H.
    Eisenberg, Evann
    Friedman, John
    Cheng, Victor
    Hayes, Sean
    Tamarappoo, Balaji
    Thomson, Louise
    Berman, Daniel S.
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2019, 295 : 42 - 47
  • [43] Contrast material injection protocol with the flow rate adjusted to the heart rate for dual source CT coronary angiography
    Zhu, Xiaomei
    Chen, Wenping
    Li, Mei
    Xu, Yi
    Xu, Hai
    Zhu, Yinsu
    Wang, Dehang
    Tang, Lijun
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2012, 28 (06) : 1557 - 1565
  • [44] Effectiveness of Using Dual-source CT and the Upshot it creates on Both Heart Rate and Image Quality
    Selcuk, Tuba
    Otcu, Hafize
    Yuceler, Zeyneb
    Bilgili, Cigdem
    Bulakci, Mesut
    Savas, Yildiray
    Celik, Omer
    BALKAN MEDICAL JOURNAL, 2016, 33 (03) : 283 - 293
  • [45] Strengths and limitations of coronary angiography with turbo high-pitch third-generation dual-source CT
    Ochs, M. M.
    Andre, F.
    Korosoglou, G.
    Fritz, T.
    Seitz, S.
    Bogomazov, Y.
    Schlett, C. L.
    Sokiranski, R.
    Sommer, A.
    Gueckel, F.
    Brado, M.
    Kauczor, H. -U.
    Goerich, J.
    Buss, S. J.
    CLINICAL RADIOLOGY, 2017, 72 (09) : 739 - 744
  • [46] Adaptive prospective ECG-triggered sequence coronary angiography in dual-source CT without heart rate control: Image quality and diagnostic performance
    Pan, Chang-Jie
    Qian, Nong
    Wang, Tao
    Tang, Xiao-Qiang
    Xue, Yue-Jun
    EXPERIMENTAL AND THERAPEUTIC MEDICINE, 2013, 5 (02) : 636 - 642
  • [47] High-pitch dual-source CT coronary angiography with low volumes of contrast medium
    Alexander Lembcke
    Carsten Schwenke
    Patrick A. Hein
    Gesine Knobloch
    Tahir Durmus
    Bernd Hamm
    Alexander Huppertz
    European Radiology, 2014, 24 : 120 - 127
  • [48] High-pitch coronary CT angiography in dual-source CT during free breathing vs. breath holding in patients with low heart rates
    Bischoff, Bernhard
    Meinel, Felix G.
    Del Prete, Alessandra
    Reiser, Maximilian F.
    Becker, Hans-Christoph
    EUROPEAN JOURNAL OF RADIOLOGY, 2013, 82 (12) : 2217 - 2221
  • [49] Dual-source CT versus single-source 64-section CT angiography for coronary artery disease: A meta-analysis
    Jiang, B.
    Wang, J.
    Lv, X.
    Cai, W.
    CLINICAL RADIOLOGY, 2014, 69 (08) : 861 - 869
  • [50] Coronary CT angiography in obese patients using 3rd generation dual-source CT: effect of body mass index on image quality
    Mangold, Stefanie
    Wichmann, Julian L.
    Schoepf, U. Joseph
    Litwin, Sheldon E.
    Canstein, Christian
    Varga-Szemes, Akos
    Muscogiuri, Giuseppe
    Fuller, Stephen R.
    Stubenrauch, Andrew C.
    Nikolaou, Konstantin
    De Cecco, Carlo N.
    EUROPEAN RADIOLOGY, 2016, 26 (09) : 2937 - 2946