Robustness of end-systolic reconstructions in coronary dual-source CT angiography for high heart rate patients

被引:48
|
作者
Adler, Ghazal [3 ]
Meille, Laurent [3 ]
Rohnean, Adela [3 ]
Sigal-Cinqualbre, Anne [3 ]
Capderou, Andre [2 ]
Paul, Jean-Francois [1 ,3 ]
机构
[1] Ctr Chirurg Marie Lannelongue, Serv Radiol, F-92350 Le Plessis Robinson, France
[2] Ctr Chirurg Marie Lannelongue, Physiol UMR 8162, F-92350 Le Plessis Robinson, France
[3] Ctr Chirurg Marie Lannelongue, Dept Radiol, F-92350 Le Plessis Robinson, France
关键词
Heart rate; Coronary vessels; Computed tomography; Spiral; Cardiac gated imaging techniques; SOURCE COMPUTED-TOMOGRAPHY; IMPROVE IMAGE QUALITY; DIAGNOSTIC-ACCURACY; INITIAL-EXPERIENCE; RATE-VARIABILITY; 1ST EXPERIENCE; CARDIAC CYCLE; ARTERIES; MOTION; OPTIMIZATION;
D O I
10.1007/s00330-009-1642-9
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Reconstruction of cardiac computed tomography (CT) images is challenging when the heart rate is higher than 65 beats per minute (bpm). The optimal reconstruction time is often found to be at the end-systolic phase, but image quality remains uncertain. Using dual-source (DS) CT and 83-ms temporal resolution, we evaluated the robustness of the temporal window with low motion during the end systole. We studied 41 DSCT in consecutive patients with a heart rate > 65 bpm. Eleven systolic reconstructions were performed every 20 ms between 200 ms and 400 ms of the R-R interval. The end-systolic temporal window (ESTW) was defined as the interval between the first and last selected phases judged adequate for diagnosis. Heart rates varied from 67 to 150 bpm. ESTW was always to be found greater than 100 ms. The mean ESTW was 178 ms (SD: 57 ms), and varied independently of heart rate. All data sets achieved diagnostic quality during the end-systolic phase at a time point between 35 and 50% of the R-R interval. Our data suggest that CT with a temporal window below 100 ms may provide acceptable systolic reconstructions at any heart rate, in a large proportion of patients.
引用
收藏
页码:1118 / 1123
页数:6
相关论文
共 50 条
  • [31] Dual-Source Computed Tomographic Coronary Angiography Image Quality and Stenosis Diagnosis in Patients with High Heart Rates
    Zheng, Minwen
    Li, Jiayi
    Xu, Jian
    Chen, Kang
    Zhao, Hongliang
    Huan, Yi
    TEXAS HEART INSTITUTE JOURNAL, 2009, 36 (02): : 117 - 124
  • [32] High-pitch dual-source CT coronary angiography with low volumes of contrast medium
    Lembcke, Alexander
    Schwenke, Carsten
    Hein, Patrick A.
    Knobloch, Gesine
    Durmus, Tahir
    Hamm, Bernd
    Huppertz, Alexander
    EUROPEAN RADIOLOGY, 2014, 24 (01) : 120 - 127
  • [33] Performance of turbo high-pitch dual-source CT for coronary CT angiography: first ex vivo and patient experience
    Morsbach, Fabian
    Gordic, Sonja
    Desbiolles, Lotus
    Husarik, Daniela
    Frauenfelder, Thomas
    Schmidt, Bernhard
    Allmendinger, Thomas
    Wildermuth, Simon
    Alkadhi, Hatem
    Leschka, Sebastian
    EUROPEAN RADIOLOGY, 2014, 24 (08) : 1889 - 1895
  • [34] Correlation of radiation dose and heart rate in dual-source computed tomography coronary angiography
    Laspas, Fotios
    Tsantioti, Dimitra
    Roussakis, Arkadios
    Kritikos, Nikolaos
    Efthimiadou, Roxani
    Kehagias, Dimitrios
    Andreou, John
    ACTA RADIOLOGICA, 2011, 52 (03) : 273 - 277
  • [35] Diagnostic accuracy of dual-source CT coronary angiography in patients with atrial fibrillation: Meta analysis
    Sun, Gang
    Li, Min
    Jiang, Zhi-wei
    Xu, Lin
    Peng, Zhao-hui
    Ding, Juan
    Li, Li
    Jin, Zhi-tao
    EUROPEAN JOURNAL OF RADIOLOGY, 2013, 82 (10) : 1749 - 1754
  • [36] Dual-source CT coronary angiography: prospective versus retrospective acquisition technique
    De Cecco, C. N.
    Buffa, V.
    Fedeli, S.
    Vallone, A.
    Ruopoli, R.
    Luzietti, M.
    Miele, V.
    Enrici, M. Maurizi
    Musumeci, F.
    David, V.
    RADIOLOGIA MEDICA, 2011, 116 (02): : 178 - 188
  • [37] Diagnostic accuracy of dual-source CT coronary angiography: The effect of average heart rate, heart rate variability, and calcium score in a clinical perspective
    Zhang, Long-Jiang
    Wu, Sheng-Yong
    Wang, Jing
    Lu, Ying
    Zhang, Zhuo-Li
    Jiang, Shi-Sen
    Zhou, Chang-Sheng
    Lu, Guang-Ming
    ACTA RADIOLOGICA, 2010, 51 (07) : 727 - 740
  • [38] Systolic acquisition of coronary dual-source computed tomography angiography: feasibility in an unselected patient population
    Bamberg, Fabian
    Sommer, Wieland H.
    Schenzle, Jan C.
    Becker, Christoph R.
    Nikolaou, Konstantin
    Reiser, Maximilian F.
    Johnson, Thorsten R. C.
    EUROPEAN RADIOLOGY, 2010, 20 (06) : 1331 - 1336
  • [39] Assessment of image quality of 64-row Dual Source versus Single Source CT coronary angiography on heart rate: A phantom study
    Dikkers, R.
    Greuter, M. J. W.
    Kristanto, W.
    van Ooijen, P. M. A.
    Sijens, P. E.
    Willems, T. P.
    Oudkerk, M.
    EUROPEAN JOURNAL OF RADIOLOGY, 2009, 70 (01) : 61 - 68
  • [40] Diagnostic accuracy of dual-source CT coronary angiography in a population unselected for degree of coronary artery calcification and without heart rate modification
    Lin, C-J.
    Hsu, J. -C.
    Lai, Y. J.
    Wang, K-L
    Lee, J. -Y.
    Li, A. -H.
    Chu, S. -H.
    CLINICAL RADIOLOGY, 2010, 65 (02) : 109 - 117