Robustness of end-systolic reconstructions in coronary dual-source CT angiography for high heart rate patients

被引:48
|
作者
Adler, Ghazal [3 ]
Meille, Laurent [3 ]
Rohnean, Adela [3 ]
Sigal-Cinqualbre, Anne [3 ]
Capderou, Andre [2 ]
Paul, Jean-Francois [1 ,3 ]
机构
[1] Ctr Chirurg Marie Lannelongue, Serv Radiol, F-92350 Le Plessis Robinson, France
[2] Ctr Chirurg Marie Lannelongue, Physiol UMR 8162, F-92350 Le Plessis Robinson, France
[3] Ctr Chirurg Marie Lannelongue, Dept Radiol, F-92350 Le Plessis Robinson, France
关键词
Heart rate; Coronary vessels; Computed tomography; Spiral; Cardiac gated imaging techniques; SOURCE COMPUTED-TOMOGRAPHY; IMPROVE IMAGE QUALITY; DIAGNOSTIC-ACCURACY; INITIAL-EXPERIENCE; RATE-VARIABILITY; 1ST EXPERIENCE; CARDIAC CYCLE; ARTERIES; MOTION; OPTIMIZATION;
D O I
10.1007/s00330-009-1642-9
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Reconstruction of cardiac computed tomography (CT) images is challenging when the heart rate is higher than 65 beats per minute (bpm). The optimal reconstruction time is often found to be at the end-systolic phase, but image quality remains uncertain. Using dual-source (DS) CT and 83-ms temporal resolution, we evaluated the robustness of the temporal window with low motion during the end systole. We studied 41 DSCT in consecutive patients with a heart rate > 65 bpm. Eleven systolic reconstructions were performed every 20 ms between 200 ms and 400 ms of the R-R interval. The end-systolic temporal window (ESTW) was defined as the interval between the first and last selected phases judged adequate for diagnosis. Heart rates varied from 67 to 150 bpm. ESTW was always to be found greater than 100 ms. The mean ESTW was 178 ms (SD: 57 ms), and varied independently of heart rate. All data sets achieved diagnostic quality during the end-systolic phase at a time point between 35 and 50% of the R-R interval. Our data suggest that CT with a temporal window below 100 ms may provide acceptable systolic reconstructions at any heart rate, in a large proportion of patients.
引用
收藏
页码:1118 / 1123
页数:6
相关论文
共 50 条
  • [21] Submillisievert coronary CT angiography with adaptive prospective ECG-triggered sequence acquisition and iterative reconstruction in patients with high heart rate on the dual-source CT
    Tang, Pei-Hua
    Du, Ben-Jun
    Fang, Xiang-Ming
    Hu, Xiao-Yun
    Qian, Ping-Yan
    Gao, Quan-Sheng
    JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY, 2016, 24 (06) : 807 - 820
  • [22] Automatic selection of optimal systolic and diastolic reconstruction windows for dual-source CT coronary angiography
    Seifarth, H.
    Puesken, M.
    Wienbeck, S.
    Maintz, D.
    Fischbach, R.
    Heindel, W.
    Juergens, K. -U.
    EUROPEAN RADIOLOGY, 2009, 19 (07) : 1645 - 1652
  • [23] Detection of coronary artery anomalies by dual-source CT coronary angiography
    Cheng, Z.
    Wang, X.
    Duan, Y.
    Wu, L.
    Wu, D.
    Liang, C.
    Liu, C.
    Xu, Z.
    CLINICAL RADIOLOGY, 2010, 65 (10) : 815 - 822
  • [24] Diagnostic accuracy of dual-source CT coronary angiography with prospective ECG-triggering on different heart rate patients
    Ming-li Sun
    Bin Lu
    Run-ze Wu
    Laura Johnson
    Lei Han
    Gang Liu
    Fang-Fang Yu
    Zhi-hui Hou
    Yang Gao
    Hong-yu Wang
    Shiliang Jiang
    Yue-jin Yang
    Shu-bin Qiao
    European Radiology, 2011, 21 : 1635 - 1642
  • [25] Diagnostic Value of 64-Slice Dual-Source CT Coronary Angiography in Patients with Atrial Fibrillation: Comparison with Invasive Coronary Angiography
    Zhang, Jian-Jun
    Liu, Tie
    Feng, Yue
    Wu, Wei-Feng
    Mou, Cai-Yun
    Zhai, Li-Hao
    KOREAN JOURNAL OF RADIOLOGY, 2011, 12 (04) : 416 - 423
  • [26] Systolic prospectively ECG-triggered dual-source CT angiography for evaluation of the coronary arteries in heart transplant recipients
    Gorka Bastarrika
    Jordi Broncano
    María Arraiza
    Pedro M. Azcárate
    Isabel Simon-Yarza
    Beltrán G. Levy Praschker
    Jesús C. Pueyo
    José L. Zubieta
    Gregorio Rabago
    European Radiology, 2011, 21 : 1887 - 1894
  • [27] Dual-source CT for visualization of the coronary arteries in heart transplant patients with high heart rates
    Bastarrika, Gorka
    Nicola De Cecco, Carlo
    Arraiza, Maria
    Mastrobuoni, Stefano
    Pueyo, Jesus C.
    Ubilla, Matias
    Rabago, Gregorio
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2008, 191 (02) : 448 - 454
  • [28] Comparison of dual-source ct coronary angiography and conventional coronary angiography for detecting coronary artery disease
    Xu, Yi
    Tang, Lijun
    Zhu, Xiaomei
    Xu, Hai
    Tang, Jinhua
    Yang, Zhijian
    Wang, Liansheng
    Wang, Dehang
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2010, 26 : 75 - 81
  • [29] Diagnostic performance of dual-source CT coronary angiography with and without heart rate control: Systematic review and meta-analysis
    Li, M.
    Zhang, G. -M.
    Zhao, J. -S.
    Jiang, Z. -W.
    Peng, Z. -H.
    Jin, Z. -T.
    Sun, G.
    CLINICAL RADIOLOGY, 2014, 69 (02) : 163 - 171
  • [30] Subtraction coronary CT angiography in patients with high heart rate
    Zhou, Bi
    Tang, Zhuoyue
    Huang, Xianlong
    Zhu, Hongzhang
    Li, Xiaojiao
    Xiong, Hua
    Yu, Jiayi
    Liao, Ruikun
    Zhang, Dan
    ACTA CARDIOLOGICA, 2023, 78 (01) : 99 - 108