Robustness of end-systolic reconstructions in coronary dual-source CT angiography for high heart rate patients

被引:49
作者
Adler, Ghazal [3 ]
Meille, Laurent [3 ]
Rohnean, Adela [3 ]
Sigal-Cinqualbre, Anne [3 ]
Capderou, Andre [2 ]
Paul, Jean-Francois [1 ,3 ]
机构
[1] Ctr Chirurg Marie Lannelongue, Serv Radiol, F-92350 Le Plessis Robinson, France
[2] Ctr Chirurg Marie Lannelongue, Physiol UMR 8162, F-92350 Le Plessis Robinson, France
[3] Ctr Chirurg Marie Lannelongue, Dept Radiol, F-92350 Le Plessis Robinson, France
关键词
Heart rate; Coronary vessels; Computed tomography; Spiral; Cardiac gated imaging techniques; SOURCE COMPUTED-TOMOGRAPHY; IMPROVE IMAGE QUALITY; DIAGNOSTIC-ACCURACY; INITIAL-EXPERIENCE; RATE-VARIABILITY; 1ST EXPERIENCE; CARDIAC CYCLE; ARTERIES; MOTION; OPTIMIZATION;
D O I
10.1007/s00330-009-1642-9
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Reconstruction of cardiac computed tomography (CT) images is challenging when the heart rate is higher than 65 beats per minute (bpm). The optimal reconstruction time is often found to be at the end-systolic phase, but image quality remains uncertain. Using dual-source (DS) CT and 83-ms temporal resolution, we evaluated the robustness of the temporal window with low motion during the end systole. We studied 41 DSCT in consecutive patients with a heart rate > 65 bpm. Eleven systolic reconstructions were performed every 20 ms between 200 ms and 400 ms of the R-R interval. The end-systolic temporal window (ESTW) was defined as the interval between the first and last selected phases judged adequate for diagnosis. Heart rates varied from 67 to 150 bpm. ESTW was always to be found greater than 100 ms. The mean ESTW was 178 ms (SD: 57 ms), and varied independently of heart rate. All data sets achieved diagnostic quality during the end-systolic phase at a time point between 35 and 50% of the R-R interval. Our data suggest that CT with a temporal window below 100 ms may provide acceptable systolic reconstructions at any heart rate, in a large proportion of patients.
引用
收藏
页码:1118 / 1123
页数:6
相关论文
共 28 条
[1]   Contrast-enhanced coronary artery visualization by dual-source computed tomography - Initial experience [J].
Achenbach, S ;
Ropers, D ;
Kuettner, A ;
Flohr, T ;
Ohnesorge, B ;
Bruder, H ;
Theessen, H ;
Karakaya, M ;
Daniel, WG ;
Bautz, W ;
Kalender, WA ;
Anders, K .
EUROPEAN JOURNAL OF RADIOLOGY, 2006, 57 (03) :331-335
[2]   Optimal image reconstruction phase at low and high heart rates in dual-source CT coronary angiography [J].
Araoz, Philip A. ;
Kirsch, Jacobo ;
Primak, Andrew N. ;
Braun, Natalie N. ;
Saba, Osama ;
Williamson, Eric E. ;
Harmsen, W. Scott ;
Mandrekar, Jayawant N. ;
McCollough, Cynthia H. .
INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2009, 25 (08) :837-845
[3]   LINEAR RELATIONSHIP BETWEEN ELECTRICAL SYSTOLE, MECHANICAL SYSTOLE, AND HEART-RATE [J].
BOUDOULAS, H ;
GELERIS, P ;
LEWIS, RP ;
RITTGERS, SE .
CHEST, 1981, 80 (05) :613-618
[4]   Dual-source CT: effect of heart rate, heart rate variability, and calcification on image quality and diagnostic accuracy [J].
Brodoefel, Harald ;
Burgstahler, Christof ;
Tsiflikas, Ilias ;
Reimann, Anja ;
Schroeder, Stephen ;
Claussen, Claus D. ;
Heuschmid, Martin ;
Kopp, Andreas F. .
RADIOLOGY, 2008, 247 (02) :346-355
[5]   Duration of diastole and its phases as a function of heart rate during supine bicycle exercise [J].
Chung, CS ;
Karamanoglu, M ;
Kovács, SJ .
AMERICAN JOURNAL OF PHYSIOLOGY-HEART AND CIRCULATORY PHYSIOLOGY, 2004, 287 (05) :H2003-H2008
[6]   Influence of heart rate on diagnostic accuracy and image quality of 16-slice CT coronary angiography: Comparison of multisegment and halfscan reconstruction approaches [J].
Marc Dewey ;
Florian Teige ;
Michael Laule ;
Bernd Hamm .
European Radiology, 2007, 17 (11) :2829-2837
[7]  
Halliburton SS, 2003, HERZ, V28, P20, DOI 10.1007/s00059-003-2445-4
[8]   Multi-detector row CT coronary angiography: Influence of reconstruction technique and heart rate on image quality [J].
Herzog, C ;
Arning-Erb, M ;
Zangos, S ;
Eichler, K ;
Hammerstingl, R ;
Dogan, S ;
Ackermann, H ;
Vogl, TJ .
RADIOLOGY, 2006, 238 (01) :75-86
[9]   Heart-rate-adapted image reconstruction in multidetector-row cardiac CT: influence of physiological and technical prerequisite on image quality [J].
Herzog, C ;
Abolmaali, N ;
Balzer, JO ;
Baunach, S ;
Ackermann, H ;
Dogan, S ;
Britten, MB ;
Vogl, TJ .
EUROPEAN RADIOLOGY, 2002, 12 (11) :2670-2678
[10]   Does two-segment image reconstruction at 64-section CT coronary angiography improve image quality and diagnostic accuracy? [J].
Herzog, Christopher ;
Nguyen, Shaun A. ;
Savino, Giancarlo ;
Zwerner, Peter L. ;
Doll, Josh ;
Nielsen, Christopher D. ;
Flohr, Thomas G. ;
Vogl, Thomas J. ;
Costello, Philip ;
Schoepf, U. Joseph .
RADIOLOGY, 2007, 244 (01) :121-129