Optimization of dispersive liquid-liquid microextraction of Co(II) and Fe(III) as their oxinate chelates and analysis by HPLC: Application for the simultaneous determination of Co(II) and Fe(III) in water samples

被引:29
作者
Farajzadeh, Mir Ali [1 ]
Bahram, Morteza [2 ]
Vardast, Mohammad Reza [2 ,3 ]
机构
[1] Univ Tabriz, Dept Analyt Chem, Fac Chem, Tabriz, Iran
[2] Urmia Univ, Dept Chem, Fac Sci, Orumiyeh, Iran
[3] Islamic Azad Univ, Marand, Iran
关键词
Central composite design; Co(II); Dispersive liquid-liquid microextraction; Fe(III); HPLC; ATOMIC-ABSORPTION-SPECTROMETRY; CLOUD-POINT EXTRACTION; SINGLE-DROP MICROEXTRACTION; TERNARY SOLVENT SYSTEM; ORGANOPHOSPHORUS PESTICIDES; EXPERIMENTAL-DESIGN; ARRAY DETECTION; NATURAL-WATERS; TRACE CADMIUM; COPPER II;
D O I
10.1002/jssc.200900460
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In this study, dispersive liquid-liquid microextraction method was used for the preconcentration and simultaneous determination of Co(II) and Fe(III) in water samples as their oxinate chelates. in dispersive liquid-liquid microextraction process, methanol and chloroform were used as disperser and extracting solvents, respectively, and the ligand 8-hydroxy quinoline was used as a chelating agent for the extraction of Co(II) and Fe(III). HPLC was applied for the quantitation of the analytes after preconcentration. An experimental design, central composite design, coupled with response surface methodology was used for the optimization of the involved experimental parameters. In addition, the effect of various experimental parameters in the extraction was investigated using one variable at a time method. The calibration graphs were linear in the range of 20-4000 mu g/L with the LODs of 3 mu g/L for both analytes. The RSDs for six replicate measurements of 500 mu g/L of Co2+ and Fe3+ were 3.3 and 4.1%, respectively.
引用
收藏
页码:4200 / 4212
页数:13
相关论文
共 36 条
[1]  
[Anonymous], 1998, STAND METH EX WAT WA, V20th
[2]   On-line liquid-liquid extraction system using a new phase separator for flame atomic absorption spectrometric determination of ultra-trace cadmium in natural waters [J].
Anthemidis, AN ;
Zachariadis, GA ;
Farastelis, CG ;
Stratis, JA .
TALANTA, 2004, 62 (03) :437-443
[3]   Experimental design .2. Optimization [J].
Araujo, PW ;
Brereton, RG .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 1996, 15 (02) :63-70
[4]   Dispersive liquid-liquid microextraction combined with gas chromatography-flame photometric detection - Very simple, rapid and sensitive method for the determination of organophosphorus pesticides in water [J].
Berijani, Sana ;
Assadi, Yaghoub ;
Anbia, Mansoor ;
Milani Hosseini, Mohammad-Reza ;
Aghaee, Elham .
JOURNAL OF CHROMATOGRAPHY A, 2006, 1123 (01) :1-9
[5]   Determination of barium, chromium, cadmium, manganese, lead and zinc in atmospheric particulate matter by inductively coupled plasma atomic emission spectrometry (ICP-AES) [J].
Boevski, I ;
Daskalova, N ;
Havezov, I .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2000, 55 (11) :1643-1657
[6]   Cloud-point extraction for the determination of Cd, Pb and Pd in blood by electrothermal atomic absorption spectrometry, using Ir or Ru as permanent modifiers [J].
Borges, DLG ;
da Veiga, MAMS ;
Frescura, VLA ;
Welz, B ;
Curtius, AJ .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2003, 18 (05) :501-507
[7]  
BULACOV J, 2006, SURF COAT TECH, V201, P255
[8]   Determination of arsenic by electrothermal atomic absorption spectrometry using headspace liquid phase microextraction after in situ hydride generation [J].
Chamsaz, M ;
Arbab-Zavar, MH ;
Nazari, S .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2003, 18 (10) :1279-1282
[9]   Optimization of dispersive liquid-liquid microextraction of copper (II) by atomic absorption spectrometry as its oxinate chelate:: Application to determination of copper in different water samples [J].
Farajzadeh, Mir Ali ;
Bahram, Morteza ;
Mehr, Behzad Ghorbani ;
Jonsson, Jan Ake .
TALANTA, 2008, 75 (03) :832-840
[10]   Dispersive liquid-liquid microextraction followed by high-performance liquid chromatography-diode array detection as an efficient and sensitive technique for determination of antioxidants [J].
Farajzadeh, Mir Ali ;
Bahram, Morteza ;
Jonsson, Jan Ake .
ANALYTICA CHIMICA ACTA, 2007, 591 (01) :69-79