Acute cerebral infarction: Effect of JPEG compression on detection at CT

被引:20
作者
Ohgiya, Y
Gokan, T
Nobusawa, H
Hirose, M
Seino, N
Fujisawa, H
Baba, M
Nagai, K
Tanno, K
Takeyama, N
Munechika, H
机构
[1] Showa Univ, Sch Med, Dept Radiol, Shinagawa Ku, Tokyo 1420064, Japan
[2] Showa Univ, No Yokohama Hosp, Dept Radiol, Tokyo, Japan
关键词
brain; CT; computed tomography (CT); image processing; data compression; images; interpretation;
D O I
10.1148/radiol.2271020067
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: To evaluate the effect of Joint Photographic Experts Group (JPEG) compression ratios of 10:1 and 20:1 on detection of acute cerebral infarction at computed tomography (CT). MATERIALS AND METHODS: CT images obtained in 25 patients with acute cerebral infarction and 25 patients with no lesions were compressed by means of a JPEG algorithm at ratios of 10:1 and 20:1. Normal and abnormal sections (on original and compressed images) were reviewed by using a color soft-copy computed monochrome cathode ray tube monitor. Five observers rated the presence or i absence of a lesion with a 50-point scale (0, definitely absent; 25, equivocal; and 50, definitely present). Diagnostic accuracy was evaluated with receiver operating characteristic (ROC) curve analysis. Significant difference was defined as a P value less than .05 for the area tested with a two-tailed paired Student t test. RESULTS: At ROC analysis, no statistically significant difference was detected for all cases considered together (A(z) [area under the ROC curve] = 0.887 +/- 0.038 [mean +/- SD] on noncompressed images, A(z) = 0.897 +/- 0.038 on 10:1 compressed images, and A(z) = 0.842 +/- 0.073 on 20:1 compressed images; P > .05). CONCLUSION: JPEG compression at ratios of 10:1 and 20:1 was tolerated in the detection of acute cerebral infarction at CT. (C) RSNA, 2003.
引用
收藏
页码:124 / 127
页数:4
相关论文
共 15 条
  • [1] Chameroy V, 1990, Int J Card Imaging, V5, P261, DOI 10.1007/BF01797843
  • [2] THORACIC CT IMAGES - EFFECT OF LOSSY IMAGE COMPRESSION ON DIAGNOSTIC-ACCURACY
    COSMAN, PC
    DAVIDSON, HC
    BERGIN, CJ
    TSENG, CW
    MOSES, LE
    RISKIN, EA
    OLSHEN, RA
    GRAY, RM
    [J]. RADIOLOGY, 1994, 190 (02) : 517 - 524
  • [3] Wavelet compression of medical images
    Erickson, BJ
    Manduca, A
    Palisson, P
    Persons, KR
    Earnest, F
    Savcenko, V
    Hangiandreou, NJ
    [J]. RADIOLOGY, 1998, 206 (03) : 599 - 607
  • [4] Focal hepatic lesions: Effect of three-dimensional wavelet compression on detection at CT
    Goldberg, MA
    Gazelle, GS
    Boland, GW
    Hahn, PF
    MayoSmith, WW
    Pivovarov, M
    Halpern, EF
    Wittenberg, J
    [J]. RADIOLOGY, 1997, 202 (01) : 159 - 165
  • [5] GORLDBERG MA, 1994, AM J ROENTGENOL, V163, P463
  • [6] Randomised double-blind placebo-controlled trial of thrombolytic therapy with intravenous alteplase in acute ischaemic stroke (ECASS II)
    Hacke, W
    Kaste, M
    Fieschi, C
    von Kummer, R
    Davalos, A
    Meier, D
    Larrue, V
    Bluhmki, E
    Davis, S
    Donnan, G
    Schneider, D
    Diez-Tejedor, E
    Trouillas, P
    [J]. LANCET, 1998, 352 (9136) : 1245 - 1251
  • [7] Karson T H, 1995, J Am Soc Echocardiogr, V8, P306, DOI 10.1016/S0894-7317(05)80041-0
  • [8] DATA-COMPRESSION - EFFECT ON DIAGNOSTIC-ACCURACY IN DIGITAL CHEST RADIOGRAPHY
    MACMAHON, H
    DOI, K
    SANADA, S
    MONTNER, SM
    GIGER, ML
    METZ, CE
    NAKAMORI, N
    YIN, FF
    XU, XW
    YONEKAWA, H
    TAKEUCHI, H
    [J]. RADIOLOGY, 1991, 178 (01) : 175 - 179
  • [9] Wavelet transform-based image compression for transmission of MR data
    Maldjian, JA
    Liu, WC
    Hirschorn, D
    Murthy, R
    Semanczuk, W
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1997, 169 (01) : 23 - 26