APPLICATION OF GLASSY CARBON ELECTRODE MODIFIED WITH NAFION/MWCNTS FOR SENSITIVE VOLTAMMETRIC DETERMINATION OF THYMOL

被引:0
|
作者
Piech, Robert [1 ]
Paczosa-Bator, Beata [1 ]
机构
[1] AGH Univ Sci & Technol, Fac Mat Sci & Ceram, Al Mickiewicza 30, PL-30059 Krakow, Poland
来源
ACTA POLONIAE PHARMACEUTICA | 2015年 / 72卷 / 06期
关键词
thymol; MWCNTs; Nafion; voltammetry; MICROEXTRACTION; DERIVATIVES; CARVACROL; PHENOL; HONEY; OILS;
D O I
暂无
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
The glassy carbon electrode modified with Nafion and multi-walled carbon nanotubes (Nafion/MWCNTs), applied for the determination of thymol using differential pulse voltammetry in phosphoric acid and methanol is presented. The calibration graph obtained for thymol is linear from 0.5 mu M (75 mu g/L) to 5 mu M (750 mu g/L) for a preconcentration time of 15 s, with correlation coefficient of 0.998. For a GC-Nafion/MWCNTs electrode the detection limit for a preconcentration time of 30 s is as low as 7.5 mu g/L. The repeatability of the method at a concentration level of the analyte as low as 75 mu g/L. expressed as RSD is 3.9% (n = 5). The proposed method was successfully applied and validated by studying the recovery of thymol from urine, dental mouthwash and liquid anti-ace.
引用
收藏
页码:1081 / 1088
页数:8
相关论文
共 50 条
  • [31] Nimesulide Determination on Carbon Black-Nafion Modified Glassy Carbon Electrode by Means of Adsorptive Stripping Voltammetry
    Marcelina Łysoń
    Anna Górska
    Beata Paczosa-Bator
    Robert Piech
    Electrocatalysis, 2021, 12 : 641 - 649
  • [32] High Performance of MWCNTs - Chitosan Modified Glassy Carbon Electrode for Voltammetric Trace Analysis of Cd(II)
    Solis, J. Calvillo
    Galicia, M.
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2020, 15 (07): : 6815 - 6828
  • [33] Voltammetric sensitive determination of metronidazole at poly(p-aminobenzene sulfonic acid)-modified glassy carbon electrode
    Gulsen Saglikoglu
    Selehattin Yilmaz
    Russian Journal of Electrochemistry, 2015, 51 : 862 - 866
  • [34] Nimesulide Determination on Carbon Black-Nafion Modified Glassy Carbon Electrode by Means of Adsorptive Stripping Voltammetry
    Lyson, Marcelina
    Gorska, Anna
    Paczosa-Bator, Beata
    Piech, Robert
    ELECTROCATALYSIS, 2021, 12 (06) : 641 - 649
  • [35] A Sensitive Chlorpromazine Voltammetric Sensor Based on Graphene Oxide Modified Glassy Carbon Electrode
    Tajik, Somayeh
    Beitollahi, Hadi
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY RESEARCH, 2019, 6 (01): : 171 - 182
  • [36] Highly Sensitive Levodopa Determination by Means of Adsorptive Stripping Voltammetry on Ruthenium Dioxide-Carbon Black-Nafion Modified Glassy Carbon Electrode
    Gorska, Anna
    Paczosa-Bator, Beata
    Piech, Robert
    SENSORS, 2021, 21 (01) : 1 - 12
  • [37] Voltammetric determination of ethyl acetate in ethanol fuel using a Fe3+/Nafion®-coated glassy carbon electrode
    Caetano, Lahys G.
    Takeuchi, Regina M.
    Santos, Andre L.
    de Oliveira, Marcelo F.
    Stradiotto, Nelson R.
    FUEL, 2013, 106 : 837 - 842
  • [38] Voltammetric Determination of Nifedipine on Carbon Nanotubes-Modified Glassy Carbon Electrode: A new Application to Dissolution Test Studies
    Jara-Ulloa, P.
    Salgado-Figueroa, P.
    Yanez, C.
    Nunez-Vergara, L. J.
    Squella, J. A.
    ELECTROANALYSIS, 2012, 24 (08) : 1751 - 1757
  • [39] Nafion/multi-wall carbon nanotubes composite film coated glassy carbon electrode for sensitive determination of caffeine
    Yang, Suling
    Yang, Ran
    Li, Gang
    Qu, Lingbo
    Li, Jianjun
    Yu, Lanlan
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2010, 639 (1-2) : 77 - 82
  • [40] Electrochemical determination of naltrexone on the surface of glassy carbon electrode modified with Nafion-doped carbon nanoparticles: Application to determinations in pharmaceutical and clinical preparations
    Ghorbani-Bidkorbeh, Fatemeh
    Shahrokhian, Saeed
    Mohammadi, Ali
    Dinarvand, Rassoul
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2010, 638 (02) : 212 - 217