APPLICATION OF GLASSY CARBON ELECTRODE MODIFIED WITH NAFION/MWCNTS FOR SENSITIVE VOLTAMMETRIC DETERMINATION OF THYMOL

被引:0
|
作者
Piech, Robert [1 ]
Paczosa-Bator, Beata [1 ]
机构
[1] AGH Univ Sci & Technol, Fac Mat Sci & Ceram, Al Mickiewicza 30, PL-30059 Krakow, Poland
来源
ACTA POLONIAE PHARMACEUTICA | 2015年 / 72卷 / 06期
关键词
thymol; MWCNTs; Nafion; voltammetry; MICROEXTRACTION; DERIVATIVES; CARVACROL; PHENOL; HONEY; OILS;
D O I
暂无
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
The glassy carbon electrode modified with Nafion and multi-walled carbon nanotubes (Nafion/MWCNTs), applied for the determination of thymol using differential pulse voltammetry in phosphoric acid and methanol is presented. The calibration graph obtained for thymol is linear from 0.5 mu M (75 mu g/L) to 5 mu M (750 mu g/L) for a preconcentration time of 15 s, with correlation coefficient of 0.998. For a GC-Nafion/MWCNTs electrode the detection limit for a preconcentration time of 30 s is as low as 7.5 mu g/L. The repeatability of the method at a concentration level of the analyte as low as 75 mu g/L. expressed as RSD is 3.9% (n = 5). The proposed method was successfully applied and validated by studying the recovery of thymol from urine, dental mouthwash and liquid anti-ace.
引用
收藏
页码:1081 / 1088
页数:8
相关论文
共 50 条
  • [21] A new sensitive voltammetric determination of thymol based on MnY nanozeolite modified carbon paste electrode using response surface methodology
    Aghamohseni, Behnaz
    Hassaninejad-Darzi, Seyed Karim
    Asadollahi-Baboli, Mohammad
    MICROCHEMICAL JOURNAL, 2019, 145 : 819 - 832
  • [22] Simultaneous voltammetric determination of paracetamol and domperidone based on a graphene/platinum nanoparticles/nafion composite modified glassy carbon electrode
    Kalambate, Pramod K.
    Sanghavi, Bankim J.
    Karna, Shashi P.
    Srivastava, Ashwini K.
    SENSORS AND ACTUATORS B-CHEMICAL, 2015, 213 : 285 - 294
  • [23] Voltammetric Determinations of Thymol on an Electrode Modified by Coimmobilized Carboxylated Multiwalled Carbon Nanotubes and Surfactants
    Ziyatdinova, G. K.
    Romashkina, S. A.
    Ziganshina, E. R.
    Budnikov, H. C.
    JOURNAL OF ANALYTICAL CHEMISTRY, 2018, 73 (01) : 63 - 70
  • [24] Voltammetric Sensing of Bilirubin Based on Nafion/Electrochemically Reduced Graphene Oxide Composite Modified Glassy Carbon Electrode
    Avan, Asiye Aslihan
    Aydar, Sevda
    Filik, Hayati
    CURRENT ANALYTICAL CHEMISTRY, 2015, 11 (02) : 96 - 103
  • [25] Determination of caffeine at a Nafion-covered glassy carbon electrode
    Brunetti, Barbara
    Desimoni, Elio
    Casati, Paolo
    ELECTROANALYSIS, 2007, 19 (2-3) : 385 - 388
  • [26] Voltammetric determination of resorcinol on the surface of a glassy carbon electrode modified with multi-walled carbon nanotube
    Ghoreishi, Sayed Mehdi
    Behpour, Mohsem
    Hajisadeghian, Elahe
    Golestaneh, Mahshid
    ARABIAN JOURNAL OF CHEMISTRY, 2016, 9 : S1563 - S1568
  • [27] Sensitive Voltammetric Determination of Paracetamol on Poly(4-Aminobenzene Sulfonic Acid) Modified Glassy Carbon Electrode
    Yilmaz, Selehattin
    Bas, Zeynep
    Sadikoglu, Murat
    Yagmur, Sultan
    Saglikoglu, Gulsen
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2016, 11 (07): : 6244 - 6255
  • [28] Voltammetric sensitive determination of metronidazole at poly(p-aminobenzene sulfonic acid)-modified glassy carbon electrode
    Saglikoglu, Gulsen
    Yilmaz, Selehattin
    RUSSIAN JOURNAL OF ELECTROCHEMISTRY, 2015, 51 (09) : 862 - 866
  • [29] Graphene nanocomposite modified glassy carbon electrode for voltammetric determination of the antipsychotic quetiapine
    Biljana Nigović
    Ana Mornar
    Miranda Sertić
    Microchimica Acta, 2016, 183 : 1459 - 1467
  • [30] Graphene nanocomposite modified glassy carbon electrode for voltammetric determination of the antipsychotic quetiapine
    Nigovic, Biljana
    Mornar, Ana
    Sertic, Miranda
    MICROCHIMICA ACTA, 2016, 183 (04) : 1459 - 1467