APPLICATION OF GLASSY CARBON ELECTRODE MODIFIED WITH NAFION/MWCNTS FOR SENSITIVE VOLTAMMETRIC DETERMINATION OF THYMOL

被引:0
|
作者
Piech, Robert [1 ]
Paczosa-Bator, Beata [1 ]
机构
[1] AGH Univ Sci & Technol, Fac Mat Sci & Ceram, Al Mickiewicza 30, PL-30059 Krakow, Poland
来源
ACTA POLONIAE PHARMACEUTICA | 2015年 / 72卷 / 06期
关键词
thymol; MWCNTs; Nafion; voltammetry; MICROEXTRACTION; DERIVATIVES; CARVACROL; PHENOL; HONEY; OILS;
D O I
暂无
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
The glassy carbon electrode modified with Nafion and multi-walled carbon nanotubes (Nafion/MWCNTs), applied for the determination of thymol using differential pulse voltammetry in phosphoric acid and methanol is presented. The calibration graph obtained for thymol is linear from 0.5 mu M (75 mu g/L) to 5 mu M (750 mu g/L) for a preconcentration time of 15 s, with correlation coefficient of 0.998. For a GC-Nafion/MWCNTs electrode the detection limit for a preconcentration time of 30 s is as low as 7.5 mu g/L. The repeatability of the method at a concentration level of the analyte as low as 75 mu g/L. expressed as RSD is 3.9% (n = 5). The proposed method was successfully applied and validated by studying the recovery of thymol from urine, dental mouthwash and liquid anti-ace.
引用
收藏
页码:1081 / 1088
页数:8
相关论文
共 50 条
  • [1] High Sensitive Voltammetric Determination of Paroxetine on Glassy Carbon Electrode Modified with Nafion/MWCNTs
    Piech, Robert
    Rumin, Martyna
    Paczosa-Bator, Beata
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2014, 9 (12): : 7528 - 7539
  • [2] Modified glassy carbon electrode with Nafion/MWNTs as a sensitive voltammetric sensor for the determination of paeonol in pharmaceutical and biological samples
    Yang, Suling
    Qu, Lingbo
    Yang, Ran
    Li, Jianjun
    Yu, Lanlan
    JOURNAL OF APPLIED ELECTROCHEMISTRY, 2010, 40 (07) : 1371 - 1378
  • [3] Modified glassy carbon electrode with Nafion/MWNTs as a sensitive voltammetric sensor for the determination of paeonol in pharmaceutical and biological samples
    Suling Yang
    Lingbo Qu
    Ran Yang
    Jianjun Li
    Lanlan Yu
    Journal of Applied Electrochemistry, 2010, 40 : 1371 - 1378
  • [4] Voltammetric behavior and determination of estrogens at Nafion-modified glassy carbon electrode in the presence of cetyltrimethylammonium bromide
    Hu, SS
    Wu, KB
    Yi, HC
    Cui, DF
    ANALYTICA CHIMICA ACTA, 2002, 464 (02) : 209 - 216
  • [5] Voltammetric sensor for caffeine based on a glassy carbon electrode modified with Nafion and graphene oxide
    Fangyuan Zhao
    Fei Wang
    Weining Zhao
    Jing Zhou
    Yang Liu
    Lina Zou
    Baoxian Ye
    Microchimica Acta, 2011, 174 : 383 - 390
  • [6] TiO2/MWCNT/Nafion-Modified Glassy Carbon Electrode as a Sensitive Voltammetric Sensor for the Determination of Hydrogen Peroxide
    de Oliveira, Rafael Henrique
    Goncalves, Daniel A.
    dos Reis, Diogo Duarte
    SENSORS, 2023, 23 (18)
  • [7] Voltammetric sensor for caffeine based on a glassy carbon electrode modified with Nafion and graphene oxide
    Zhao, Fangyuan
    Wang, Fei
    Zhao, Weining
    Zhou, Jing
    Liu, Yang
    Zou, Lina
    Ye, Baoxian
    MICROCHIMICA ACTA, 2011, 174 (3-4) : 383 - 390
  • [8] Voltammetric determination of theophylline at a Nafion/multi-wall carbon nanotubes composite film-modified glassy carbon electrode
    Suling Yang
    Ran Yang
    Gang Li
    Jianjun Li
    Lingbo Qu
    Journal of Chemical Sciences, 2010, 122 : 919 - 926
  • [9] Voltammetric determination of theophylline at a Nafion/multi-wall carbon nanotubes composite film-modified glassy carbon electrode
    Yang, Suling
    Yang, Ran
    Li, Gang
    Li, Jianjun
    Qu, Lingbo
    JOURNAL OF CHEMICAL SCIENCES, 2010, 122 (06) : 919 - 926
  • [10] Voltammetric determination of L-dopa using a carbon nanotubes-Nafion modified glassy carbon electrode
    Xiang, Cuili
    Zou, Yongjin
    Xie, Jingjing
    Fei, Ximing
    ANALYTICAL LETTERS, 2006, 39 (13) : 2569 - 2579