A novel technique to immobilize DNA on surface of a quartz crystal microbalance by plasma treatment and graft polymerization

被引:19
作者
Chen, Ko-Shao [1 ]
Chen, Su-Chen
Lin, Hong-Ru
Yan, Tsong-Rong
Tseng, Ching-Ching
机构
[1] Tatung Univ, Dept Mat Engn, Taipei 104, Taiwan
[2] Tatung Univ, Dept Bioengn, Taipei 104, Taiwan
[3] Taiwan Text Res Inst, Dept Raw Mat & Yarn Format, Taipei, Taiwan
来源
MATERIALS SCIENCE & ENGINEERING C-BIOMIMETIC AND SUPRAMOLECULAR SYSTEMS | 2007年 / 27卷 / 04期
关键词
plasma; surface modification; QCM;
D O I
10.1016/j.msec.2006.07.004
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
A quartz crystal microbalance (QCM) is well known to provide mass-sensitive devices in nanogram levels, because of the resonance frequency changes upon the adsorption on the electrode. It offers the possibility of monitoring hybridization in real time and with high selectivity. In this study, a biosensor system was developed for the detection of Vibrio parahaemolyticus via its oligonucleotide probe immobilized on the gold electrodes' surface of QCM. However, because the surface of QCM was an inorganic substance, it was difficult to immobilize the oligonucleotide probe. In this study, the plasma surface modification of QCM through deposition of hexamethyldisilazane (HMDSZ) films as an interlayer was investigated. The interlayer provided good adhesion to the substrate and had a uniform structure. The result indicates that plasma deposition was a useful technique to immobilize the oligonucleotide probe on the gold electrodes' surface via glutaraldehyde (GA) coupling. To improve immobilization, post treatments by surface grafting of acrylamide (AAm) and polyethyleneimine (PEI) treatment onto the electrodes were also performed. The result demonstrates that the shift of resonance frequency of QCM was improved via subsequent graft polymerization of AAm and PEI treatment onto the electrodes. The QCM sensor after plasma deposition and surface modification could provide detection sensitivity up to 86 ng/ml and kept at 88% detecting sensitivity after 19 days of storage at 0 degrees C. After washing with 0.1 M NaOH solution and 7 times of repeated use in detecting, the regeneration rate of QCM could be up to 60%. (C) 2006 Elsevier B.V. All rights reserved.
引用
收藏
页码:716 / 724
页数:9
相关论文
共 20 条
  • [1] In-situ measurement of DNA immobilization and hybridization using a 27 MHz quartz crystal microbalance
    Caruso, F
    Furlong, DN
    Niikura, K
    Okahata, Y
    [J]. COLLOIDS AND SURFACES B-BIOINTERFACES, 1998, 10 (04) : 199 - 204
  • [2] Quartz crystal microbalance study of DNA immobilization and hybridization for nucleic acid sensor development
    Caruso, F
    Rodda, E
    Furlong, DF
    Niikura, K
    Okahata, Y
    [J]. ANALYTICAL CHEMISTRY, 1997, 69 (11) : 2043 - 2049
  • [3] Quantitative analysis for solid-phase hybridization reaction and binding reaction of DNA binder to hybrids using a quartz crystal microbalance
    Ito, K
    Hashimoto, K
    Ishimori, Y
    [J]. ANALYTICA CHIMICA ACTA, 1996, 327 (01) : 29 - 35
  • [4] Detection of PCR products in solution using surface plasmon resonance
    Kai, E
    Sawata, S
    Ikebukuro, K
    Iida, T
    Honda, T
    Karube, I
    [J]. ANALYTICAL CHEMISTRY, 1999, 71 (04) : 796 - 800
  • [5] Solid-phase genetic engineering with DNA immobilized on a gold surface
    Kim, JH
    Hong, JA
    Yoon, M
    Yoon, MY
    Jeong, HS
    Hwang, HJ
    [J]. JOURNAL OF BIOTECHNOLOGY, 2002, 96 (03) : 213 - 221
  • [6] Fibre-optic genosensor for specific determination of femtomolar DNA oligomers
    Kleinjung, F
    Bier, FF
    Warsinke, A
    Scheller, FW
    [J]. ANALYTICA CHIMICA ACTA, 1997, 350 (1-2) : 51 - 58
  • [7] Comparison of different protein immobilization methods on quartz crystal microbalance surface in flow injection immunoassay
    Liu, YC
    Wang, CM
    Hsiung, KP
    [J]. ANALYTICAL BIOCHEMISTRY, 2001, 299 (02) : 130 - 135
  • [8] Capacitive monitoring of protein immobilization and antigen-antibody reactions on monomolecular alkylthiol films on gold electrodes
    Mirsky, VM
    Riepl, M
    Wolfbeis, OS
    [J]. BIOSENSORS & BIOELECTRONICS, 1997, 12 (9-10) : 977 - 989
  • [9] Resuscitation of viable but nonculturable cells of Vibrio parahaemolyticus induced at low temperature under starvation
    Mizunoe, Y
    Wai, SN
    Ishikawa, T
    Takade, A
    Yoshida, S
    [J]. FEMS MICROBIOLOGY LETTERS, 2000, 186 (01) : 115 - 120
  • [10] Plasma-polymerized films for biosensors
    Muguruma, H
    Karube, I
    [J]. TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 1999, 18 (01) : 62 - 68