Magnetic resonance imaging versus Doppler guide wire in the assessment of coronary flow reserve in patients with coronary artery disease

被引:14
作者
Bedaux, WLF
Hofman, MBM
de Cock, CC
Stoel, MG
Visser, CA
van Rossum, AC
机构
[1] Vrije Univ Amsterdam Med Ctr, Dept Cardiol, NL-1081 HV Amsterdam, Netherlands
[2] Vrije Univ Amsterdam Med Ctr, Dept Clin Phys & Informat, NL-1081 HV Amsterdam, Netherlands
[3] Interuniv Cardiol Inst Netherlands, Utrecht, Netherlands
[4] ICaRVU, Inst Cardiovasc Res, Amsterdam, Netherlands
关键词
magnetic resonance imaging; coronary artery disease; Doppler ultrasonography; coronary flow reserve;
D O I
10.1097/00019501-200211000-00003
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background Coronary flow velocity reserve (CFVR), defined as the ratio of maximal hyperaemic to baseline flow velocity, has been validated as a marker of physiological significance of a coronary lesion. Clinically, this parameter is measured invasively during X-ray angiography using the Doppler guide wire. With magnetic resonance (MR) imaging it is possible to quantify CFVR non-invasively. Design The purpose of the study was to compare CFVR, acquired with MR imaging and the Doppler guide wire in patients with coronary artery disease. Methods Twenty-two patients suffering from one- or two-vessel coronary artery disease as derived from diagnostic X-ray coronary angiography were included. Coronary flow velocity reserve was measured at baseline and during maximal hyperaemia, obtained by intravenous administration of adenosine using MR phase contrast velocity quantification. Within 2 weeks CFVR was measured invasively with a Doppler guide wire. Results In 26 coronary arteries CFVR was acquired with both techniques. Mean CFVR in the stenosed and healthy reference arteries was 1.5 +/- 0.7 and 2.7 +/- 1.0 (P < 0.01) respectively for MR measurements and 1.9 +/- 0.7 and 3.1 +/- 0.6 (P < 0.01) respectively for Doppler measurements. Bland-Altman analysis revealed a non-significant mean difference between the two techniques of 0.4 +/- 1.2. Conclusion In a selected group of stable patients with coronary artery disease MR flow velocity quantification provides non-invasive data equivalent to the invasive Doppler guide wire data. Variability in both the MR and Doppler ultrasound measurement resulted in a significant scatter of data without systematic difference.
引用
收藏
页码:365 / 372
页数:8
相关论文
共 38 条
[31]   Measurement of fractional flow reserve to assess the functional severity of coronary-artery stenoses [J].
Pijls, NHJ ;
DeBruyne, B ;
Peels, K ;
VanderVoort, PH ;
Bonnier, HJRM ;
Bartunek, J ;
Koolen, JJ .
NEW ENGLAND JOURNAL OF MEDICINE, 1996, 334 (26) :1703-1708
[32]   Coronary flow reserve: Noninvasive measurement in humans with breath-hold velocity-encoded cine MR imaging [J].
Sakuma, H ;
Blake, LM ;
Amidon, TM ;
OSullivan, M ;
Szolar, DH ;
Furber, AP ;
Bernstein, MA ;
Foo, TKF ;
Higgins, CB .
RADIOLOGY, 1996, 198 (03) :745-750
[33]  
Serruys PW, 1997, CIRCULATION, V96, P3369
[34]  
Shibata M, 1999, J MAGN RESON IMAGING, V10, P563, DOI 10.1002/(SICI)1522-2586(199910)10:4<563::AID-JMRI9>3.3.CO
[35]  
2-8
[36]   Coronary flow and flow reserve in canines using MR phase difference and complex difference processing [J].
Wedding, KL ;
Grist, TM ;
Folts, JD ;
Maalej, N ;
Vigen, KK ;
Peters, DC ;
Osman, H ;
Mistretta, CA .
MAGNETIC RESONANCE IN MEDICINE, 1998, 40 (05) :656-665
[37]   DOES VISUAL INTERPRETATION OF THE CORONARY ARTERIOGRAM PREDICT THE PHYSIOLOGIC IMPORTANCE OF A CORONARY STENOSIS [J].
WHITE, CW ;
WRIGHT, CB ;
DOTY, DB ;
HIRATZA, LF ;
EASTHAM, CL ;
HARRISON, DG ;
MARCUS, ML .
NEW ENGLAND JOURNAL OF MEDICINE, 1984, 310 (13) :819-824
[38]   EFFECTS OF ADENOSINE ON HUMAN CORONARY ARTERIAL CIRCULATION [J].
WILSON, RF ;
WYCHE, K ;
CHRISTENSEN, BV ;
ZIMMER, S ;
LAXSON, DD .
CIRCULATION, 1990, 82 (05) :1595-1606