摘要
Background Coronary flow velocity reserve (CFVR), defined as the ratio of maximal hyperaemic to baseline flow velocity, has been validated as a marker of physiological significance of a coronary lesion. Clinically, this parameter is measured invasively during X-ray angiography using the Doppler guide wire. With magnetic resonance (MR) imaging it is possible to quantify CFVR non-invasively. Design The purpose of the study was to compare CFVR, acquired with MR imaging and the Doppler guide wire in patients with coronary artery disease. Methods Twenty-two patients suffering from one- or two-vessel coronary artery disease as derived from diagnostic X-ray coronary angiography were included. Coronary flow velocity reserve was measured at baseline and during maximal hyperaemia, obtained by intravenous administration of adenosine using MR phase contrast velocity quantification. Within 2 weeks CFVR was measured invasively with a Doppler guide wire. Results In 26 coronary arteries CFVR was acquired with both techniques. Mean CFVR in the stenosed and healthy reference arteries was 1.5 +/- 0.7 and 2.7 +/- 1.0 (P < 0.01) respectively for MR measurements and 1.9 +/- 0.7 and 3.1 +/- 0.6 (P < 0.01) respectively for Doppler measurements. Bland-Altman analysis revealed a non-significant mean difference between the two techniques of 0.4 +/- 1.2. Conclusion In a selected group of stable patients with coronary artery disease MR flow velocity quantification provides non-invasive data equivalent to the invasive Doppler guide wire data. Variability in both the MR and Doppler ultrasound measurement resulted in a significant scatter of data without systematic difference.
引用
收藏
页码:365 / 372
页数:8
相关论文
共 38 条
[1]   Accuracy of segmented MR velocity mapping to measure small vessel pulsatile flow in a phantom simulating cardiac motion [J].
Arheden, H ;
Saeed, M ;
Törnqvist, E ;
Lund, G ;
Wendland, MF ;
Higgins, CB ;
Ståhlberg, F .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2001, 13 (05) :722-728
[2]   QUANTITATIVE CORONARY ANGIOGRAPHY IN THE ESTIMATION OF THE FUNCTIONAL-SIGNIFICANCE OF CORONARY STENOSIS - CORRELATIONS WITH DOBUTAMINE-ATROPINE STRESS TEST [J].
BAPTISTA, J ;
ARNESE, M ;
ROELANDT, JRTC ;
FIORETTI, P ;
KEANE, D ;
ESCANED, J ;
BOERSMA, E ;
DIMARIO, C ;
SERRUYS, PW .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1994, 23 (06) :1434-1439
[3]   Velocity-encoded, phase-difference cine MRI measurements of coronary artery flow: Dependence of flow accuracy on the number of cine frames [J].
Clarke, GD ;
Hundley, WG ;
McColl, RW ;
Eckels, R ;
Smith, D ;
Chaney, C ;
Li, HF ;
Peshock, RM .
JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1996, 6 (05) :733-742
[4]   MEASUREMENT OF ABSOLUTE EPICARDIAL CORONARY-ARTERY FLOW AND FLOW RESERVE WITH BREATH-HOLD CINE PHASE-CONTRAST MAGNETIC-RESONANCE-IMAGING [J].
CLARKE, GD ;
ECKELS, R ;
CHANEY, C ;
SMITH, D ;
DITTRICH, J ;
HUNDLEY, WG ;
NESSAIVER, M ;
LI, HF ;
PARKEY, RW ;
PESHOCK, RM .
CIRCULATION, 1995, 91 (10) :2627-2634
[5]   Coronary flow and coronary flow reserve measurements in humans with breath-held magnetic resonance phase contrast velocity mapping [J].
Davis, CP ;
Liu, PF ;
Hauser, M ;
Gohde, SC ;
vonSchulthess, GK ;
Debatin, JF .
MAGNETIC RESONANCE IN MEDICINE, 1997, 37 (04) :537-544
[6]   VALIDATION OF A DOPPLER GUIDE WIRE FOR INTRAVASCULAR MEASUREMENT OF CORONARY-ARTERY FLOW VELOCITY [J].
DOUCETTE, JW ;
CORL, PD ;
PAYNE, HM ;
FLYNN, AE ;
GOTO, M ;
NASSI, M ;
SEGAL, J .
CIRCULATION, 1992, 85 (05) :1899-1911
[7]   FLOW VELOCITY QUANTIFICATION IN HUMAN CORONARY-ARTERIES WITH FAST, BREATH-HOLD MR-ANGIOGRAPHY [J].
EDELMAN, RR ;
MANNING, WJ ;
GERVINO, E ;
LI, W .
JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1993, 3 (05) :699-703
[8]   CORONARY-ARTERIES - BREATH-HOLD MR ANGIOGRAPHY [J].
EDELMAN, RR ;
MANNING, WJ ;
BURSTEIN, D ;
PAULIN, S .
RADIOLOGY, 1991, 181 (03) :641-643
[9]   RELATION BETWEEN GEOMETRIC DIMENSIONS OF CORONARY-ARTERY STENOSES AND MYOCARDIAL PERFUSION RESERVE IN MAN [J].
GOLDSTEIN, RA ;
KIRKEEIDE, RL ;
DEMER, LL ;
MERHIGE, M ;
NISHIKAWA, A ;
SMALLING, RW ;
MULLANI, NA ;
GOULD, KL .
JOURNAL OF CLINICAL INVESTIGATION, 1987, 79 (05) :1473-1478
[10]   PHYSIOLOGIC BASIS FOR ASSESSING CRITICAL CORONARY STENOSIS - INSTANTANEOUS FLOW RESPONSE AND REGIONAL DISTRIBUTION DURING CORONARY HYPEREMIA AS MEASURES OF CORONARY FLOW RESERVE [J].
GOULD, KL ;
LIPSCOMB, K ;
HAMILTON, GW .
AMERICAN JOURNAL OF CARDIOLOGY, 1974, 33 (01) :87-94