Validity and Reliability of Kinematics Measured with PUSH Band vs. Linear Encoder in Bench Press and Push-Ups

被引:18
作者
van den Tillaar, Roland [1 ]
Ball, Nick [2 ]
机构
[1] Nord Univ, Dept Sport Sci & Phys Educ, N-7601 Levanger, Norway
[2] Univ Canberra, Res Inst Sport & Exercise Sci, Fac Hlth, Canberra, ACT 2601, Australia
关键词
peak velocity; mean velocity; resistance training; strength; 1; RM; LOAD-VELOCITY RELATIONSHIP; MOVEMENT VELOCITY; STRENGTH; PERFORMANCE;
D O I
10.3390/sports7090207
中图分类号
G8 [体育];
学科分类号
04 ; 0403 ;
摘要
Background: The aim of this study was to compare the validity and reliability of a PUSH band device with a linear encoder to measure movement velocity with different loads during the push-up and bench press exercises. Methods: Twenty resistance-trained athletes performed push-up and bench press exercises with four different loads: without weight vest, 10-20-30 kg weight vest, bench press: 50-82% of their assumed 1 repetition maximum (1 RM) in steps of 10 kg. A linear encoder (Musclelab) and the PUSH band measured mean and peak velocity during both exercises. Several statistical analyses were used to investigate the validity and reliability of the PUSH band with the linear encoder. Results: The main findings of this study demonstrated only moderate associations between the PUSH band and linear encoder for mean velocity (r = 0.62, 0.70) and peak velocity (r = 0.46, 0.49) for both exercises. Furthermore, a good level of agreement (peak velocity: ICC = 0.60, 0.64; mean velocity: ICC = 0.77, 0.78) was observed between the two measurement devices. However, a significant bias was found with lower velocity values measured with the PUSH band in both exercises. In the push-up, both the linear encoder and PUSH band were deemed very reliable (ICC > 0.98; the coefficient of variation (CV): 5.9-7.3%). Bench press reliability decreased for the PUSH band (ICC < 0.95), and the coefficient of variance increased to (12.8-13.3%) for the velocity measures. Calculated 1 RM with the two devices was the same for the push-up, while in bench press the PUSH band under-estimated the 1 RM by 14 kg compared to the linear encoder. Conclusions: It was concluded that the PUSH band will show decreased reliability from velocity measures in a bench press exercise and underestimate load-velocity based 1 RM predictions. For training, the PUSH band can be used during push-ups, however caution is suggested when using the device for the purposes of feedback in bench press at increasing loads.
引用
收藏
页数:11
相关论文
共 26 条
[1]   VALIDITY AND RELIABILITY OF THE PUSH WEARABLE DEVICE TO MEASURE MOVEMENT VELOCITY DURING THE BACK SQUAT EXERCISE [J].
Balsalobre-Fernandez, Carlos ;
Kuzdub, Matt ;
Poveda-Ortiz, Pedro ;
del Campo-Vecino, Juan .
JOURNAL OF STRENGTH AND CONDITIONING RESEARCH, 2016, 30 (07) :1968-1974
[2]   RELIABILITY AND VALIDITY OF THE LOAD-VELOCITY RELATIONSHIP TO PREDICT THE 1RM BACK SQUAT [J].
Banyard, Harry G. ;
Nosaka, Kazunori ;
Haff, G. Gregory .
JOURNAL OF STRENGTH AND CONDITIONING RESEARCH, 2017, 31 (07) :1897-1904
[3]   PREDICTING MAXIMAL DYNAMIC STRENGTH FROM THE LOAD-VELOCITY RELATIONSHIP IN SQUAT EXERCISE [J].
Bazuelo-Ruiz, Bruno ;
Padial, Paulino ;
Garcia-Ramos, Amador ;
Morales-Artacho, Antonio J. ;
Miranda, Maria T. ;
Feriche, Belen .
JOURNAL OF STRENGTH AND CONDITIONING RESEARCH, 2015, 29 (07) :1999-2005
[4]  
Bosquet L, 2010, J SPORT SCI MED, V9, P459
[5]  
Cohen JW., 1988, STAT POWER ANAL BEHA, DOI 10.4324/9780203771587
[6]   Reliability of Measures Obtained During Single and Repeated Countermovement Jumps [J].
Cormack, Stuart J. ;
Newton, Robert U. ;
McGuigan, Michael R. ;
Doyle, Tim L. A. .
INTERNATIONAL JOURNAL OF SPORTS PHYSIOLOGY AND PERFORMANCE, 2008, 3 (02) :131-144
[7]   Validation of power measurement techniques in dynamic lower body resistance exercises [J].
Cormie, Prue ;
McBride, Jeffrey M. ;
McCaulley, Grant O. .
JOURNAL OF APPLIED BIOMECHANICS, 2007, 23 (02) :103-118
[8]   The adaptations to strength training - Morphological and neurological contributions to increased strength [J].
Folland, Jonathan P. ;
Williams, Alun G. .
SPORTS MEDICINE, 2007, 37 (02) :145-168
[9]   Differences in the Load-Velocity Profile Between 4 Bench-Press Variants [J].
Garcia-Ramos, Amador ;
Luis Pestana-Melero, Francisco ;
Perez-Castilla, Alejandro ;
Javier Rojas, Francisco ;
Haff, Guy Gregory .
INTERNATIONAL JOURNAL OF SPORTS PHYSIOLOGY AND PERFORMANCE, 2018, 13 (03) :326-331
[10]   Movement Velocity as a Measure of Loading Intensity in Resistance Training [J].
Gonzalez-Badillo, J. J. ;
Sanchez-Medina, L. .
INTERNATIONAL JOURNAL OF SPORTS MEDICINE, 2010, 31 (05) :347-352