Inter-platform reproducibility of liver stiffness measured with two different point shear wave elastography techniques and 2-dimensional shear wave elastography using the comb-push technique

被引:8
作者
Ryu, Hwaseong [1 ]
Ahn, Su Joa [2 ]
Yoon, Jeong Hee [3 ]
Lee, Jeong Min [3 ,4 ,5 ]
机构
[1] Pusan Natl Univ, Dept Radiol, Yangsan Hosp, Yangsan, South Korea
[2] Gachon Univ, Dept Radiol, Gil Med Ctr, Incheon, South Korea
[3] Seoul Natl Univ Hosp, Dept Radiol, 101 Daehak Ro, Seoul 03080, South Korea
[4] Seoul Natl Univ, Dept Radiol, Coll Med, Seoul, South Korea
[5] Seoul Natl Univ, Inst Radiat Med, Med Res Ctr, Seoul, South Korea
关键词
Liver fibrosis; Liver stiffness; Ultrasound elastography; Shear wave elastography; RADIATION FORCE IMPULSE; TRANSIENT ELASTOGRAPHY; ULTRASOUND ELASTOGRAPHY; HEPATITIS-C; NONINVASIVE ASSESSMENT; EFSUMB GUIDELINES; MR ELASTOGRAPHY; CLINICAL-USE; FIBROSIS; INTEROBSERVER;
D O I
10.14366/usg.19001
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: The purpose of this study was to compare the technical success rate and reliability of measurements made using three shear wave elastography (SWE) techniques and to assess the inter-platform reproducibility of the resultant liver stiffness measurements. Methods: This prospective study included 54 patients with liver disease. Liver stiffness (LS) measurements were obtained using 2-point SWE techniques (Virtual Touch Quantification and S-Shearwave) and 2-dimensional (2D) SWE, with transient elastography (TE) serving as the reference standard. The technical success rates and measurement reliability of the three techniques were compared. LS values measured using the three SWE techniques and TE were compared using Spearman correlation coefficients and 95% Bland-Altman limits of agreement. Intra-class correlation coefficients (ICC) were used to analyze the inter-platform reproducibility of LS measurements. Results: The three SWE techniques and TE showed similar technical success rates (P=0.682) but demonstrated significant differences in the reliability of LS measurements (P=0.006) and mean LS measurements (P<0.001). Despite strong correlations (r=0.73-0.94) between SWE systems, various degrees of inter-platform reproducibility (ICC, 0.58-0.92) were observed for the three SWE techniques. The best agreement was observed between S-Shearwave and TE (ICC, 0.92), and the worst agreement was observed between 2D-SWE and TE (ICC, 0.58). In the Bland-Altman analysis, a tendency toward lower LS values with the three SWE techniques than with TE in patients with F3 and F4 disease was observed. Conclusion: Significant inter-system variability was observed in LS measurements made using the three SWE techniques. Therefore, LS values measured using different SWE techniques should not be used interchangeably for longitudinal follow-up.
引用
收藏
页码:345 / 354
页数:10
相关论文
共 40 条
[1]   Prospective Validation of Intra- and Interobserver Reproducibility of a New Point Shear Wave Elastographic Technique for Assessing Liver Stiffness in Patients with Chronic Liver Disease [J].
Ahn, Su Joa ;
Lee, Jeong Min ;
Chang, Won ;
Lee, Sang Min ;
Kang, Hyo-Jin ;
Yang, Hyunkyung ;
Yoon, Jeong Hee ;
Park, Sae Jin ;
Han, Joon Koo .
KOREAN JOURNAL OF RADIOLOGY, 2017, 18 (06) :926-935
[2]   Trends in mortality after diagnosis of hepatitis C virus infection: An international comparison and implications for monitoring the population impact of treatment [J].
Aspinall, Esther J. ;
Hutchinson, Sharon J. ;
Janjua, Naveed Z. ;
Grebely, Jason ;
Yu, Amanda ;
Alavi, Maryam ;
Amin, Janaki ;
Goldberg, David J. ;
Innes, Hamish ;
Law, Matthew ;
Walter, Scott R. ;
Krajden, Mel ;
Dore, Gregory J. .
JOURNAL OF HEPATOLOGY, 2015, 62 (02) :269-277
[3]   EFSUMB Guidelines and Recommendations on the Clinical Use of Ultrasound Elastography. Part 1: Basic Principles and Technology [J].
Bamber, J. ;
Cosgrove, D. ;
Dietrich, C. F. ;
Fromageau, J. ;
Bojunga, J. ;
Calliada, F. ;
Cantisani, V. ;
Correas, J. -M. ;
D'Onofrio, M. ;
Drakonaki, E. E. ;
Fink, M. ;
Friedrich-Rust, M. ;
Gilja, O. H. ;
Havre, R. F. ;
Jenssen, C. ;
Klauser, A. S. ;
Ohlinger, R. ;
Saftoiu, A. ;
Schaefer, F. ;
Sporea, I. ;
Piscaglia, F. .
ULTRASCHALL IN DER MEDIZIN, 2013, 34 (02) :169-184
[4]   Elastography Assessment of Liver Fibrosis: Society of Radiologists in Ultrasound Consensus Conference Statement [J].
Barr, Richard G. ;
Ferraioli, Giovanna ;
Palmeri, Mark L. ;
Goodman, Zachary D. ;
Garcia-Tsao, Guadalupe ;
Rubin, Jonathan ;
Garra, Brian ;
Myers, Robert P. ;
Wilson, Stephanie R. ;
Rubens, Deborah ;
Levine, Deborah .
RADIOLOGY, 2015, 276 (03) :845-861
[5]   An algorithm for the grading of activity in chronic hepatitis C [J].
Bedossa, P ;
Poynard, T .
HEPATOLOGY, 1996, 24 (02) :289-293
[6]   Sampling variability of liver fibrosis in chronic hepatitis C [J].
Bedossa, P ;
Dargère, D ;
Paradis, V .
HEPATOLOGY, 2003, 38 (06) :1449-1457
[7]  
BEDOSSA P, 1994, HEPATOLOGY, V20, P15
[8]   Performance of 2D-SWE.GE for predicting different stages of liver fibrosis, using Transient Elastography as the reference method [J].
Bende, Felix ;
IoanSporea ;
Sirli, Roxana ;
Popescu, Alina ;
Mare, Ruxandra ;
Miutescu, Bogdan ;
Lupusoru, Raluca ;
Moga, Tudor ;
Pienar, Corina .
MEDICAL ULTRASONOGRAPHY, 2017, 19 (02) :143-149
[9]   Factors associated with the impossibility to obtain reliable liver stiffness measurements by means of Acoustic Radiation Force Impulse (ARFI) elastography-Analysis of a cohort of 1031 subjects [J].
Bota, Simona ;
Sporea, Ioan ;
Sirli, Roxana ;
Popescu, Alina ;
Danila, Mirela ;
Jurchis, Ana ;
Gradinaru-Tascau, Oana .
EUROPEAN JOURNAL OF RADIOLOGY, 2014, 83 (02) :268-272
[10]   Non-invasive assessment of liver fibrosis with impulse elastography: Comparison of Supersonic Shear Imaging with ARFI and FibroScan [J].
Cassinotto, Christophe ;
Lapuyade, Bruno ;
Mouries, Amaury ;
Hiriart, Jean-Baptiste ;
Vergniol, Julien ;
Gaye, Delphine ;
Castain, Claire ;
Le Bail, Brigitte ;
Chermak, Faiza ;
Foucher, Juliette ;
Laurent, Francois ;
Montaudon, Michel ;
De Ledinghen, Victor .
JOURNAL OF HEPATOLOGY, 2014, 61 (03) :550-557