Fluoroscopic analysis of knee arthroplasty kinematics during deep flexion kneeling

被引:93
作者
Kanekasu, K
Banks, SA
Honjo, S
Nakata, O
Kato, H
机构
[1] Univ Florida, Gainesville, FL 32611 USA
[2] Saiseikai Takaoka Hosp, Rheumatoid Arthrit Ctr, Takaoka, Toyama, Japan
[3] Biomot Fdn, W Palm Beach, FL USA
关键词
knee arthroplasty; kinematics; fluoroscopy; deep flexion; implant design;
D O I
10.1016/j.arth.2004.03.012
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Achieving deep knee flexion >145degrees is a goal of many patients receiving knee arthroplasty in Asia and the Middle East, yet it is unknown whether knees with implants move similar to the natural knee in these postures. We studied 18 of 36 consecutively operated knees that were able to flex >145degrees using fluoroscopic analysis during kneeling to maximum flexion. An average of 9degrees tibial internal rotation was observed in deep flexion. Posterior condylar translations were observed from 80degrees to 120degrees flexion, and the condyles translated forward in flexion beyond 120degrees. Separation of the condyles from the tibial surface was observed in 9 knees at flexion >130degrees. Very deep flexion can be achieved and is well accommodated using contemporary posterior-stabilized knee arthroplasty, but the kinematics differ from the intact natural knee.
引用
收藏
页码:998 / 1003
页数:6
相关论文
共 17 条
[1]   Knee motions during maximum flexion in fixed and mobile-bearing arthroplasties [J].
Banks, S ;
Bellemans, J ;
Nozaki, H ;
Whiteside, LA ;
Harman, M ;
Hodge, WA .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2003, (410) :131-138
[2]  
Banks S A, 1997, Am J Knee Surg, V10, P261
[3]   In vivo kinematics of cruciate-retaining and -substituting knee arthroplasties [J].
Banks, SA ;
Markovich, GD ;
Hodge, WA .
JOURNAL OF ARTHROPLASTY, 1997, 12 (03) :297-304
[4]   Accurate measurement of three-dimensional knee replacement kinematics using single-plane fluoroscopy [J].
Banks, SA ;
Hodge, WA .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1996, 43 (06) :638-649
[5]   Mechanism of anterior impingement damage in total knee arthroplasty [J].
Banks, SA ;
Harman, MK ;
Hodge, WA .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2002, 84A :37-42
[6]  
BANKS SA, 2003, J BONE JOINT SURG S4, V85
[7]   Fluoroscopic analysis of the kinematics of deep flexion in total knee arthroplasty - Influence of posterior condylar offset [J].
Bellemans, J ;
Banks, S ;
Victor, J ;
Vandenneucker, H ;
Moemans, A .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2002, 84B :50-53
[8]   In vivo determination of posterior femoral rollback for subjects having a NexGen posterior cruciate-retaining total knee arthroplasty [J].
Bertin, KC ;
Komistek, RD ;
Dennis, DA ;
Hoff, WA ;
Anderson, DT ;
Langer, T .
JOURNAL OF ARTHROPLASTY, 2002, 17 (08) :1040-1048
[9]   Range of motion after total knee arthroplasty - The effect of implant design and weight-bearing conditions [J].
Dennis, DA ;
Komistek, RD ;
Stiehl, JB ;
Walker, SA ;
Dennis, KN .
JOURNAL OF ARTHROPLASTY, 1998, 13 (07) :748-752
[10]   Tibiofemoral movement 2: the loaded and unloaded living knee studied by MRI [J].
Hill, PF ;
Vedi, V ;
Williams, A ;
Iwaki, H ;
Pinskerova, V ;
Freeman, MAR .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2000, 82B (08) :1196-1198