Penetration depth into dental casting alloys by Nd:YAG laser

被引:52
作者
Baba, N [1 ]
Watanabe, I
机构
[1] Nagasaki Univ, Grad Sch Biomed Sci, Dept Dev & Reconstruct Med, Div Fixed Prosthodont & Oral Rehabil, Nagasaki, Japan
[2] Texas Christian Univ, Syst Hlth Sci Ctr, Baylor Coll Dent, Dept Biomat Sci, Dallas, TX 75246 USA
关键词
laser welding; penetration depth; alloy;
D O I
10.1002/jbm.b.30117
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
This study investigated the effect of laser-beam welding conditions [voltage (V) and spot diameter (mm)] on the penetration depth into dental casting alloys. Castings (3.0 mm x 8.0 mm x 50 mm) were prepared from the metals used in this study: commercially pure titanium (CP Ti), Ti-6Al-4V, Ti-6Al-7Nb, cobalt-chromium alloy (Co-Cr) and Type IV gold alloy. Two cast blocks of each metal were butted against one another at the 8.0 X 50-mm surfaces. They were then welded at their interface under the following conditions: voltage of 160-340 V, spot diameter of 0.4-1.6 mm, and pulse duration of 10 ms. After laser welding, the blocks were separated, and the penetration depth into each alloy was measured. The data were analyzed with the use of ANOVA at the p < 0.05 level of significance. The penetration depths were as follows: CP Ti (0.29-6.45 mm), Ti-6Al-4V (0.32-5.24 mm), Ti-6Al-7Nb (0.34-5.65 mm), Co-Cr (0.24-6.15 mm), and Type IV gold alloy (0.12-5.22 mm). The voltage and spot diameter affected the penetration depth into the metals tested. When the voltage increased and the spot diameter decreased, the penetration depth increased for each metal. Selecting suitable conditions for laser welding to obtain sufficient penetration depth for the optimal thickness of the metal is important when welding prostheses. (C) 2004 Wiley Periodicals, Inc.
引用
收藏
页码:64 / 68
页数:5
相关论文
共 15 条
[11]   Characterization of the keyhole formed during pulsed Nd-YAG laser interaction with a Ti-6Al-4V metallic target [J].
Perret, O ;
Bizouard, M ;
Naudy, P ;
Pascal, G ;
Noré, D ;
Hordé, Y ;
Delaisse, Y .
JOURNAL OF APPLIED PHYSICS, 2001, 90 (01) :27-30
[12]  
TOGAYA T, 1999, QUINT DENT TECH, V24, P740
[13]   Effect of pressure difference on the quality of titanium casting [J].
Watanabe, I ;
Watkins, JH ;
Nakajima, H ;
Atsuta, M ;
Okabe, T .
JOURNAL OF DENTAL RESEARCH, 1997, 76 (03) :773-779
[14]   Application of cast magnetic attachments to sectional complete dentures for a patient with microstomia: A clinical report [J].
Watanabe, I ;
Tanaka, Y ;
Ohkubo, C ;
Miller, AW .
JOURNAL OF PROSTHETIC DENTISTRY, 2002, 88 (06) :573-577
[15]   Effects of heat treatments on mechanical strength of laser-welded equi-atomic AuCu-6at%Ga alloy [J].
Watanabe, I ;
Liu, J ;
Atsuta, M .
JOURNAL OF DENTAL RESEARCH, 2001, 80 (09) :1813-1817