摘要
LOVETT scale is a parameter that commonly used by the doctor or therapist to determine the muscle strength of the patient's hands, especially post-stroke patients. By creating the system that combine desktop application with MYO armband, we can measure the muscle strength or the movement of patient's forearm including hands. MYO armband from thalmic lab can read the activities of human's hand muscles by placing it on forearm, as some requirement of LOVETT scalling process is muscles strength. The Myo armband has 8 EMG sensors, gyroscope, accelerometer and bluetooth connection for data transfer. we uses armband's data to control a virtual arm which was built in Unity 3D. this virtual arm can move based on MYO armband's sensors. As the arm moves the doctor can monitor the patient's activities from afar.
引用
收藏
页码:66 / 70
页数:5
相关论文
共 12 条
  • [1] Burger Birgitta., 2013, Sound and Music Computing Conference, P172
  • [2] Cadoz Claude., 2000, Trends in Gestural Control of Music
  • [3] Understanding Gesture Expressivity through Muscle Sensing
    Caramiaux, Baptiste
    Donnarumma, Marco
    Tanaka, Atau
    [J]. ACM TRANSACTIONS ON COMPUTER-HUMAN INTERACTION, 2015, 21 (06)
  • [4] Dipietro L, 2003, J REHABIL RES DEV, V40, P179
  • [5] FLORENCE JM, 1992, PHYS THER, V72, P115, DOI 10.1093/ptj/72.2.115
  • [6] Development and evaluation of a low-cost sensor glove for assessment of human finger movements in neurophysiological settings
    Gentner, Reinhard
    Classen, Joseph
    [J]. JOURNAL OF NEUROSCIENCE METHODS, 2009, 178 (01) : 138 - 147
  • [7] Development of finger-motion capturing device based on optical linear encoder
    Li, Kang
    Chen, I-Ming
    Yeo, Song Huat
    Lim, Chee Kian
    [J]. JOURNAL OF REHABILITATION RESEARCH AND DEVELOPMENT, 2011, 48 (01) : 69 - 82
  • [8] Orengo G., 2012, 3 INT C SENS DEV TEC, P21
  • [9] A novel array of flex sensors for a goniometric glove
    Saggio, Giovanni
    [J]. SENSORS AND ACTUATORS A-PHYSICAL, 2014, 205 : 119 - 125
  • [10] A low cost instrumented glove for extended monitoring and functional hand assessment
    Simone, Lisa K.
    Sundarrajan, Nappinnai
    Luo, Xun
    Jia, Yicheng
    Kamper, Derek G.
    [J]. JOURNAL OF NEUROSCIENCE METHODS, 2007, 160 (02) : 335 - 348