Comparison of fast spin-echo and conventional spin-echo magnetic resonance spinal imaging techniques in four normal dogs

被引:4
|
作者
Miyabayashi, T
Smith, M
Tsuruno, Y
机构
[1] Univ Florida, Coll Vet Med, Dept Small Anim Clin Sci, Gainesville, FL 32610 USA
[2] Childrens Hosp, Columbus, OH 43205 USA
关键词
MRI; dogs; spinal cord;
D O I
10.1111/j.1740-8261.2000.tb02078.x
中图分类号
S85 [动物医学(兽医学)];
学科分类号
0906 ;
摘要
Various magnetic resonance (MR) imaging techniques have been used to assess lumbar spinal abnormalities in people, Four, young adult, clinically normal dogs were used to compare Images of the spinal cord acquired using conventional spin-echo and rapid acquisition relaxation-enhanced (RARE), commonly called fast spin-echo (FSE), magnetic resonance imaging techniques. Lateral myelograms were made as an anatomic control, The T2-weighted FSE technique was characterized by better image quality than the T2-weighted conventional spin-echo technique. The short acquisition time with the FSE technique allowed increases in the matrix size and number of excitations, thus improving resolution and signal-to-noise ratio. In canine lumbar spinal MR imaging, use of a FSE technique is recommended to reduce the overall time for imaging and to improve image quality.
引用
收藏
页码:308 / 312
页数:5
相关论文
共 50 条
  • [1] Comparison of conventional spin-echo and fast spin-echo magnetic resonance imaging in the canine brain
    Sage, JE
    Samii, VF
    Abramson, CJ
    Green, EM
    Smith, M
    Dingus, C
    VETERINARY RADIOLOGY & ULTRASOUND, 2006, 47 (03) : 249 - 253
  • [2] Meniscal tears: comparison of the conventional spin-echo and fast spin-echo techniques through image processing
    Nogueira, Ibevan A.
    Frere, Annie F.
    Silva, Alessandro P.
    de Oliveira, Heverton C.
    BIOMEDICAL ENGINEERING ONLINE, 2014, 13
  • [3] MRI of the intracerebral lesions at 0.5 tesla: Comparison of fast spin-echo and conventional spin-echo sequences
    Incesu, L
    Gunes, M
    Akan, H
    Selcuk, MB
    COMPUTERIZED MEDICAL IMAGING AND GRAPHICS, 1996, 20 (02) : 105 - 113
  • [4] MRI After Arthroplasty: Comparison of MAVRIC and Conventional Fast Spin-Echo Techniques
    Hayter, Catherine L.
    Koff, Matthew F.
    Shah, Parina
    Koch, Kevin M.
    Miller, Theodore T.
    Potter, Hollis G.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2011, 197 (03) : W405 - W411
  • [5] Isotropic diffusion weighting in radial fast spin-echo magnetic resonance imaging
    Sarlls, JE
    Newbould, RD
    Altbach, MI
    Gmitro, AF
    Seeger, J
    Trouard, TP
    MAGNETIC RESONANCE IN MEDICINE, 2005, 53 (06) : 1347 - 1354
  • [6] Fast spin-echo for multiple mouse magnetic resonance phenotyping
    Nieman, BJ
    Bock, NA
    Bishop, J
    Sled, JG
    Chen, XJ
    Henkelman, RM
    MAGNETIC RESONANCE IN MEDICINE, 2005, 54 (03) : 532 - 537
  • [7] Isotropic three-dimensional fast spin-echo Cube magnetic resonance dacryocystography: comparison with the three-dimensional fast-recovery fast spin-echo technique
    Zhang, Jing
    Chen, Lang
    Wang, Qiu-Xia
    Liu, Rong
    Zhu, Wen-Zhen
    Luo, Xin
    Peng, Li
    Xiong, Wei
    NEURORADIOLOGY, 2015, 57 (04) : 357 - 365
  • [8] MRI of the knee: value of short echo time fast spin-echo using high performance gradients versus conventional spin-echo imaging for the detection of meniscal tears
    Kowalchuk, RM
    Kneeland, JB
    Dalinka, MK
    Siegelman, ES
    Dockery, WD
    SKELETAL RADIOLOGY, 2000, 29 (09) : 520 - 524
  • [9] Magnetic resonance ultrashort echo time spin-echo imaging of the deepest layers of articular cartilage
    Gao Song
    Du Jiang
    Wang Fei
    Bao ShangLian
    SCIENCE CHINA-LIFE SCIENCES, 2013, 56 (07) : 672 - 674
  • [10] Comparison of fat-saturation fast spin echo versus conventional spin-echo MRI in the detection of rotator cuff pathology
    Needell, SD
    Zlatkin, MB
    JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1997, 7 (04): : 674 - 677