The effect of the aftercooler on the regenerator temperature non-uniformity in a high-capacity pulse tube cryocooler

被引:8
作者
Wei, Tao [1 ]
Tao, Xijun [1 ]
Lin, Jincheng [1 ]
Zhi, Xiaoqin [1 ]
Wang, Kai [1 ]
Qiu, Limin [1 ]
机构
[1] Zhejiang Univ, Inst Refrigerat & Cryogen, 38 Zheda Rd, Hangzhou 310027, Zhejiang, Peoples R China
关键词
Pulse tube cryocooler; Regenerator; Temperature non-uniformity; Aftercooler;
D O I
10.1016/j.applthermaleng.2022.118245
中图分类号
O414.1 [热力学];
学科分类号
摘要
High-power Stirling-type pulse tube cryocoolers (SPTC) are expected to be an ideal candidate for cooling high temperature superconductivity (HTS) for its advantages of compact structure, low maintenance and long service life. However, the regenerator temperature non-uniformity is still a key problem needs to be solved since it significantly deteriorates the cooling performance. As a main heat exchanger, the insufficient and asymmetric heat exchange in the aftercooler may be one of the factors affecting the temperature inhomogeneity inside the regenerator. However, it has been seldom investigated. In this study, the relationship between the performance of the aftercooler and the temperature non-uniformity of the regenerator was investigated based on a high-power SPTC working at ~ 80 K. With the help of Sage simulation, it is found that the inlet temperature of the regenerator has a large effect on its inside temperature distribution. Even an inapparent temperature inhomogeneity at the inlet of the regenerator will induce a large temperature difference in the middle of the regenerator, due to an obvious DC flow generated in the regenerator. By changing the water inlet and outlet directions of the aftercooler, the temperature non-uniformity of the regenerator will consequently change, which means the uneven heat transfer of aftercooler can be one of the main inducements to the temperature nonuniformity inside the regenerator. Further, methods of using copper wire mesh filling at the hot end of the regenerator, and optimizing heat exchange tubes inside the aftercooler were studied to reduce the temperature non-uniformity.
引用
收藏
页数:11
相关论文
共 15 条
[1]   A single-stage Stirling-type pulse tube cryocooler achieving 1080 W at 77 K with four cold fingers driven by one linear compressor [J].
Dang, Haizheng ;
Li, Jiaqi ;
Zha, Rui ;
Tan, Jun ;
Zhang, Tao ;
Zhao, Bangjian ;
Zhao, Yongjiang ;
Li, Ning ;
Tan, Han ;
Xue, Renjun .
CRYOGENICS, 2020, 106
[2]   High-power Stirling-type pulse tube cryocooler: Observation and reduction of regenerator temperature-inhomogeneities [J].
Dietrich, M. ;
Yang, L. W. ;
Thummes, G. .
CRYOGENICS, 2007, 47 (5-6) :306-314
[3]   Temperature inhomogeneity in high capacity pulse tube cryocoolers [J].
Fang, Kai ;
Qiu, Li-min ;
Jiang, Xiao ;
Gan, Zhi-hua ;
Tong, Ning-xiang .
JOURNAL OF ZHEJIANG UNIVERSITY-SCIENCE A, 2015, 16 (11) :910-921
[4]  
Gedeon D, 2005, CRYOCOOLERS 13, P421
[5]   A high-efficiency coaxial pulse tube cryocooler with 500 W cooling capacity at 80 K [J].
Hu, J. Y. ;
Zhang, L. M. ;
Zhu, J. ;
Chen, S. ;
Luo, E. C. ;
Dai, W. ;
Li, H. B. .
CRYOGENICS, 2014, 62 :7-10
[6]   Optimization of regenerator in high capacity Stirling type pulse tube cryocooler [J].
Imura, J. ;
Iwata, N. ;
Yamamoto, H. ;
Ohashi, Y. ;
Nomachi, H. ;
Okumura, N. ;
Nagaya, S. ;
Tamada, T. ;
Hirano, N. .
PHYSICA C-SUPERCONDUCTIVITY AND ITS APPLICATIONS, 2008, 468 (15-20) :2178-2180
[7]  
Jh Z.A, 2007, CRYOCOOLERS, V14
[8]  
Kirkconnell C.S., 2002, CRYOCOOLERS, V10, P239, DOI 10.1007/0-306-47090-X_28
[9]  
Martin JL, 2002, AIP CONF PROC, V613, P662, DOI 10.1063/1.1472079