Performance Evaluation of Outdoor High Voltage Glass Insulators in High Pollution Industrial Areas Using Simulated Acid Rain Contamination

被引:1
|
作者
Ilomuanya, Chibuike [1 ]
Farokhi, Shahab [1 ]
Nekahi, Azam [1 ]
机构
[1] Glasgow Caledonian Univ, Dept Elect & Elect Engn, Glasgow G4 0BA, Lanark, Scotland
关键词
Insulators; Pollution; Flashover; Standards; Rain; Glass; Surface contamination; insulators; partial discharges; pollution;
D O I
10.1109/ACCESS.2022.3193237
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
A suitable, non-standard method for artificial pollution testing using simulated acid rain pollution in a laboratory was developed in this work. The method is applicable to a wide range of climatic conditions and rain acidities. The established method adopts the solid layer principle in the preparation and application of acid rain of various pollution severities to test insulators. Glass cap and pin insulators were contaminated, assembled into strings of two discs and flashover tests carried out on the strings at different orientation angles. The frequency of flashover occurrence, maximum withstand degree of pollution, effect of pollution severity, and effect of orientation angle were investigated. Test results showed that the orientation angle plays little or no role in the flashover of the insulators under dry conditions. Under wet conditions, the insulators performed better when inclined. Flashover voltage was observed to be inversely proportional to time while the time to flashover was inversely proportional to the pollution severity. The probability of flashover increases with an increase in voltage for a fixed pollution severity or increase in pollution severity for a fixed voltage level. This indicates that the probability of flashover under the test condition is a function of pollution severity and voltage.
引用
收藏
页码:80600 / 80608
页数:9
相关论文
共 50 条
  • [1] Contamination Performance of High Voltage Outdoor Insulators in Harsh Marine Pollution Environment
    Hussain, M. Majid
    Farokhi, S.
    McMeekin, S. G.
    Farzaneh, M.
    2017 IEEE 21ST INTERNATIONAL CONFERENCE ON PULSED POWER (PPC), 2017,
  • [2] Evaluation of Electrical Performance on High Voltage Glass Suspended Insulators
    Alles, J.
    Beroual, A.
    George, J-M.
    Brocard, E.
    2017 IEEE ELECTRICAL INSULATION CONFERENCE (EIC), 2017, : 252 - 255
  • [3] PROTECTIVE COATINGS FOR IMPROVING CONTAMINATION PERFORMANCE OF OUTDOOR HIGH-VOLTAGE CERAMIC INSULATORS
    GORUR, RS
    CHERNEY, OE
    DETOURREIL, C
    DUMORA, D
    HARMON, R
    HERVIG, H
    KINGSBURY, B
    KISE, J
    ORBECK, T
    TANAKA, K
    TAY, R
    TOSKEY, G
    WIITANEN, D
    IEEE TRANSACTIONS ON POWER DELIVERY, 1995, 10 (02) : 924 - 933
  • [4] Analytical Assessment of Industrial Contamination Level on Outdoor High Voltage Insulators at Western Region of Peninsular Malaysia
    Ahmad, Ahmad S.
    Ahmed, Saad
    ICIAS 2007: INTERNATIONAL CONFERENCE ON INTELLIGENT & ADVANCED SYSTEMS, VOLS 1-3, PROCEEDINGS, 2007, : 934 - +
  • [5] Factors and Models of Pollution Flashover on High Voltage Outdoor Insulators: Review
    Salem, Ali A.
    Abd Rahman, R.
    Kamarudin, M. S.
    Othman, N. A.
    2017 3RD IEEE CONFERENCE ON ENERGY CONVERSION (CENCON), 2017, : 241 - 246
  • [6] Performance of novel high voltage outdoor thermoplastic elastomeric insulators
    Soundarajan, E
    Jackson, E
    King, A
    Sundararajan, R
    2003 ANNUAL REPORT CONFERENCE ON ELECTRICAL INSULATION AND DIELECTRIC PHENOMENA, 2003, : 422 - 425
  • [7] A review of artificial contamination withstand test methods of high voltage outdoor insulators
    Naderian, A
    Sanaye-Pasand, M
    Mohseni, H
    CONFERENCE RECORD OF THE 2004 IEEE INTERNATIONAL SYMPOSIUM ON ELECTRICAL INSULATION, 2004, : 284 - 287
  • [8] Pollution Flashover Characteristics of High-Voltage Outdoor Insulators: Analytical Study
    Salem, Ali Ahmed
    Abd Rahman, Rahisham
    Al-Ameri, Salem
    ARABIAN JOURNAL FOR SCIENCE AND ENGINEERING, 2022, 47 (03) : 2711 - 2729
  • [9] Pollution Flashover Characteristics of High-Voltage Outdoor Insulators: Analytical Study
    Ali Ahmed Salem
    Rahisham Abd Rahman
    Salem Al-Ameri
    Arabian Journal for Science and Engineering, 2022, 47 : 2711 - 2729
  • [10] Detection of pollution on high voltage insulators using ellipsometry
    Habli, MA
    OPTIK, 1999, 110 (04): : 191 - 193