Local damage detection by nonlinear coda wave interferometry combined with time reversal

被引:20
作者
Smagin, N. [1 ]
Trifonov, A. [1 ]
Matar, O. Bou [1 ]
Aleshin, V. V. [1 ,2 ]
机构
[1] Univ Lille, Univ Valenciennes, Cent Lille, ISEN,UMR 8520,IEMN,LIA,LICS,LEMAC, F-59000 Lille, France
[2] Tomsk State Univ, Tomsk 634050, Russia
关键词
Coda wave interferometry; Nondestructive testing; Time reversal; Pump-probe experiment; DIFFUSE ULTRASOUND; CHAOTIC CAVITIES; CONCRETE; ATTENUATION; VELOCITY; STRESS;
D O I
10.1016/j.ultras.2020.106226
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Coda wave interferometry (CWI) is a sensitive ultrasound method for the detection of weak and local changes in complex inhomogeneous media. In a nonlinear modification of the method discussed here, a high-frequency probe coda is compared to its replica obtained in the presence of low-frequency pumping. If, after the filtering-out of low frequencies, the coda signals are different, this is attributed to nonlinear pump-probe interaction induced by contact acoustical nonlinearity in the damaged zone. Actually, the CWI methods are used for global inspection of complex media, such as for example, concrete structures. In this work, a step forward is made; it consists in combining the CWI with the time-reversal (TR) technique in order to allow one to focus the pump wave on a selected area in the structure and to detect and localize a flaw. Time-reverse pump is possible only in pulsed mode due to the spatio-temporal wave compression. By this reason, the particularities of coda wave mixing in conventionally used continuous and pulsed pump mode are considered. It has been experimentally observed that an aftereffect of a pulsed pump provides a nonlinear interaction between pump and probe waves of a sufficient overall level for defect detection with TR. Finally, it was shown that a TR focusing even with the minimal available quality i.e., with only one transducer produces a sufficient contrast allowing to distinguish intact and damaged zones with nonlinear CWI.
引用
收藏
页数:12
相关论文
共 36 条
[1]   ORIGIN OF CODA WAVES - SOURCE, ATTENUATION, AND SCATTERING EFFECTS [J].
AKI, K ;
CHOUET, B .
JOURNAL OF GEOPHYSICAL RESEARCH, 1975, 80 (23) :3322-3342
[2]   Improving spatio-temporal focusing and source reconstruction through deconvolution [J].
Anderson, Brian E. ;
Douma, Johannes ;
Ulrich, T. J. ;
Snieder, Roel .
WAVE MOTION, 2015, 52 :151-159
[3]  
Chen B., 2018, ULTRASONICS, DOI [10.1016/j.ultras.2018, DOI 10.1016/J.ULTRAS.2018]
[4]   Numerical modeling modeling of ultrasonic coda wave interferometry in a multiple scattering medium with a localized nonlinear defect [J].
Chen, Guangzhi ;
Pageot, Damien ;
Legland, Jean-Baptiste ;
Abraham, Odile ;
Chekroun, Mathieu ;
Tournat, Vincent .
WAVE MOTION, 2017, 72 :228-243
[5]   One-channel time reversal of elastic waves in a chaotic 2D-silicon cavity [J].
Draeger, C ;
Fink, M .
PHYSICAL REVIEW LETTERS, 1997, 79 (03) :407-410
[6]   One-channel time-reversal in chaotic cavities: Experimental results [J].
Draeger, C ;
Aime, JC ;
Fink, M .
JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1999, 105 (02) :618-625
[7]   One-channel time-reversal in chaotic cavities: Theoretical limits [J].
Draeger, C ;
Fink, M .
JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1999, 105 (02) :611-617
[8]   Time-reversed acoustics [J].
Fink, M ;
Cassereau, D ;
Derode, A ;
Prada, C ;
Roux, P ;
Tanter, M ;
Thomas, JL ;
Wu, F .
REPORTS ON PROGRESS IN PHYSICS, 2000, 63 (12) :1933-1995
[9]   Amplitude and phase measurements of continuous diffuse fields for structural health monitoring of concrete structures [J].
Frojd, P. ;
Ulriksen, P. .
NDT & E INTERNATIONAL, 2016, 77 :35-41
[10]   Frequency selection for coda wave interferometry in concrete structures [J].
Frojd, Patrik ;
Ulriksen, Peter .
ULTRASONICS, 2017, 80 :1-8