A Web-based TelePACS using an asymmetric satellite system

被引:10
作者
Hwang, SC [1 ]
Lee, MH
机构
[1] Induk Inst Technol, Dept Broadcasting & Commun, Seoul, South Korea
[2] Yonsei Univ, Dept Elect & Comp Engn, Seoul 120749, South Korea
来源
IEEE TRANSACTIONS ON INFORMATION TECHNOLOGY IN BIOMEDICINE | 2000年 / 4卷 / 03期
关键词
Asymmetric satellite data communication system; (ASDCS); !text type='Java']Java[!/text] programming techniques; public telemedicine systems; remote image viewing systems; teleconsultation systems; teleeducation systems; TelePACS; Web browser; WWW-based TelePACS;
D O I
10.1109/4233.870031
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
We have developed a WWW-based TelePACS that can access every permitted PACS server via the Internet. Java programming techniques were used to implement the system, which can access and retrieve medical information and images through Web browsers only such as Netscape without specific tools. We also have developed a consolidator that performs as a manager to connect a conventional PACS server to a Web-based TelePACS server. We have developed the Asymmetric Satellite Data Communication System (ASDCS) as a fast communication system. The ASDCS uses a receive-only satellite link for data delivery and a terrestrial network for control communication. In conclusion we were able to develop a cost-effective and fast PACS using Web technology, Web technology expanded the scope of use for a dedicated PACS From intrahospital to public use.
引用
收藏
页码:212 / 215
页数:4
相关论文
共 19 条
[1]  
*ACR NEMA, 1993, ACRNEMA V3 0 DIG IM
[2]   Inter-hospital PACS designed for tele-radiology and tele-conference using a secured high speed network [J].
Ando, Y ;
Kitamura, M ;
Tsukamoto, N ;
Kawaguchi, O ;
Kunieda, E ;
Kubo, A ;
Kohda, E ;
Hiramatsu, K ;
Sakano, T ;
Fujii, T ;
Okumura, A ;
Furukawa, I ;
Suzuki, J ;
Ono, S .
MEDICAL IMAGING 1999 - PACS DESIGN AND EVALUATION: ENGINEERING AND CLINICAL ISSUES, 1999, 3662 :420-429
[3]  
ARORA V, 1993, TR962 CSHCN U MAR
[4]  
AUBRY F, 1991, P SOC PHOTO-OPT INS, V1446, P168, DOI 10.1117/12.45269
[5]   Lossy (15:1) JPEG compression of digital coronary angiograms does not limit detection of subtle morphological features [J].
Baker, WA ;
Hearne, SE ;
Spero, LA ;
Morris, KG ;
Harrington, RA ;
Sketch, MH ;
Behar, VS ;
Kong, YH ;
Peter, RH ;
Bashore, TM ;
Harrison, JK ;
Cusma, JT .
CIRCULATION, 1997, 96 (04) :1157-1164
[6]  
BARTSCH FR, 1993, P SOC PHOTO-OPT INS, V1899, P326, DOI 10.1117/12.152898
[7]   SATELLITES AND DEVELOPING-COUNTRIES [J].
CHASIA, H .
IEEE COMMUNICATIONS MAGAZINE, 1995, 33 (09) :110-112
[8]  
Cooper MD, 1998, J AM SOC INFORM SCI, V49, P903, DOI 10.1002/(SICI)1097-4571(199808)49:10<903::AID-ASI6>3.0.CO
[9]  
2-F
[10]  
FALK AD, 1994, SYSTEM DESIGN HYBRID