A retrospective study of silicone stent placement for management of anastomotic airway complications in lung transplant recipients: Short- and long-term outcomes

被引:65
作者
Dutau, Herve [1 ]
Cavailles, Arnaud [1 ]
Sakr, Lama [1 ]
Badier, Monique [2 ]
Gaubert, Jean-Yves [3 ,4 ]
Boniface, Stephanie [4 ]
Doddoli, Christophe [5 ]
Thomas, Pascal [5 ]
Reynaud-Gaubert, Martine [5 ]
机构
[1] Univ Mediterrannee, Assistance Publ Hop Marseille, Dept Thorac Endoscopy, Marseille, France
[2] Univ Mediterrannee, Assistance Publ Hop Marseille, Dept Clin Physiol, Marseille, France
[3] Univ Mediterrannee, Assistance Publ Hop Marseille, Dept Radiol, Marseille, France
[4] Univ Mediterrannee, Assistance Publ Hop Marseille, Dept Resp Med, Marseille, France
[5] Univ Mediterrannee, Assistance Publ Hop Marseille, Dept Thorac Surg, Marseille Lung Transplant Grp, Marseille, France
关键词
lung transplantation; airway stenting; bronchial stenting; bronchial stenosis; anastomotic complications; silicone stents; self-expandable metallic stents; EXPANDABLE METALLIC STENTS; FLEXIBLE BRONCHOSCOPY; BRONCHIAL STENOSIS; BENIGN;
D O I
10.1016/j.healun.2009.12.011
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BACKGROUND: Airway anastomotic complications remain a major cause of morbidity and mortality after lung transplantation (LT). Few data are available with regard to the use of silicone stents for these airway disorders. The aim of this retrospective study was to evaluate the clinical efficacy and safety of silicone stents for such an indication. METHODS: Data of adult lung transplant recipients who had procedures performed between January 1997 and December 2007 at our institution were reviewed retrospectively. We included patients with post-transplant airway complications who required bronchoscopic intervention with a silicone stent. RESULTS: In 17 of 117 (14.5%) LT recipients, silicone stents were inserted at a mean time of 165 (range 5 to 360) days after surgery in order to palliate 23 anastomotic airway stenoses. Symptomatic improvement was noted in all patients, and mean forced expiratory volume in 1 second (FEV1) increased by 672 +/- 496 ml < 0.001) after stent insertion. The stent-related complication rate was 0.13/patient per month. The latter consisted of obstructive granulomas (n = 10), mucus plugging (n = 7) and migration (n = 7), which were of mild to moderate severity and were successfully managed endoscopically. Mean stent duration was 266 days (range 24 to 1,407 days). Successful stent removal was achieved in 16 of 23 cases (69.5%) without recurrence of stenosis. Overall survival was similar in patients with and without airway complications (p = 0.36). CONCLUSIONS: Silicone stents allow clinical and lung function improvement in patients with LT-related airway complications. Stent-related complications were of mild to moderate severity, and were appropriately managed endoscopically. Permanent resolution of airway stenosis was obtained in most patients, allowing definitive stent removal without recurrence. J Heart Lung Transplant 2010;29:658-64 (C) 2010 International Society for Heart and Lung Transplantation. All rights reserved.
引用
收藏
页码:658 / 664
页数:7
相关论文
共 34 条
[1]   Airway complications after lung transplantation:: a review of 151 anastomoses [J].
Alvarez, A ;
Algar, J ;
Santos, F ;
Lama, R ;
Aranda, JL ;
Baamonde, C ;
López-Pujol, J ;
Salvatierra, A .
EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2001, 19 (04) :381-387
[2]   PULMONARY AND SYSTEMIC BLOOD-FLOW CONTRIBUTIONS TO UPPER AIRWAYS IN CANINE LUNG [J].
BARMAN, SA ;
ARDELL, JL ;
PARKER, JC ;
PERRY, ML ;
TAYLOR, AE .
AMERICAN JOURNAL OF PHYSIOLOGY, 1988, 255 (05) :H1130-H1135
[3]  
BISSON A, 1992, J THORAC CARDIOV SUR, V103, P40
[4]   On-Site Customization of Silicone Stents: Towards Optimal Palliation of Complex Airway Conditions [J].
Breen, David P. ;
Dutau, Herve .
RESPIRATION, 2009, 77 (04) :447-453
[5]   Ultraflex stents for the management of airway complications in lung transplant recipients [J].
Chhajed, PN ;
Malouf, MA ;
Tamm, M ;
Glanville, AR .
RESPIROLOGY, 2003, 8 (01) :59-64
[6]   Bronchial airway anastomotic complications after pediatric lung transplantation: Incidence, cause, management, and outcome [J].
Choong, CK ;
Sweet, SC ;
Zoole, JB ;
Guthrie, TJ ;
Mendeloff, EN ;
Haddad, FJ ;
Schuler, P ;
La Morena, MD ;
Huddleston, CB .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2006, 131 (01) :198-203
[7]   ENDOSCOPIC MANAGEMENT OF BRONCHIAL STENOSIS AFTER DOUBLE LUNG TRANSPLANTATION [J].
COLT, HG ;
JANSSEN, JP ;
DUMON, JF ;
NOIRCLERC, MJ .
CHEST, 1992, 102 (01) :10-16
[8]   Self-expandable metallic airway stent insertion employing flexible bronchoscopy - Preliminary results [J].
Dasgupta, A ;
Dolmatch, BL ;
Abi-Saleh, WJ ;
Mathur, PN ;
Mehta, AC .
CHEST, 1998, 114 (01) :106-109
[9]   Risk factors for airway complications within the first year after lung transplantation [J].
De Wauwer, Caroline Van ;
Van Raemdonck, Dirk ;
Verleden, Geert M. ;
Dupont, Lieven ;
De Leyn, Paul ;
Coosemans, Willy ;
Nafteux, Philippe ;
Lerut, Toni .
EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2007, 31 (04) :703-710
[10]  
DEHOYOS AL, 1992, J THORAC CARDIOV SUR, V103, P295