Validated simulation for LYSO:Ce scintillator based PET detector modules built on fully digital SiPM arrays

被引:4
作者
Jatekos, B. [1 ]
Gasparini, L. [2 ]
Lorincz, E. [1 ]
Erdei, G. [1 ]
机构
[1] Budapest Univ Technol & Econ, Dept Atom Phys, Budafoki Ut 8, H-1111 Budapest, Hungary
[2] Fdn Bruno Kessler, Ctr Mat & Microsyst, Integrated Radiat & Image Sensors, Via Sommar 18, I-38123 Trento, Italy
来源
JOURNAL OF INSTRUMENTATION | 2016年 / 11卷
关键词
Simulation methods and programs; Scintillators; scintillation and light emission processes (solid; gas and liquid scintillators); Gamma camera; SPECT; PET PET/CT; coronary CT angiography (CTA); Gamma detectors (scintillators; CZT; HPG; HgI etc); CRYSTAL; RESOLUTION; OUTPUT;
D O I
10.1088/1748-0221/11/03/P03028
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
In the recent years new digital photon counter devices (also known as silicon photomultipliers, SiPMs) were designed and manufactured to be used specifically in positron emission tomography (PET) scanners. These finely pixelated devices opened new opportunities in PET detector development, hence their application with monolithic scintillator crystals now are of particular interest. We worked out a simulation tool and a corresponding validation method to assist the optimization and characterization of such PET detector modules. During our work we concentrated on the simulation of SPADnet sensors and the LYSO:Ce scintillator material. Validation of our algorithms combines measurements and simulations performed on UV-excited detector modules. In this paper we describe the operation of the simulation method in detail and present the validation scheme for two demonstrative PET detector-like modules: one built of a scintillator with black-painted faces and another with polished faces. By evaluating the results we show that the shape deviation of the average light distributions is lower than 13%, and the pixel count statistics follow Poisson distribution for both measurement and simulation. The calculated total count values have less than 10% deviation from the measured ones.
引用
收藏
页数:28
相关论文
共 32 条
  • [1] Measurement of propagation time dispersion in a scintillator
    Achenbach, P.
    Gayoso, C. Ayerbe
    Bernauer, J.
    Boehm, R.
    Distler, M. O.
    Doria, L.
    Friedrich, J.
    Merkel, H.
    Mueller, U.
    Nungesser, L.
    Pochodzalla, J.
    Majos, S. Sanchez
    Schlimme, S.
    Walcher, Th.
    Weinriefer, M.
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2007, 578 (01) : 253 - 260
  • [2] GEANT4-a simulation toolkit
    Agostinelli, S
    Allison, J
    Amako, K
    Apostolakis, J
    Araujo, H
    Arce, P
    Asai, M
    Axen, D
    Banerjee, S
    Barrand, G
    Behner, F
    Bellagamba, L
    Boudreau, J
    Broglia, L
    Brunengo, A
    Burkhardt, H
    Chauvie, S
    Chuma, J
    Chytracek, R
    Cooperman, G
    Cosmo, G
    Degtyarenko, P
    Dell'Acqua, A
    Depaola, G
    Dietrich, D
    Enami, R
    Feliciello, A
    Ferguson, C
    Fesefeldt, H
    Folger, G
    Foppiano, F
    Forti, A
    Garelli, S
    Giani, S
    Giannitrapani, R
    Gibin, D
    Cadenas, JJG
    González, I
    Abril, GG
    Greeniaus, G
    Greiner, W
    Grichine, V
    Grossheim, A
    Guatelli, S
    Gumplinger, P
    Hamatsu, R
    Hashimoto, K
    Hasui, H
    Heikkinen, A
    Howard, A
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2003, 506 (03) : 250 - 303
  • [3] [Anonymous], SIMULATION MONTE CAR
  • [4] Braga L.H.C., 2012, P IEEE NUCL SCI S ME
  • [5] A Fully Digital 8 x 16 SiPM Array for PET Applications With Per-Pixel TDCs and Real-Time Energy Output
    Braga, Leo H. C.
    Gasparini, Leonardo
    Grant, Lindsay
    Henderson, Robert K.
    Massari, Nicola
    Perenzoni, Matteo
    Stoppa, David
    Walker, Richard
    [J]. IEEE JOURNAL OF SOLID-STATE CIRCUITS, 2014, 49 (01) : 301 - 314
  • [6] SPADnet: Embedded coincidence in a smart sensor network for PET applications
    Bruschini, C.
    Charbon, E.
    Veerappan, C.
    Braga, L. H. C.
    Massari, N.
    Perenzoni, M.
    Gasparini, L.
    Stoppa, D.
    Walker, R.
    Erdogan, A.
    Henderson, R. K.
    East, S.
    Grant, L.
    Jatekos, B.
    Ujhelyi, F.
    Erdei, G.
    Loerincz, E.
    Andre, L.
    Maingault, L.
    Reboud, V.
    Verger, L.
    d'Aillon, E. Gros
    Major, P.
    Papp, Z.
    Nemeth, G.
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2014, 734 : 122 - 126
  • [7] *COMM MATH PHYS EM, 1996, MATH PHYS EM BIOM IM
  • [8] Investigation of a continuous crystal PSAPD-based gamma camera
    Despres, Philippe
    Barber, William C.
    Funk, Tobias
    McClish, Mickel
    Shah, Kanai S.
    Hasegawa, Bruce H.
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2006, 53 (03) : 1643 - 1649
  • [9] Refractive index measurement of cerium-doped LuxY2-x,SiO5 single crystal
    Erdei, Gabor
    Berze, Noemi
    Peter, Agnes
    Jatekos, Balazs
    Lorincz, Emoke
    [J]. OPTICAL MATERIALS, 2012, 34 (05) : 781 - 785
  • [10] Feynman R. P., 1998, Quantum Electrodynamics (Advanced Books Classics)