Microresonator mass sensors for detection of Bacillus anthracis Sterne spores in air and water

被引:69
作者
Davila, Angelica P.
Jang, Jaesung
Gupta, Amit K.
Walter, Tom
Aronson, Arthur
Bashir, Rashid [1 ]
机构
[1] Purdue Univ, Sch Elect & Comp Engn, Birck Nanotechnol Ctr, Lab Integrated Biomed Micro Nanotechnol & A, W Lafayette, IN 47907 USA
[2] Purdue Univ, Sch Elect & Comp Engn, Bindley Biosci Ctr, Lab Integrated Biomed Micro Nanotechnol & A, W Lafayette, IN 47907 USA
[3] Purdue Univ, Dept Biol Sci, W Lafayette, IN 47907 USA
[4] Purdue Univ, Weldon Sch Biomed Engn, W Lafayette, IN 47907 USA
关键词
microcantilever; resonant mass sensor; spore detection; viscous medium;
D O I
10.1016/j.bios.2007.01.012
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Towards the goal of developing a real-time monitoring device for microorganisms, we demonstrate the use of microcantilevers as resonant mass sensors for detection of Bacillus anthracis Sterne spores in air and liquid. The detection scheme was based on measuring resonant frequency decrease driven by thermally induced oscillations, as a result of the added mass of the spores with the use of a laser Doppler vibrometer (LDV). Viscous effects were investigated by comparing measurements in air and deionized (DI) water along with theoretical values. Moreover, biological experiments were performed which involved suspending spores onto the cantilevers and performing mass detection in air and water. For detection of spores in water, the cantilevers were functionalized with antibodies in order to fix the spores onto the surface. We demonstrate that as few as 50 spores on the cantilever can be detected in water using the thermal noise as excitation source. Measurement sensitivity of 9.23 Hz/fg for air and 0.1 Hz/fg for water were obtained. These measurements were compared with theoretical values and sources of improvement in cantilever sensitivity in a viscous medium were also discussed. It is expected that by driving the cantilevers and using higher order modes, detection of a single spore in liquids should be achievable. (c) 2007 Elsevier B.V. All rights reserved.
引用
收藏
页码:3028 / 3035
页数:8
相关论文
共 23 条
[1]  
[Anonymous], 1963, 2 DTMB SW RES I
[2]   BACTERIAL SPORE HEAT-RESISTANCE CORRELATED WITH WATER-CONTENT, WET DENSITY, AND PROTOPLAST SPOROPLAST VOLUME RATIO [J].
BEAMAN, TC ;
GREENAMYRE, JT ;
CORNER, TR ;
PANKRATZ, HS ;
GERHARDT, P .
JOURNAL OF BACTERIOLOGY, 1982, 150 (02) :870-877
[3]   Micromechanical mass sensors for biomolecular detection in a physiological environment [J].
Braun, T ;
Barwich, V ;
Ghatkesar, MK ;
Bredekamp, AH ;
Gerber, C ;
Hegner, M ;
Lang, HP .
PHYSICAL REVIEW E, 2005, 72 (03)
[4]   Suspended microchannel resonators for biomolecular detection [J].
Burg, TP ;
Manalis, SR .
APPLIED PHYSICS LETTERS, 2003, 83 (13) :2698-2700
[5]   Evaluation of the use of PCR and reverse transcriptase PCR for detection of pathogenic bacteria in biosolids from anaerobic digestors and aerobic composters [J].
Burtscher, C ;
Wuertz, S .
APPLIED AND ENVIRONMENTAL MICROBIOLOGY, 2003, 69 (08) :4618-4627
[6]   Piezoelectric-excited millimeter-sized cantilever (PEMC) sensors detect Bacillus anthracis at 300 spores/mL [J].
Campbell, GA ;
Mutharasan, R .
BIOSENSORS & BIOELECTRONICS, 2006, 21 (09) :1684-1692
[7]   Experimental validation of theoretical models for the frequency response of atomic force microscope cantilever beams immersed in fluids [J].
Chon, JWM ;
Mulvaney, P ;
Sader, JE .
JOURNAL OF APPLIED PHYSICS, 2000, 87 (08) :3978-3988
[8]   Ultimate limits to inertial mass sensing based upon nanoelectromechanical systems [J].
Ekinci, KL ;
Yang, YT ;
Roukes, ML .
JOURNAL OF APPLIED PHYSICS, 2004, 95 (05) :2682-2689
[9]   Micromechanical oscillators as rapid biosensor for the detection of active growth of Escherichia coli [J].
Gfeller, KY ;
Nugaeva, N ;
Hegner, M .
BIOSENSORS & BIOELECTRONICS, 2005, 21 (03) :528-533
[10]   Detection of bacterial cells and antibodies using surface micromachined thin silicon cantilever resonators [J].
Gupta, A ;
Akin, D ;
Bashir, R .
JOURNAL OF VACUUM SCIENCE & TECHNOLOGY B, 2004, 22 (06) :2785-2791