A compact NIR fiber-optic diode laser spectrometer for CO andCO2:: analysis of observed 2f wavelength modulation spectroscopy line shapes

被引:49
作者
Engelbrecht, R [1 ]
机构
[1] Univ Erlangen Nurnberg, Lehrstuhl Hochfrequenztech, D-91058 Erlangen, Germany
关键词
tunable diode laser; near infrared; carbon monoxide; carbon dioxide; optical fiber; noise analysis; line shapes; wavelength modulation spectroscopy;
D O I
10.1016/j.saa.2003.11.033
中图分类号
O433 [光谱学];
学科分类号
0703 ; 070302 ;
摘要
A compact fiber-optic diode laser spectrometer for the measurement of CO and CO2 gas concentrations in the near infrared around 1580 nm is described. By use of a balanced receiver to suppress diode laser intensity noise a sensitivity of 6.4 x 10(-7) at 1 Hz system bandwidth was achieved. At a reduced pressure of 80 hPa this equals to a detection limit of 5.1 ppm CO and 9.1 ppm CO, with 1 m absorption path length. The observed line shapes of the 2f wavelength modulation spectroscopy (WMS) scheme are analyzed theoretically and experimentally. Accurate measurements of magnitude and phase of the diode laser frequency and intensity modulation responses were found critically for modeling the observed line shapes. In situ measurements of gas dissociation processes inside of a medium-power carbon dioxide laser are presented as an application example. (C) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:3291 / 3298
页数:8
相关论文
共 28 条
[1]   POWER SCALING OF LARGE-AREA TRANSVERSE RADIO-FREQUENCY DISCHARGE CO2-LASERS [J].
ABRAMSKI, KM ;
COLLEY, AD ;
BAKER, HJ ;
HALL, DR .
APPLIED PHYSICS LETTERS, 1989, 54 (19) :1833-1835
[2]   Diode laser absorption sensors for gas-dynamic and combustion flows [J].
Allen, MG .
MEASUREMENT SCIENCE AND TECHNOLOGY, 1998, 9 (04) :545-562
[3]  
[Anonymous], LASER REMOTE CHEM AN
[4]   COLLISION DYNAMICAL INFORMATION FROM PRESSURE BROADENING MEASUREMENTS - APPLICATION TO CARBON-MONOXIDE [J].
BELBRUNO, JJ ;
GELFAND, J ;
RABITZ, H .
JOURNAL OF CHEMICAL PHYSICS, 1983, 78 (06) :3990-3998
[5]   LINEWIDTHS OF CARBON-MONOXIDE SELF-BROADENING AND BROADENED BY ARGON AND NITROGEN [J].
BOUANICH, JP ;
HAEUSLER, C .
JOURNAL OF QUANTITATIVE SPECTROSCOPY & RADIATIVE TRANSFER, 1972, 12 (04) :695-&
[6]   ACCURATE MEASUREMENTS OF PRESSURE-BROADENED LINEWIDTHS IN A TRANSVERSELY EXCITED CO2 DISCHARGE [J].
BRIMACOMBE, RK ;
REID, J .
IEEE JOURNAL OF QUANTUM ELECTRONICS, 1983, 19 (11) :1668-1673
[7]   TUNABLE DIODE-LASER FREQUENCY-MODULATION SPECTROSCOPY THROUGH AN OPTICAL FIBER - HIGH-SENSITIVITY DETECTION OF WATER-VAPOR [J].
CARLISLE, CB ;
COOPER, DE .
APPLIED PHYSICS LETTERS, 1990, 56 (09) :805-807
[8]   TRACE GAS-DETECTION USING 1.3-MU-M INGAASP DIODE-LASER TRANSMITTER MODULES [J].
CASSIDY, DT .
APPLIED OPTICS, 1988, 27 (03) :610-614
[9]  
CLARK R, 1995, SPECTROSCOPY ENV SCI, V24
[10]  
Demtroder W., 2000, LASERSPEKTROSKOPIE