Electrical Characterisitics of ferritin cores Investegated by Kelvin Probe Force Microscopy

被引:2
作者
Yamamoto, Shin-ichi [1 ]
Kobayashi, Kei [2 ]
Yamada, Hirofumi [2 ]
Yoshioka, Hideki [3 ]
Uraoka, Yukiharu [4 ]
Fuyuki, Takashi [4 ]
Yamashita, Ichiro [5 ]
机构
[1] Kobe City Coll Technol, Dept Elect Engn, Nishi Ku, 8-3 Gakuen Higashimachi, Kobe, Hyogo 6512194, Japan
[2] Kyoto Univ, Dept Elect Sci & Engn, Kyoto 6158510, Japan
[3] Hyogo Prefectural Inst Technol, Yukihira Cho, Suma Ku, Kobe, Hyogo 6540037, Japan
[4] Nara Womens Univ, Dept Mat Sci, Nara 6300192, Japan
[5] Matsushita Elect Ind Co Ltd, Kyoto 6190237, Japan
来源
PROCEEDINGS OF THE 17TH INTERNATIONAL VACUUM CONGRESS/13TH INTERNATIONAL CONFERENCE ON SURFACE SCIENCE/INTERNATIONAL CONFERENCE ON NANOSCIENCE AND TECHNOLOGY | 2008年 / 100卷
关键词
D O I
10.1088/1742-6596/100/5/052004
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
We fabricated Fe (iron metal) cores structure by using a low energy Ar+ ion beam. A monolayer of ferritin molecule (Fe2O3 : iron oxide) was adsorbed on the thermal silicon oxide layer. The bombardment energy was optimized using Ar gas by changing the input power after the protein of the monolayer was eliminated with UV/O-3. Though it was resulted in a poor reduction when the time of ion beam was less than 30 sec, Ar+ ion beam enabled completely reduction when the time of ion beam was in 60 sec. We reduced the core particles to conductive Fe nanodots. X-ray photoelectron spectroscopy (XPS) measurements confirmed the reduction of the cores. As a result, the diameter of the ferritin nano-structure was 7 nm, which was not identical to that of the iron core in the ferritin after ion beam. Additionally, the Kelvin Probe Force microscopy (KFM) profile was not almost identical between Fe2O3 and Fe cores. It is very difficult for conventional Ar+ beam processes to fabricate such fine structure of Fe cores, because the high energy ions enhanced the bombardment damage of the iron core in the conventional reduction processes. The results that the change of lattice constant from 0.25 to 0.2 nm corresponds from ferrihydrite (110) to alpha-Fe(111), respectively, which suggests the ferrihydrite cores reduced to Fe nanodots after ion beam process. Furthurmore, the diameter of the ferritin core decreased from 7 nm to 5 nm after the ion beam process.
引用
收藏
页数:4
相关论文
共 50 条
[31]   Three-Dimensional Kelvin Probe Force Microscopy [J].
Geng, Junyuan ;
Zhang, Hao ;
Meng, Xianghe ;
Gao, Haibo ;
Rong, Weibin ;
Xie, Hui .
ACS APPLIED MATERIALS & INTERFACES, 2022, 14 (28) :32719-32728
[32]   Kelvin probe force microscopy under ambient conditions [J].
Amirhossein Zahmatkeshsaredorahi ;
Ruben Millan-Solsona ;
Devon S. Jakob ;
Liam Collins ;
Xiaoji G. Xu .
Nature Reviews Methods Primers, 5 (1)
[33]   Kelvin probe force microscopy for perovskite solar cells [J].
Kang, Zhuo ;
Si, Haonan ;
Shi, Mingyue ;
Xu, Chenzhe ;
Fan, Wenqiang ;
Ma, Shuangfei ;
Kausar, Ammarah ;
Liao, Qingliang ;
Zhang, Zheng ;
Zhang, Yue .
SCIENCE CHINA-MATERIALS, 2019, 62 (06) :776-789
[34]   Kelvin probe force microscopy under ambient conditions [J].
Nature Reviews Methods Primers, 5 (1)
[35]   Atomic and Kelvin probe force microscopy of thin films [J].
Alessandrini, A ;
Valdrè, U .
PROCEEDINGS OF THE 5TH MULTINATIONAL CONGRESS ON ELECTRON MICROSCOPY, 2001, :553-554
[36]   Dual-heterodyne Kelvin probe force microscopy [J].
Grevin, Benjamin ;
Husainy, Fatima ;
Aldakov, Dmitry ;
Aumaitre, Cyril .
BEILSTEIN JOURNAL OF NANOTECHNOLOGY, 2023, 14 :1068-1084
[37]   Kelvin probe force microscopy of semiconductor surface defects [J].
Rosenwaks, Y ;
Shikler, R ;
Glatzel, T ;
Sadewasser, S .
PHYSICAL REVIEW B, 2004, 70 (08) :085320-1
[38]   Space Charge Measurements with Kelvin Probe Force Microscopy [J].
Faliya, Kapil ;
Kliem, Herbert ;
Dias, Carlos J. .
IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2017, 24 (03) :1913-1922
[39]   The role of the cantilever in Kelvin probe force microscopy measurements [J].
Elias, George ;
Glatzel, Thilo ;
Meyer, Ernst ;
Schwarzman, Alex ;
Boag, Amir ;
Rosenwaks, Yossi .
BEILSTEIN JOURNAL OF NANOTECHNOLOGY, 2011, 2 :252-260
[40]   Signal reversal in Kelvin-probe force microscopy [J].
Mesquida, P. ;
Kohl, D. ;
Schitter, G. .
REVIEW OF SCIENTIFIC INSTRUMENTS, 2019, 90 (11)