Electrical Characterisitics of ferritin cores Investegated by Kelvin Probe Force Microscopy

被引:2
作者
Yamamoto, Shin-ichi [1 ]
Kobayashi, Kei [2 ]
Yamada, Hirofumi [2 ]
Yoshioka, Hideki [3 ]
Uraoka, Yukiharu [4 ]
Fuyuki, Takashi [4 ]
Yamashita, Ichiro [5 ]
机构
[1] Kobe City Coll Technol, Dept Elect Engn, Nishi Ku, 8-3 Gakuen Higashimachi, Kobe, Hyogo 6512194, Japan
[2] Kyoto Univ, Dept Elect Sci & Engn, Kyoto 6158510, Japan
[3] Hyogo Prefectural Inst Technol, Yukihira Cho, Suma Ku, Kobe, Hyogo 6540037, Japan
[4] Nara Womens Univ, Dept Mat Sci, Nara 6300192, Japan
[5] Matsushita Elect Ind Co Ltd, Kyoto 6190237, Japan
来源
PROCEEDINGS OF THE 17TH INTERNATIONAL VACUUM CONGRESS/13TH INTERNATIONAL CONFERENCE ON SURFACE SCIENCE/INTERNATIONAL CONFERENCE ON NANOSCIENCE AND TECHNOLOGY | 2008年 / 100卷
关键词
D O I
10.1088/1742-6596/100/5/052004
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
We fabricated Fe (iron metal) cores structure by using a low energy Ar+ ion beam. A monolayer of ferritin molecule (Fe2O3 : iron oxide) was adsorbed on the thermal silicon oxide layer. The bombardment energy was optimized using Ar gas by changing the input power after the protein of the monolayer was eliminated with UV/O-3. Though it was resulted in a poor reduction when the time of ion beam was less than 30 sec, Ar+ ion beam enabled completely reduction when the time of ion beam was in 60 sec. We reduced the core particles to conductive Fe nanodots. X-ray photoelectron spectroscopy (XPS) measurements confirmed the reduction of the cores. As a result, the diameter of the ferritin nano-structure was 7 nm, which was not identical to that of the iron core in the ferritin after ion beam. Additionally, the Kelvin Probe Force microscopy (KFM) profile was not almost identical between Fe2O3 and Fe cores. It is very difficult for conventional Ar+ beam processes to fabricate such fine structure of Fe cores, because the high energy ions enhanced the bombardment damage of the iron core in the conventional reduction processes. The results that the change of lattice constant from 0.25 to 0.2 nm corresponds from ferrihydrite (110) to alpha-Fe(111), respectively, which suggests the ferrihydrite cores reduced to Fe nanodots after ion beam process. Furthurmore, the diameter of the ferritin core decreased from 7 nm to 5 nm after the ion beam process.
引用
收藏
页数:4
相关论文
共 50 条
  • [21] Probing the Local Electrical Properties of Al(In,Ga)N by Kelvin Probe Force Microscopy
    Minj, Albert
    Ben Ammar, Hichem
    Cros, Ana
    Garro, Nuria
    Gamarra, Piero
    Delage, Sylvain L.
    Ruterana, Pierre
    [J]. PHYSICA STATUS SOLIDI B-BASIC SOLID STATE PHYSICS, 2018, 255 (05):
  • [22] Characterization of electrical properties of GaAs nanowires and planar heterostructures by Kelvin probe force microscopy
    Matheson, Graham
    Geelhaar, Lutz
    Hellmann, Martin
    Herranz, Jesus
    [J]. ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2018, 255
  • [23] Peak Force Infrared-Kelvin Probe Force Microscopy
    Jakob, Devon S.
    Wang, Haomin
    Zeng, Guanghong
    Otzen, Daniel E.
    Yan, Yong
    Xu, Xiaoji G.
    [J]. ANGEWANDTE CHEMIE-INTERNATIONAL EDITION, 2020, 59 (37) : 16083 - 16090
  • [24] Surface potential evaluations of ferritin nanodots by Kelvin force microscopy
    Department of Electrical Engineering, Kobe City College of Technology, 8-3, Gakuen-higashimachi, Nishi-ku, Kobe, 651-2194, Japan
    不详
    不详
    不详
    不详
    [J]. J. Scanning Probe Microsc., 2008, 1-2 (13-18):
  • [25] Elemental Identification by Combining Atomic Force Microscopy and Kelvin Probe Force Microscopy
    Schulz, Fabian
    Ritala, Juha
    Krejci, Ondrej
    Seitsonen, Ari Paavo
    Foster, Adam S.
    Liljeroth, Peter
    [J]. ACS NANO, 2018, 12 (06) : 5274 - 5283
  • [26] AFM tip characterization by Kelvin probe force microscopy
    Barth, C.
    Hynninen, T.
    Bieletzki, M.
    Henry, C. R.
    Foster, A. S.
    Esch, F.
    Heiz, U.
    [J]. NEW JOURNAL OF PHYSICS, 2010, 12
  • [27] Signal amplitude and sensitivity of the Kelvin probe force microscopy
    Ouisse, T
    Martins, F
    Stark, M
    Huant, S
    Chevrier, J
    [J]. APPLIED PHYSICS LETTERS, 2006, 88 (04) : 1 - 3
  • [28] Dual-heterodyne Kelvin probe force microscopy
    Grévin B.
    Husainy F.
    Aldakov D.
    Aumaître C.
    [J]. Beilstein Journal of Nanotechnology, 2023, 14 : 1068 - 1084
  • [29] The influence of surface topography on Kelvin probe force microscopy
    Sadewasser, S.
    Leendertz, C.
    Streicher, F.
    Lux-Steiner, M. Ch
    [J]. NANOTECHNOLOGY, 2009, 20 (50)
  • [30] The effect of sample resistivity on Kelvin probe force microscopy
    Weymouth, A. J.
    Giessibl, F. J.
    [J]. APPLIED PHYSICS LETTERS, 2012, 101 (21)