FDI oriented modeling of an experimental SOFC system, model validation and simulation of faulty states

被引:46
作者
Sorce, A. [1 ]
Greco, A. [1 ]
Magistri, L. [1 ]
Costamagna, P. [2 ]
机构
[1] Univ Genoa, Polytech Sch, Thermochem Power Grp TPG DIME, I-16145 Genoa, Italy
[2] Univ Genoa, Polytech Sch, Thermochem Power Grp TPG DICCA, I-16145 Genoa, Italy
关键词
SOFC; SOFC plant; Modeling; Fault implantation; FDI; OXIDE FUEL-CELL; CYCLES IRSOFC-GT; PART II; DIAGNOSIS METHODOLOGIES; QUANTITATIVE MODEL; DEGRADATION; PERFORMANCE; ANODE; ELECTRODES; STACKS;
D O I
10.1016/j.apenergy.2014.03.074
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
We present here a model we have established for a laboratory-size SOFC system. Model equations are presented and discussed, together with an extensive model validation, carried out in both steady state and transient operating conditions. The validated model is then used to simulate four classes of system faults, i.e. air leakage, fuel leakage, SOFC degradation and reformer degradation. When the different faults occur, the physico-chemical operating parameters of the system vary in a different manner, and our main objective is to understand their behavior. For example, for the system under analysis, SOFC degradation and fuel leakage cause a decrease of the gas discharge temperature, while reformer degradation causes an increase of the same parameter. The results of the fault analysis are described and discussed, and are reported in such a way to provide a basis for the development of an FDI tool based on pattern recognition techniques. (C) 2014 Elsevier Ltd. All rights reserved.
引用
收藏
页码:894 / 908
页数:15
相关论文
共 70 条
[1]   Review on modeling development for multiscale chemical reactions coupled transport phenomena in solid oxide fuel cells [J].
Andersson, Martin ;
Yuan, Jinliang ;
Sunden, Bengt .
APPLIED ENERGY, 2010, 87 (05) :1461-1476
[2]  
[Anonymous], 2004, FUEL CELL HDB, VSeventh
[3]  
Arsie I., 2010, P ASME 2010 8 INT FU
[4]   Incorporating available micro gas turbines and fuel cell: Matching considerations and performance evaluation [J].
Bakalis, Diamantis P. ;
Stamatis, Anastassios G. .
APPLIED ENERGY, 2013, 103 :607-617
[5]   Part load operation of a SOFC/GT hybrid system: Dynamic analysis [J].
Barelli, L. ;
Bidini, G. ;
Ottaviano, A. .
APPLIED ENERGY, 2013, 110 :173-189
[6]   Diagnosis methodology and technique for solid oxide fuel cells: A review [J].
Barelli, L. ;
Barluzzi, E. ;
Bidini, G. .
INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2013, 38 (12) :5060-5074
[7]  
Behling NH, 2013, FUEL CELLS: CURRENT TECHNOLOGY CHALLENGES AND FUTURE RESEARCH NEEDS, P1
[8]   A Review of Solid Oxide Fuel Cell (SOFC) Dynamic Models [J].
Bhattacharyya, Debangsu ;
Rengaswamy, Raghunathan .
INDUSTRIAL & ENGINEERING CHEMISTRY RESEARCH, 2009, 48 (13) :6068-6086
[9]  
Bossel U., 1992, International Energy Agency SOFC task report
[10]  
Bove R, 2008, FUEL CELL HYDRO ENER, V1, P1, DOI 10.1007/978-1-4020-6995-6