Long-term results (>1 year) in 19 dogs treated with MicroPulse transscleral diode cyclophotocoagulation for refractory glaucoma

被引:4
作者
Story, Brett D. [1 ]
Sapienza, John S. [1 ]
Di Girolamo, Nicola [2 ]
Kim, Kay [1 ]
机构
[1] Long Isl Vet Specialists, 163 S Serv Rd, Plainview, NY 11803 USA
[2] Oklahoma State Univ, Coll Vet Med, Stillwater, OK 74078 USA
关键词
canine; cyclophotocoagulation; diode laser; glaucoma; MicroPulse; TSCP; LASER CYCLOPHOTOCOAGULATION; NEODYMIUM-YTTRIUM; ADULT GLAUCOMA; CILIARY BODY; GONIOIMPLANTATION; CYCLOABLATION; ALUMINUM;
D O I
10.1111/vop.12895
中图分类号
S85 [动物医学(兽医学)];
学科分类号
0906 ;
摘要
Objective To report the long-term (>1 year) outcome of MicroPulse transscleral diode cyclophotocoagulation (MP-TSCP) in dogs. Animals Studied Client owned dogs that underwent MP-TSCP at a veterinary referral center. Procedure Retrospective study of 19 dogs treated with MP-TSCP. Dogs were evaluated at a median follow-up time of 30.5 months postoperatively. Reported outcomes were intraocular pressure (IOP), retention or loss of vision, number of medications, and additional procedures performed. Variables associated with time to treatment failure were evaluated. Results Data from 19 dogs (24 eyes) was available. Median laser settings employed were 140 s and 2200 mW at 31.3% duty cycle. Long-term postoperative IOP was lower than preoperative IOP values (14 mmHg (IQR = 22 mmHg, range: 4-52 mmHg) versus 30 mmHg (IQR = 31 mmHg, range: 8-62 mmHg), respectively). Laser settings >2000 mW were associated with a significantly longer time to reported failure. MP-TSCP was the sole therapy performed in 16/24 eyes resulting in long-term IOP control in 13/24 eyes and retention of vision in 6 of the 14 sighted eyes. Repeat MP-TSCP was performed in 10/24 eyes. Eight of 24 eyes required additional procedures with long-term IOP control in 4/8 eyes. Conclusions MicroPulse transscleral diode cyclophotocoagulation can be an effective treatment for refractory glaucoma in select cases. Higher laser settings increased time to reported failure, whereas age, glaucoma type, and preoperative IOP did not affect survival. MP-TSCP as sole therapy or coupled with additional glaucoma procedures controlled the IOP in 70% of cases.
引用
收藏
页码:572 / 581
页数:10
相关论文
共 38 条
  • [1] Micropulse versus continuous wave transscleral diode cyclophotocoagulation in refractory glaucoma: a randomized exploratory study
    Aquino, Maria Cecilia D.
    Barton, Keith
    Tan, Anna Marie W. T.
    Sng, Chelvin
    Li, Xiang
    Loon, Seng Chee
    Chew, Paul T. K.
    [J]. CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2015, 43 (01) : 40 - 46
  • [2] Barac Ramona, 2018, Rom J Ophthalmol, V62, P144
  • [3] Bentley E, 1999, J AM VET MED ASSOC, V215, P1469
  • [4] Comparisons against baseline within randomised groups are often used and can be highly misleading
    Bland, J. Martin
    Altman, Douglas G.
    [J]. TRIALS, 2011, 12
  • [5] Surgical Treatment of Canine Glaucoma Cyclodestructive Techniques
    Bras, Dineli
    Maggio, Federica
    [J]. VETERINARY CLINICS OF NORTH AMERICA-SMALL ANIMAL PRACTICE, 2015, 45 (06) : 1283 - +
  • [6] Cook C, 1997, VET COMP OPHTHALMOL, V7, P148
  • [7] CSC, 1997, VET CLIN N AM SMALL, V27, P1117
  • [8] Micropulse Cyclophotocoagulation: Initial Results in Refractory Glaucoma
    Emanuel, Matthew E.
    Grover, Davinder S.
    Fellman, Ronald L.
    Godfrey, David G.
    Smith, Oluwatosin
    Butler, Michelle R.
    Kornmann, Helen L.
    Feuer, William J.
    Goyal, Swati
    [J]. JOURNAL OF GLAUCOMA, 2017, 26 (08) : 726 - 729
  • [9] Histologic effects of MicroPulse™ transscleral cyclophotocoagulation in normal equine eyes
    Foote, Braidee C.
    Smith, Jodi D.
    Allbaugh, Rachel A.
    Sebbag, Lionel
    [J]. VETERINARY OPHTHALMOLOGY, 2021, 24 (01) : 59 - 70
  • [10] Fudemberg SJ, 2008, Invest Ophthalmol Visual Sci, V49, P1236