New set of design rules for resonant refractive index sensors enabled by FFT based processing of the measurement data

被引:21
作者
Gounaridis, Lefteris [1 ]
Groumas, Panos [1 ]
Schreuder, Erik [2 ]
Heideman, Rene [2 ]
Avramopoulos, Hercules [1 ]
Kouloumentas, Christos [1 ]
机构
[1] Natl Tech Univ Athens, Athens 15573, Greece
[2] LioniX BV, NL-2083 Enschede, Netherlands
关键词
SILICON-ON-INSULATOR; MICRORING RESONATORS; BIOCHEMICAL SENSOR; RING RESONATORS; FIBER;
D O I
10.1364/OE.24.007611
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
It is still a common belief that ultra-high quality-factors (Q-factors) are a prerequisite in optical resonant cavities for high refractive index resolution and low detection limit in biosensing applications. In combination with the ultra-short steps that are necessary when the measurement of the resonance shift relies on the wavelength scanning of a laser source and conventional methods for data processing, the high Q-factor requirement makes these biosensors extremely impractical. In this work we analyze an alternative processing method based on the fast-Fourier transform, and show through Monte-Carlo simulations that improvement by 2-3 orders of magnitude can be achieved in the resolution and the detection limit of the system in the presence of amplitude and spectral noise. More significantly, this improvement is maximum for low Q-factors around 104 and is present also for high intra-cavity losses and large scanning steps making the designs compatible with the low-cost aspect of lab-on-a-chip technology. Using a micro-ring resonator as model cavity and a system design with low Q-factor (104), low amplitude transmission (0.85) and relatively large scanning step (0.25 pm), we show that resolution close to 0.01 pm and detection limit close to 10(-7) RIU can be achieved improving the sensing performance by more than 2 orders of magnitude compared to the performance of systems relying on a simple peak search processing method. The improvement in the limit of detection is present even when the simple method is combined with ultra-high Q-factors and ultra-short scanning steps due to the trade-off between the system resolution and sensitivity. Early experimental results are in agreement with the trends of the numerical studies. (C) 2016 Optical Society of America
引用
收藏
页码:7611 / 7632
页数:22
相关论文
共 32 条
[1]  
Agrawal G.P., 2002, Fiber-Optic Communication Systems
[2]   Heavy water detection using ultra-high-Q microcavities [J].
Armani, Andrea M. ;
Vahala, Kerry J. .
OPTICS LETTERS, 2006, 31 (12) :1896-1898
[3]   Slot-waveguide biochemical sensor [J].
Barrios, Carlos A. ;
Gylfason, Kristinn B. ;
Sanchez, Benito ;
Griol, Amadeu ;
Sohlstroem, H. ;
Holgado, M. ;
Casquel, R. .
OPTICS LETTERS, 2007, 32 (21) :3080-3082
[4]   Silicon microring resonators [J].
Bogaerts, Wim ;
De Heyn, Peter ;
Van Vaerenbergh, Thomas ;
De Vos, Katrien ;
Selvaraja, Shankar Kumar ;
Claes, Tom ;
Dumon, Pieter ;
Bienstman, Peter ;
Van Thourhout, Dries ;
Baets, Roel .
LASER & PHOTONICS REVIEWS, 2012, 6 (01) :47-73
[5]   Polymer microring resonators for biochemical sensing applications [J].
Chao, CY ;
Fung, W ;
Guo, LJ .
IEEE JOURNAL OF SELECTED TOPICS IN QUANTUM ELECTRONICS, 2006, 12 (01) :134-142
[6]   Ultracompact biochemical sensor built with two-dimensional photonic crystal microcavity [J].
Chow, E ;
Grot, A ;
Mirkarimi, LW ;
Sigalas, M ;
Girolami, G .
OPTICS LETTERS, 2004, 29 (10) :1093-1095
[7]   Label-free optical resonant sensors for biochemical applications [J].
Ciminelli, Caterina ;
Campanella, Clarissa Martina ;
Dell'Olio, Francesco ;
Campanella, Carlo Edoardo ;
Armenise, Mario Nicola .
PROGRESS IN QUANTUM ELECTRONICS, 2013, 37 (02) :51-107
[8]   Silicon-on-Insulator microring resonator for sensitive and label-free biosensing [J].
De Vos, Katrien ;
Bartolozzi, Irene ;
Schacht, Etienne ;
Bienstman, Peter ;
Baets, Roel .
OPTICS EXPRESS, 2007, 15 (12) :7610-7615
[9]   Surface plasmon interferometer in silicon-on-insulator: novel concept for an integrated biosensor [J].
Debackere, Peter ;
Scheerlinck, Stijn ;
Bienstman, Peter ;
Baets, Roel .
OPTICS EXPRESS, 2006, 14 (16) :7063-7072
[10]   CMOS-compatible, athermal silicon ring modulators clad with titanium dioxide [J].
Djordjevic, Stevan S. ;
Shang, Kuanping ;
Guan, Binbin ;
Cheung, Stanley T. S. ;
Liao, Ling ;
Basak, Juthika ;
Liu, Hai-Feng ;
Yoo, S. J. B. .
OPTICS EXPRESS, 2013, 21 (12) :13958-13968