Clinical complications and quality assessments with computer-engineered complete dentures: A systematic review

被引:61
作者
Kattadiyil, Mathew T. [1 ]
AlHelal, Abdulaziz [2 ]
Goodacre, Brian J. [3 ]
机构
[1] Loma Linda Univ, Sch Dent, Adv Specialty Educ Program Prosthodont, Loma Linda, CA 92350 USA
[2] King Saud Univ, Dept Prosthet Dent Sci, Coll Dent, Riyadh, Saudi Arabia
[3] Loma Linda Univ, Sch Dent, Loma Linda, CA 92350 USA
关键词
FABRICATED COMPLETE DENTURES; CAD-CAM; SATISFACTION; RETENTION; BASE; ADAPTATION; EVOLUTION; TRIAL;
D O I
10.1016/j.prosdent.2016.12.006
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Statement of problem. Computer-engineered complete dentures (CECDs) have significant potential as shown by recent reports of outcomes and specific applications. An understanding of complications and quality assessment factors associated with CECDs from compiled data is lacking in published reports. Purpose. The purpose of this systematic review was to determine the clinical complications and quality assessments related to CECDs. Material and methods. Electronic searches of publications in English from January 1984 to September 2016 were performed in MEDLINE and Cochrane databases, with the results enriched by manual searches and citation mining to address 2 population intervention comparison outcome (PICO) questions: what are the clinical complications associated with CECDs, and what are the quality assessments with CECDs? Results. A review of 5 selected articles (limited data) on CECDs revealed patient dissatisfaction related to overall outcome (25.49%), inadequate retention (20.73%), and esthetic concerns (15.09%) as common complications. Quality assessment factors that were used to report complications were identified. Conclusions. Patient dissatisfaction, inadequate retention, and inadequate esthetics were the most common complications with CECDs. The addition of a trial placement option for CECDs could result in a better clinical outcome, reducing the incidence of other complications related to occlusal vertical dimension, centric relationship, tooth arrangement, and esthetics, improving patient satisfaction, and reducing remakes. The difficulty in reading the digital preview for an objective assessment before fabrication is a unique but not a common, complication for CECDs.
引用
收藏
页码:721 / 728
页数:8
相关论文
共 43 条
[1]  
AiHelal A, 2016, J PROSTHET DENT, V115, P531
[2]   The relationship between various parameters of complete denture quality and patients' satisfaction [J].
Alfadda, Sara A. .
JOURNAL OF THE AMERICAN DENTAL ASSOCIATION, 2014, 145 (09) :941-948
[3]   Comparison of retention between maxillary milled and conventional denture bases: A clinical study [J].
AlHelal, Abdulaziz ;
AlRumaih, Hamad S. ;
Kattadiyil, Mathew T. ;
Baba, Nadim Z. ;
Goodacre, Charles J. .
JOURNAL OF PROSTHETIC DENTISTRY, 2017, 117 (02) :233-238
[4]  
Bader James D, 2004, Tex Dent J, V121, P380
[5]   Prospective cohort pilot study of 2-visit CAD/CAM monolithic complete dentures and implant-retained overdentures: Clinical and patient-centered outcomes [J].
Bidra, Avinash S. ;
Farrell, Kimberly ;
Burnham, David ;
Dhingra, Ajay ;
Taylor, Thomas D. ;
Kuo, Chia-Ling .
JOURNAL OF PROSTHETIC DENTISTRY, 2016, 115 (05) :578-586
[6]   COMPUTER-AIDED TECHNOLOGY FOR FABRICATING COMPLETE DENTURES: SYSTEMATIC REVIEW OF HISTORICAL BACKGROUND, CURRENT STATUS, AND FUTURE PERSPECTIVES [J].
Bidra, Avinash S. ;
Taylor, Thomas D. ;
Agar, John R. .
JOURNAL OF PROSTHETIC DENTISTRY, 2013, 109 (06) :361-366
[7]  
Bilgin Mehmet Selim, 2016, Eur J Dent, V10, P286, DOI 10.4103/1305-7456.178304
[8]   Fabricating Complete Dentures with CAD/CAM and RP Technologies [J].
Bilgin, Mehmet Selim ;
Erdem, Ali ;
Aglarci, Osman Sami ;
Dilber, Erhan .
JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2015, 24 (07) :576-579
[9]  
Bilhan H, 2012, J ADV PROSTHODONT, V4, P109, DOI [10.4047/jap.2012.41.2.109, 10.4047/jap.2012.4.2.109]
[10]  
Busch M, 2006, Int J Comput Dent, V9, P113