Evaluation of differential phase contrast cone beam CT imaging system

被引:4
作者
Liu, Jiangkun [1 ]
Cai, Weixing [2 ]
Ning, Ruola [1 ,3 ]
机构
[1] Univ Rochester, Dept Elect & Comp Engn, 601 Elmwood Ave, Rochester, NY 14627 USA
[2] Univ Rochester, Dept Phys & Astron, Rochester, NY 14627 USA
[3] Univ Rochester, Med Ctr, Dept Imaging Sci, Rochester, NY 14642 USA
关键词
Cone beam CT; dark-field imaging; phase contrast imaging; COMPUTED-TOMOGRAPHY; INTERFEROMETER;
D O I
10.3233/XST-16184
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Grating-based differential phase contrast (DPC) imaging enables the use of a hospital-grade X-ray tube, but compromises the image quality due to insufficiently coherent illumination. In this research, a bench-top DPC cone beam CT (DPC-CBCT) was systematically evaluated and compared with the traditional attenuation-based CBCT in terms of contrast to noise ratio, noise property, and contrast resolution through phantom studies. In order to evaluate DPC-CBCT for soft tissue imaging, breast specimen and small animal studies were carried out. Phantom studies indicate that phase image has lower-frequency noise, higher CNR, and improved contrast resolution. However, phase image quality was degraded in soft tissue imaging due to coherence loss caused by small-angle scattering. Hence dark-field imaging was introduced to quantitatively investigate small-angle scattering caused by an object. Experimental results indicate that inhomogeneous objects affect phase contrast imaging, phase image is more sensitive to noise, and its performance is material dependent. Dark-field imaging could also be used to locate and reduce phase image noise and artifact caused by small-angle scattering.
引用
收藏
页码:357 / 372
页数:16
相关论文
共 22 条
[1]  
[Anonymous], 2001, ELEMENTS MODERN XRAY
[2]   Quantitative x-ray dark-field computed tomography [J].
Bech, M. ;
Bunk, O. ;
Donath, T. ;
Feidenhans'l, R. ;
David, C. ;
Pfeiffer, F. .
PHYSICS IN MEDICINE AND BIOLOGY, 2010, 55 (18) :5529-5539
[3]  
Bevins N., 2012, SPIE P
[4]  
Cai W., SPIE MED IMAGING
[5]  
Cai W., 2009, SPIE P
[6]  
Cai W., 2012, SPIE P
[7]   Investigation of Moire Pattern-based Phase Retrieval Approach for Differential Phase-contrast Cone Beam CT Imaging Using a Hospital-grade Tube [J].
Cai, Weixing ;
Ning, Ruola ;
Yu, Yang ;
Liu, Jiangkun ;
Conover, David .
MEDICAL IMAGING 2012: PHYSICS OF MEDICAL IMAGING, 2012, 8313
[8]   Diffraction enhanced x-ray imaging [J].
Chapman, D ;
Thomlinson, W ;
Johnston, RE ;
Washburn, D ;
Pisano, E ;
Gmur, N ;
Zhong, Z ;
Menk, R ;
Arfelli, F ;
Sayers, D .
PHYSICS IN MEDICINE AND BIOLOGY, 1997, 42 (11) :2015-2025
[9]   Differential x-ray phase contrast imaging using a shearing interferometer [J].
David, C ;
Nöhammer, B ;
Solak, HH ;
Ziegler, E .
APPLIED PHYSICS LETTERS, 2002, 81 (17) :3287-3289
[10]   High-resolution differential phase contrast imaging using a magnifying projection geometry with a microfocus x-ray source [J].
Engelhardt, Martin ;
Baumann, Joachim ;
Schuster, Manfred ;
Kottler, Christian ;
Pfeiffer, Franz ;
Bunk, Oliver ;
David, Christian .
APPLIED PHYSICS LETTERS, 2007, 90 (22)