Stabilization of the microtron-injector for a wide-band compact FIR FEL

被引:11
作者
Kazakevitch, GM
Jeong, YU
Pavlov, VM
Lee, BC
机构
[1] Korea Atom Energy Res Inst, Lab Quantum Opt, Taejon 305600, South Korea
[2] Russian Acad Sci, Budker Inst Nucl Phys, Novosibirsk 630090, Russia
关键词
microtron; magnetron; stabilization; frequency pulling; free electron laser; deviations;
D O I
10.1016/j.nima.2004.04.030
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
To provide parameters of a simple and inexpensive magnetron-driven microtron-injector acceptable for a wide-band FIR FEL, the microtron has been improved through stabilization of the beam current and the magnetron frequency. The beam current was stabilized during the macro-pulse by increasing the magnetron anode current. The pulse stabilization of the emission current makes possible the microtron operation with the maximal accelerated current, without risk of break-downs in the cavity and keeps the instability of the accelerated current at approximately 1% during long-time experiments. The magnetron frequency was stabilized using the microtron accelerating cavity as a stabilizing external resonator in a simple scheme that involved the cavity loading, of the magnetron through a ferrite insulator. The scheme provides stabilization of the magnetron frequency with a coefficient of 3.5. The stabilization of current and the frequency at the microtron FIR FEL-injector provides satisfactory intrapulse stability of the extracted lasing power of 40-50 W in the FIR macro-pulse having duration of 3-4 mus and a long-time pulse-to-pulse instability of the FIR pulse energy: in the range of less than or equal to 10%. Results of simulations of the stabilization based on the microtron operating parameters and measured results are presented and discussed. (C) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:115 / 119
页数:5
相关论文
共 5 条
[1]  
Kazakevitch G. M., 2001, PACS2001. Proceedings of the 2001 Particle Accelerator Conference (Cat. No.01CH37268), P2739, DOI 10.1109/PAC.2001.987891
[2]   Investigation of bunch repetition rate deviations in FIR FEL driven by a magnetron-based microtron [J].
Kazakevitch, GM ;
Jeong, YU ;
Lee, BC ;
Lee, JM .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2002, 483 (1-2) :331-335
[3]   Bunching properties of a classical microtron-injector for a far infrared free electron laser [J].
Kazakevitch, GM ;
Serednyakov, SS ;
Vinokurov, NA ;
Jeong, YU ;
Lee, BC ;
Lee, JM .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2001, 475 (1-3) :599-602
[4]  
LUGANSKY LB, 1965, HIGH POWER ELECT, P238
[5]  
ZAVOROTILO VN, 1977, ACCELERATORS, V16, P34