Qualitative and quantitative analysis of 2, 5-anhydro-D-mannitol in low molecular weight heparins with high performance anion exchange chromatography hyphenated quadrupole time of flight mass spectrometry

被引:5
|
作者
Yi, Lin [1 ,2 ]
Zhang, Qinghua [3 ]
Meng, Yao [1 ,2 ]
Hao, Jie [1 ,2 ]
Xie, Bingying [1 ,2 ]
Gan, Hao [3 ]
Li, Duxin [1 ,2 ]
Dong, Kai [3 ]
Zhang, Zhenqing [1 ,2 ]
机构
[1] Soochow Univ, Jiangsu Key Lab Translat Res & Therapy Neuropsych, Suzhou 215021, Jiangsu, Peoples R China
[2] Soochow Univ, Coll Pharmaceut Sci, Suzhou 215021, Jiangsu, Peoples R China
[3] Tianjin Chase Sun Pharmaceut Co LTD, Tianjin 300111, Peoples R China
基金
中国国家自然科学基金;
关键词
HPAEC-PAD-MS; Heparin; Low molecular weight heparin; Nadroparin; 2,5-Anhydro-manitol; Monosaccharide composition; HYDROPHILIC INTERACTION CHROMATOGRAPHY; LIQUID-CHROMATOGRAPHY; DISACCHARIDE ANALYSIS; STRUCTURAL FEATURES; SULFATE; ANTITHROMBIN; GLYCOSAMINOGLYCANS; OLIGOSACCHARIDES; DEPOLYMERIZATION; DEGRADATION;
D O I
10.1016/j.chroma.2018.07.058
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Low molecular weight heparins (LMWHs), derived from unfractionated heparin (UFH) by chemical or enzymatic degradation, have lower side effects than that of heparin. Enoxaparin, nadroparin, and dal-teparin are the most widely used LMWHs. Nadroparin and dalteparin are prepared through nitrous acid degradation followed by a subsequent reduction process, in which specific residue, 2,5-anhydron-D-mannitol (An-Man), is formed at the reducing terminals of generated sugar chains. However, few practicable analytical method was available to analyze An-Man qualitatively and quantitatively. In this work, a HPAEC-PAD-MS method was developed to analyze monosaccharides in heparin and LMWHs, especially An-Man. An ion suppressor is set up between HPAEC and MS to remove the nonvolatile salts from HPAEC and make the elute compatible to MS. Various monosaccharides were separated well with HPAEC. Online MS and MS/MS confirmed all sugar residues in the hydrolysates of heparin samples. The specific residue, An-Man, was only observed in the hydrolysates of LMWHs prepared with nitrous acid degradation and reduction. In addition, major glucosamine and minor arabinose/galactose were observed in all heparin samples. The amounts of these sugar residues were quantitated with PAD, simultaneously. The ratio of glucosamine to An-Man could be used to calculate the molecular weight of LMWHs. The calculated values are comparable to the value measured with size-exclusion chromatography-multiple angle laser scattering detection. Higher the ratio of glucosamine to An-Man higher the molecular weight. The HPAEC-PAD-MS platform is an accurate, precise and efficient way to identify LMWHs by determination of An-Man. It is also an alternative method to detect the MWs of LMWHs having An-Man for quality control purposes. (C) 2018 Elsevier B.V. All rights reserved.
引用
收藏
页码:160 / 167
页数:8
相关论文
共 11 条
  • [1] Qualitative analysis of enzymatic and chemical depolymerized low molecular weight heparins by UHPLC coupled with electrospray ionization quadrupole time-of-flight-mass spectrometry
    Sadowski, Radoslaw
    Gadzala-Kopciuch, Renata
    Buszewski, Boguslaw
    JOURNAL OF SEPARATION SCIENCE, 2020, 43 (15) : 3036 - 3044
  • [2] Profiling Analysis of Low Molecular Weight Heparins by Multiple Heart-Cutting Two Dimensional Chromatography with Quadruple Time-of-Flight Mass Spectrometry
    Ouyang, Yilan
    Zeng, Yangyang
    Rong, Yinxiu
    Song, Yue
    Shi, Lv
    Chen, Bo
    Yang, Xinlei
    Xu, Naiyu
    Linhardt, Robert J.
    Zhang, Zhenqing
    ANALYTICAL CHEMISTRY, 2015, 87 (17) : 8957 - 8963
  • [3] Structural Analysis of Low Molecular Weight Heparin by Ultraperformance Size Exclusion Chromatography/Time of Flight Mass Spectrometry and Capillary Zone Electrophoresis
    Zhang, Qianqian
    Chen, Xi
    Zhu, Zhijia
    Zhan, Xueqiang
    Wu, Yanfang
    Song, Lankun
    Kang, Jingwu
    ANALYTICAL CHEMISTRY, 2013, 85 (03) : 1819 - 1827
  • [4] Reversed-phase ion-pair ultra-high-performance-liquid chromatography-mass spectrometry for fingerprinting low-molecular-weight heparins
    Langeslay, Derek J.
    Urso, Elena
    Gardini, Cristina
    Naggi, Annamaria
    Torri, Giangiacomo
    Larive, Cynthia K.
    JOURNAL OF CHROMATOGRAPHY A, 2013, 1292 : 201 - 210
  • [5] Qualitative and quantitative analysis of heparin and low molecular weight heparins using size exclusion chromatography with multiple angle laser scattering/refractive index and inductively coupled plama/mass spectrometry detectors
    Ouyang, Yilan
    Zeng, Yangyang
    Yi, Lin
    Tang, Hong
    Li, Duxin
    Linhardt, Robert J.
    Zhang, Zhenqing
    JOURNAL OF CHROMATOGRAPHY A, 2017, 1522 : 56 - 61
  • [6] Identification of low molecular weight organic acids by ion chromatography/hybrid quadrupole time-of-flight mass spectrometry during Uniblu-A ozonation
    Amorisco, Apollonia
    Locaputo, Vito
    Pastore, Carlo
    Mascolo, Giuseppe
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2013, 27 (01) : 187 - 199
  • [7] Ultra high performance liquid chromatography-time-of-flight high resolution mass spectrometry in the analysis of hexabromocyclododecane diastereomers: Method development and comparative evaluation versus ultra high performance liquid chromatography coupled to Orbitrap high resolution mass spectrometry and triple quadrupole tandem mass spectrometry
    Zacs, D.
    Rjabova, J.
    Pugajeva, I.
    Nakurte, I.
    Viksna, A.
    Bartkevics, V.
    JOURNAL OF CHROMATOGRAPHY A, 2014, 1366 : 73 - 83
  • [8] Development of a high-throughput method for the comprehensive lipid analysis in milk using ultra-high performance supercritical fluid chromatography combined with quadrupole time-of-flight mass spectrometry
    Tang, Yan
    Ali, Muhammad Mujahid
    Sun, Xuechun
    Debrah, Augustine Atta
    Wang, Mengyu
    Hou, Haiyue
    Guo, Qiaozhen
    Du, Zhenxia
    JOURNAL OF CHROMATOGRAPHY A, 2021, 1658
  • [9] Combined use of liquid chromatography-hybrid quadrupole time-of-flight mass spectrometry (LC-QTOF-MS) and high performance liquid chromatography with photodiode array detector (HPLC-DAD) in systematic toxicological analysis
    Broecker, Sebastian
    Pragst, Fritz
    Bakdash, Abdulsallam
    Herre, Sieglinde
    Tsokos, Michael
    FORENSIC SCIENCE INTERNATIONAL, 2011, 212 (1-3) : 215 - 226
  • [10] Ultra-high-performance supercritical fluid chromatography with quadrupole-time-of-flight mass spectrometry (UHPSFC/QTOF-MS) for analysis of lignin-derived monomeric compounds in processed lignin samples
    Prothmann, Jens
    Sun, Mingzhe
    Spegel, Peter
    Sandahl, Margareta
    Turner, Charlotta
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2017, 409 (30) : 7049 - 7061