Gas Chromatography-Mass Spectrometry of Ethyl Palmitate Calibration and Resolution with Ethyl Oleate as Biomarker Ethanol Sub Acute in Urine Application Study

被引:1
|
作者
Suaniti, Ni Made [1 ]
Manurung, Manuntun [2 ]
机构
[1] Udayana Univ, Analyt & Forens Chem Lab, Dept Chem, Fac Math & Sci, Badung 80361, Bali, Indonesia
[2] Udayana Univ, Phys Chem Lab, Dept Chem, Fac Math & Sci, Badung 80361, Bali, Indonesia
来源
5TH INTERNATIONAL CONFERENCE AND WORKSHOP ON BASIC AND APPLIED SCIENCES (ICOWOBAS 2015) | 2016年 / 1718卷
关键词
GC-MS; Palmitate; Oleate; Ethanol; biomarker; Resolution;
D O I
10.1063/1.4943335
中图分类号
O59 [应用物理学];
学科分类号
摘要
Gas Chromatography-Mass Spectrometry is used to separate two and more compounds and identify fragment ion specific of biomarker ethanol such as palmitic acid ethyl ester (PAPE), as one of the fatty acid ethyl esters as early detection through conyugated reaction. This study aims to calibrate ethyl palmitate and develop analysis with oleate acid. This methode can be used analysis ethanol and its chemistry biomarker in ethanol sub-acute consumption as analytical forensic toxicology. The result show that ethanol level in urine rats Wistar were 9.21 and decreased 6.59 ppm after 48 hours consumption. Calibration curve of ethyl palmitate was y = 0.2035 x + 1.0465 and R2 = 0.9886. Resolution between ethyl palmitate and oleate were >1.5 as good separation with fragment ion specific was 88 and the retention time was 18 minutes.
引用
收藏
页数:6
相关论文
共 34 条
  • [21] Recent trends in application of multivariate curve resolution approaches for improving gas chromatography-mass spectrometry analysis of essential oils
    Jalali-Heravi, Mehdi
    Parastar, Hadi
    TALANTA, 2011, 85 (02) : 835 - 849
  • [22] Development and validation of an automated static headspace gas chromatography-mass spectrometry (SHS-GC-MS) method for monitoring the formation of ethyl methane sulfonate from ethanol and methane sulfonic acid
    Jacq, Karine
    Delaney, Ed
    Teasdale, Andrew
    Eyley, Steve
    Taylor-Worth, Karen
    Lipczynski, Andrew
    Reif, Van D.
    Elder, David P.
    Facchine, Kevin L.
    Golec, Simon
    Oestrich, Rolf Schulte
    Sandra, Pat
    David, Frank
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2008, 48 (05) : 1339 - 1344
  • [23] Development and validation of a gas chromatography-mass Spectrometry method for the determination of Phenazopyridine in rat plasma: Application to the pharmacokinetic study
    Chen, Qinhua
    Li, Kaijun
    Zhang, Zhuo
    Li, Peng
    Liu, Jia
    Li, Qiang
    BIOPHARMACEUTICS & DRUG DISPOSITION, 2007, 28 (08) : 439 - 444
  • [24] Metabolomic study of mouse embryonic fibroblast cells in response to autophagy based on high resolution gas chromatography-mass spectrometry
    Shen, Sensen
    Li, Linnan
    Song, Shiyao
    Bai, Yu
    Liu, Huwei
    INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2018, 434 : 215 - 221
  • [25] Application of ethyl chloroformate derivatization for solid-phase microextraction-gas chromatography-mass spectrometric determination of bisphenol-A in water and milk samples
    Mudiam, Mohana Krishna Reddy
    Jain, Rajeev
    Dua, Virendra K.
    Singh, Amit Kumar
    Sharma, V. P.
    Murthy, R. C.
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2011, 401 (05) : 1695 - 1701
  • [26] Application of Pyrolysis-Gas Chromatography-Mass Spectrometry and Multivariate Analysis to Study Bacteria and Fungi in Biofilms Used for Bioremediation
    Melucci, Dora
    Fedi, Stefano
    Locatelli, Marcello
    Locatelli, Clinio
    Montalbani, Simona
    Cappelletti, Martina
    CURRENT DRUG TARGETS, 2013, 14 (09) : 1023 - 1033
  • [27] Exploratory study on noninvasive biomarker of silicosis in exhaled breath by solid-phase microextraction-gas chromatography-mass spectrometry analysis
    Yi, Zonghui
    Dong, Simin
    Wang, Xixi
    Xu, Mucen
    Li, Yongxin
    Xie, Linshen
    INTERNATIONAL ARCHIVES OF OCCUPATIONAL AND ENVIRONMENTAL HEALTH, 2023, 96 (06) : 857 - 868
  • [28] SIMULTANEOUS GAS-CHROMATOGRAPHY MASS-SPECTROMETRY ASSAY OF METHADONE AND 2-ETHYL-1, 5-DIMETHYL-3,3-DIPHENYLPYRROLIDINE (EDDP) IN URINE
    BAUGH, LD
    LIU, RH
    WALIA, AS
    JOURNAL OF FORENSIC SCIENCES, 1991, 36 (02) : 548 - 555
  • [29] Application of the Bland-Altman and Receiver Operating Characteristic (ROC) Approaches to Study Isotope Effects in Gas Chromatography-Mass Spectrometry Analysis of Human Plasma, Serum and Urine Samples
    Tsikas, Dimitrios
    MOLECULES, 2024, 29 (02):
  • [30] A comparison of high- and low-resolution gas chromatography-mass spectrometry for herbal product classification: A case study with Ocimum essential oils
    Abraham, Evelyn J.
    Wallace, E. Diane
    Kellogg, Joshua J.
    PHYTOCHEMICAL ANALYSIS, 2023, 34 (06) : 680 - 691