Failure of a precast RC building due to Emilia-Romagna earthquakes

被引:46
作者
Ercolino, M. [1 ]
Magliulo, G. [2 ]
Manfredi, G. [2 ]
机构
[1] Univ Greenwich, Dept Engn Sci, Cent Ave, Chatham ME4 4TB, Kent, England
[2] Univ Naples Federico II, Dept Struct Engn & Architecture, Via Claudio 21, I-80125 Naples, Italy
关键词
Precast structure; Earthquake-induced collapse; Friction connection; Nonlinear dynamic analysis; INDUSTRIAL BUILDINGS; SEISMIC PERFORMANCE; CONNECTIONS; STRENGTH; DAMAGE;
D O I
10.1016/j.engstruct.2016.03.054
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Two 5.9 M-w and 5.8 M-w earthquakes hit Emilia-Romagna region on May 2012. Most of the precast RC one-story structures exhibited significant damage, causing huge economic losses as well as deaths. These events produced in-situ observations and data to develop a deeper knowledge on the seismic behavior and collapse of this structural typology. This paper deals with the seismic assessment of a real precast RC industrial building with friction connections. The structure is located in Emilia-Romagna region and it was severely damaged during the second seismic event on May 29th. Structural columns exhibited cracking and yielding at the base as well as significant rotations along one direction. Moreover, relative displacements were recorded in both beam-to-column connections and roof-to-beam connections and several loss of support phenomena occurred for the roof elements. A detailed nonlinear structural model is defined in OpenSees code and nonlinear dynamic analyses are performed with the recorded accelerations time-histories of the two seismic events. By comparing the numerical results with the actual response of the structure, the adopted model is validated and the main damage typologies are also justified. (C) 2016 Elsevier Ltd. All rights reserved.
引用
收藏
页码:262 / 273
页数:12
相关论文
共 28 条
  • [1] Effects of May 2012 Emilia earthquake on industrial buildings of early '900 on the Po river line
    Artioli, E.
    Battaglia, R.
    Tralli, A.
    [J]. ENGINEERING STRUCTURES, 2013, 56 : 1220 - 1233
  • [2] Belleri A, 2014, J PERFORM CONSTR FAC
  • [3] Vulnerability assessment and retrofit solutions of precast industrial structures
    Belleri, Andrea
    Torquati, Mauro
    Riva, Paolo
    Nascimbene, Roberto
    [J]. EARTHQUAKES AND STRUCTURES, 2015, 8 (03) : 801 - 820
  • [4] Seismic performance of ductile connections between precast beams and roof elements
    Belleri, Andrea
    Torquati, Mauro
    Riva, Paolo
    [J]. MAGAZINE OF CONCRETE RESEARCH, 2014, 66 (11) : 553 - 562
  • [5] Role of wall panel connections on the seismic performance of precast structures
    Biondini, Fabio
    Dal Lago, Bruno
    Toniolo, Giandomenico
    [J]. BULLETIN OF EARTHQUAKE ENGINEERING, 2013, 11 (04) : 1061 - 1081
  • [6] Carydis P, 2012, ING SISMICA-ITAL, P2
  • [7] Seismic fragility of Italian RC precast industrial structures
    Casotto, C.
    Silva, V.
    Crowley, H.
    Nascimbene, R.
    Pinho, R.
    [J]. ENGINEERING STRUCTURES, 2015, 94 : 122 - 136
  • [8] CEN, 2005, EN 1998-1
  • [9] European Committee for Standardization (CEN), 2005, 199832005 CEN
  • [10] Faggiano B., 2009, PROGETTAZIONE SISMIC, V3, P203