Thermal modeling and experimental research of a gas engine-driven heat pump in variable condition

被引:22
作者
Hu, Bin [1 ,2 ]
Li, Cuichao [3 ]
Yin, Xiang [1 ]
Cao, Feng [1 ]
Shu, Pengcheng [1 ]
机构
[1] Xi An Jiao Tong Univ, Sch Energy & Power Engn, 28 Xianning West Rd, Xian 710049, Shaanxi, Peoples R China
[2] Shanghai Jiao Tong Univ, Inst Refrigerat & Cryogen, Shanghai 200240, Peoples R China
[3] Shanghai Jiao Tong Univ, Engn Training Ctr, Shanghai 200240, Peoples R China
基金
中国国家自然科学基金;
关键词
Gas engine-driven heat pump; PER; Variable condition; Engine speed; Waste heat recovery; PERFORMANCE; EFFICIENT;
D O I
10.1016/j.applthermaleng.2017.05.189
中图分类号
O414.1 [热力学];
学科分类号
摘要
In order to analyze the influence of various factors on the system performance of the gas engine-driven heat pump system with waste heat recovery, theoretical model of a gas engine-driven heat pump is conducted in this paper. The thermal modeling of the gas engine-driven heat pump including both the heat pump and the gas engine system was performed and the system performances under different operating parameters were simulated. The results show that the engine speed and the outdoor air temperature affected the system performance significantly. With the engine speed increasing from 1400 rpm to 2000 rpm, the heating capacity increased by 26.9% while system primary energy ratio (PER) decreased by 17.6% for the air temperature of 10 degrees C. When the outdoor air temperature reduced from 10 to 2 degrees C, the heat capacity reduced by 14.6% but the system PER decreased by 11.8% with the engine speed of 1800 rpm. The water inlet temperature act insignificantly on heating capacity, while it had some influence on the system PER. With the water inlet temperature increasing from 38 to 44 degrees C, the system PER decreased by 5.7% and 4.4% for the outdoor air temperature of 10 and 2 degrees C, respectively. The experimental test is also carried out to validate the simulation models. The comparison of modeling results and the experimental measured values for various amounts of the heating capacity, PER, waste heat recovery and the percentage of heat recovery showed 4.8%, 4.6%, 6.7% and 5.6% average difference percentage, which indicated an accepted agreement. From the perspective of energy savings, the gas engine-driven heat pump should be operated with engine speed as low as possible in the case of meeting the heating requirements. (C) 2017 Published by Elsevier Ltd.
引用
收藏
页码:1504 / 1513
页数:10
相关论文
共 26 条
[1]   Simplified steady-state modelling of a single stage vapour compression plant. Model development and validation [J].
Cabello, R ;
Navarro, J ;
Torrella, E .
APPLIED THERMAL ENGINEERING, 2005, 25 (11-12) :1740-1752
[2]   Capacity modulation of an inverter-driven multi-air conditioner using electronic expansion valves [J].
Choi, JM ;
Kim, YC .
ENERGY, 2003, 28 (02) :141-155
[3]  
Ferguson C.R., 1986, INTERNAL COMBUSTION
[4]   Innovations in energy efficient and environmentally friendly space-conditioning systems [J].
Garimella, S .
ENERGY, 2003, 28 (15) :1593-1614
[5]   A review of gas engine driven heat pumps (GEHPs) for residential and industrial applications [J].
Hepbasli, Arif ;
Erbay, Zafer ;
Icier, Filiz ;
Colak, Neslihan ;
Hancioglu, Ebru .
RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2009, 13 (01) :85-99
[6]   District heating and gas engine heat pump: Economic analysis based on a case study [J].
Lazzarin, R ;
Noro, M .
APPLIED THERMAL ENGINEERING, 2006, 26 (2-3) :193-199
[7]   A novel parallel-type hybrid-power gas engine-driven heat pump system [J].
Li, Ying-Lin ;
Zhang, Xiao-Song ;
Cai, Liang .
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2007, 30 (07) :1134-1142
[8]  
Lian Z., 2015, INT J REFRIG, V28, P4697
[9]   Experimental study of turbulent flow heat transfer and pressure drop in a plate heat exchanger with chevron plates [J].
Muley, A ;
Manglik, RM .
JOURNAL OF HEAT TRANSFER-TRANSACTIONS OF THE ASME, 1999, 121 (01) :110-117
[10]  
Ratel J, 1998, ASHRAE J, V40, P65