Round Window Membrane Motion Induced by Bone Conduction Stimulation at Different Excitation Sites: Methodology of Measurement and Data Analysis in Cadaver Study

被引:4
作者
Kwacz, Monika [1 ]
Niemczyk, Kazimierz [2 ]
Wysocki, Jaroslaw [3 ]
Lachowska, Magdalena [2 ]
Borkowski, Pawel [4 ]
Malkowska, Maria [5 ]
Sokolowski, Jacek [2 ]
机构
[1] Warsaw Univ Technol, Inst Micromech & Photon, Warsaw, Poland
[2] Med Univ Warsaw, Dept Otolaryngol, Ul Banacha 1a, PL-02097 Warsaw, Poland
[3] Lazarski Univ, Med Fac, Warsaw, Poland
[4] Warsaw Univ Technol, Inst Aeronaut & Appl Mech, Warsaw, Poland
[5] Vistula Univ, Warsaw Sch Tourism & Hospitality Management, Warsaw, Poland
关键词
Air conduction; Bone conduction; Cochlea; Implant; Inner ear; Round window; Vibration pattern; Volume displacement; ANCHORED HEARING-AID; SOUND; TRANSMISSION; BAHA; COMPLICATIONS; RESPONSES; IMPLANTS; VALIDITY; SYSTEM;
D O I
10.1097/AUD.0000000000000725
中图分类号
R36 [病理学]; R76 [耳鼻咽喉科学];
学科分类号
100104 ; 100213 ;
摘要
Objectives: The aim of this study was to investigate the following: (1) the vibration pattern of the round window (RW) membrane in human cadavers during air (AC) and bone conduction (BC) stimulation at different excitation sites; (2) the effect of the stimulation on the fluid volume displacement (VD) at the RW and compare the VD between BC and AC stimulation procedures; (3) the effectiveness of cochlear stimulation by the bone implant at different excitation sites. Design: The RW membrane vibrations were measured by using a commercial scanning laser Doppler vibrometer. The RW vibration amplitude was recorded at 69 measurement points evenly distributed in the measurement field covering the entire surface of the RW membrane and a part of the surrounding bony surface. RW vibration was induced first with AC and then with BC stimulation through an implant positioned at two sites. The first site was on the skull surface at the squamous part of the temporal bone (implant no. 1), a place typical for bone-anchored hearing aids. The second site was close to the cochlea at the bone forming the ampulla of the lateral semicircular canal (implant no. 2). The displacement amplitude (d(P)) of the point P on the promontory was determined and used to calculate the relative displacement (dr(RW)) of points on the RW membrane, dr(RW) = d(RW) - d(P). VD parameter was used to analyze the effectiveness of cochlear stimulation by the bone implant screwed at different excitation sites. Results: RW membrane displacement amplitude of the central part of the RW was similar for AC and BC implant no. 1 stimulation, and for BC implant no. 2 much larger for frequency range >1kHz. BC implant no. 2 causes a larger displacement amplitude of peripheral parts of the RW and the promontory than AC and BC implant no. 1, and BC implant no. 1 causes larger than AC stimulation. The effect of BC stimulation exceeds that of AC with identical intensity, and that the closer BC stimulation to the otic capsule, the more effective this stimulation is. A significant decrease in the value of VD at the RW is observed for frequencies >2kHz for both AC and BC stimulation with BC at both locations of the titanium implant placement. For frequencies >1kHz, BC implant no. 2 leads to a significantly larger VD at the RW compared to BC implant no. 1. Thus, the closer to the otic capsule the BC stimulation is located, the more effective it is. Conclusions: Experimental conditions allow for an effective acoustic stimulation of the inner ear by an implant screwed to the osseous otic capsule. The mechanical effect of BC stimulation with a titanium implant placed in the bone of the ampulla of the lateral semicircular canal significantly exceeds the effect of an identical stimulation with an implant placed in the temporal squama at a conventional site for an implant anchored in the bone. The developed research method requires the implementation on a larger number of temporal bones in order to obtain data concerning interindividual variability of the observed mechanical phenomena.
引用
收藏
页码:1437 / 1444
页数:8
相关论文
共 43 条
  • [1] [Anonymous], 2016, ISO 389-3
  • [2] Revision BAHA surgery
    Battista, Robert A.
    Littlefield, Philip D.
    [J]. OTOLARYNGOLOGIC CLINICS OF NORTH AMERICA, 2006, 39 (04) : 801 - +
  • [3] VALIDITY OF BONE CONDUCTION STIMULATED ABR, MLR AND OTOACOUSTIC EMISSIONS
    COLLET, L
    CHANAL, JM
    HELLAL, H
    GARTNER, M
    MORGON, A
    [J]. SCANDINAVIAN AUDIOLOGY, 1989, 18 (01): : 43 - 46
  • [5] Magnitude and phase of three-dimensional (3D) velocity vector: Application to measurement of cochlear promontory motion during bone conduction sound transmission
    Dobrev, Ivo
    Sim, Jae Hoon
    [J]. HEARING RESEARCH, 2018, 364 : 96 - 103
  • [6] Sound wave propagation on the human skull surface with bone conduction stimulation
    Dobrev, Ivo
    Sim, Jae Hoon
    Stenfelt, Stefan
    Ihrle, Sebastian
    Gerig, Rahel
    Pfiffner, Flurin
    Eiber, Albrecht
    Huber, Alexander M.
    Roosli, Christof
    [J]. HEARING RESEARCH, 2017, 355 : 1 - 13
  • [7] Transmission of bone conducted sound - Correlation between hearing perception and cochlear vibration
    Eeg-Olofsson, Mans
    Stenfelt, Stefan
    Taghavi, Hamidreza
    Reinfeldt, Sabine
    Hakansson, Bo
    Tengstrand, Tomas
    Finizia, Caterina
    [J]. HEARING RESEARCH, 2013, 306 : 11 - 20
  • [8] Implications for Contralateral Bone-Conducted Transmission as Measured by Cochlear Vibrations
    Eeg-Olofsson, Mans
    Stenfelt, Stefan
    Granstrom, Gosta
    [J]. OTOLOGY & NEUROTOLOGY, 2011, 32 (02) : 192 - 198
  • [9] Transmission of bone-conducted sound in the human skull measured by cochlear vibrations
    Eeg-Olofsson, Mans
    Stenfelt, Stefan
    Tjellstrom, Anders
    Granstrom, Gosta
    [J]. INTERNATIONAL JOURNAL OF AUDIOLOGY, 2008, 47 (12) : 761 - 769
  • [10] THE BONE-ANCHORED HEARING-AID - PRINCIPAL DESIGN AND A PSYCHOACOUSTICAL EVALUATION
    HAKANSSON, B
    TJELLSTROM, A
    ROSENHALL, U
    CARLSSON, P
    [J]. ACTA OTO-LARYNGOLOGICA, 1985, 100 (3-4) : 229 - 239