Ion mobility measurements in Ar-CO2, Ne-CO2, and Ne-CO2-N2 mixtures, and the effect of water contents

被引:12
作者
Deisting, Alexander [1 ,2 ]
Garabatos, Chilo [1 ]
Szabo, Alexander [3 ]
机构
[1] GSI Helmholtzzentrum Schwerionenforsch GmbH, Planckstr 1, Darmstadt, Germany
[2] Heidelberg Univ, Phys Inst, Heidelberg, Germany
[3] Comenius Univ, Fac Math Phys & Informat, Bratislava, Slovakia
关键词
Ion mobility; Gaseous detectors; ALICE time projection chamber; TRANSPORT-PROPERTIES; GASEOUS-IONS; GEM;
D O I
10.1016/j.nima.2018.07.008
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
A detector has been constructed for measuring ion mobilities of gas mixtures at atmospheric pressure and room temperature. The detector consists of a standard triple GEM amplification region and a drift region where ions drift. A method has been developed to measure the ions' arrival time at a cathode wire-grid by differentiating the recorded signals on this electrode. Simulations prove that this method is accurate and robust. The ion mobility in different gas mixtures is measured while applying different drift field values ranging from 200 V cm(-1) to 1100 Vcm(-1). From an extrapolation of a Blanc's law fit to measurements in Ar-CO2 mixtures we find the reduced mobility of the drifting (cluster) ion species in pure argon to be 1.94 +/- 0.01 cm(2) V-1 s(-1) and in pure carbondioxide to be 1.10 +/- 0.01 cm(2) V-1 s(-1). Applying the same procedure to our measurements in Ne-CO2 yields 4.06 +/- 0.07 cm(2) V-1 s(-1) and 1.09 +/- 0.01 cm(2) V-1 s(-1) for the reduced mobilities in pure neon and carbon-dioxide, respectively. Admixtures of N-2 to Ne-CO2 (90-10) reduce somewhat the mobility. For the baseline gas mixture of the future ALICE Time Projection Chamber, Ne-CO2-N-2 (90-10-5), the measured reduced mobility of the drifting ions is 2.92 +/- 0.04 cm(2) V-1 s(-1). Ion mobilities are examined for different water content ranging from 70 ppm to about 2000 ppm in the gas using Ar-CO2 (90-10) and Ne-CO2 (90-10). A slight decrease of ion mobility is observed for the addition of several hundred ppm of water.
引用
收藏
页码:1 / 8
页数:8
相关论文
共 31 条
[1]   The ALICE TPC, a large 3-dimensional tracking device with fast readout for ultra-high multiplicity events [J].
Alme, J. ;
Andres, Y. ;
Appelshaeuser, H. ;
Bablok, S. ;
Bialas, N. ;
Bolgen, R. ;
Bonnes, U. ;
Bramm, R. ;
Braun-Munzinger, P. ;
Campagnolo, R. ;
Christiansen, P. ;
Dobrin, A. ;
Engster, C. ;
Fehlker, D. ;
Foka, Y. ;
Frankenfeld, U. ;
Gaardhoje, J. J. ;
Garabatos, C. ;
Glaessel, P. ;
Gutierrez, C. Gonzalez ;
Gros, P. ;
Gustafsson, H-A ;
Helstrup, H. ;
Hoch, M. ;
Ivanov, M. ;
Janik, R. ;
Junique, A. ;
Kalweit, A. ;
Keidel, R. ;
Kniege, S. ;
Kowalski, M. ;
Larsen, D. T. ;
Lesenechal, Y. ;
Lenoir, P. ;
Lindegaard, N. ;
Lippmann, C. ;
Mager, M. ;
Mast, M. ;
Matyja, A. ;
Munkejord, M. ;
Musa, L. ;
Nielsen, B. S. ;
Nikolic, V. ;
Oeschler, H. ;
Olsen, E. K. ;
Oskarsson, A. ;
Osterman, L. ;
Pikna, M. ;
Rehman, A. ;
Renault, G. .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2010, 622 (01) :316-367
[2]  
Appelsauser H., 2017, SPACE CHARGE DISTORT
[3]  
Blanc M. A., 1908, J PHYS, V7, P825
[4]  
Blum W., 2008, PARTICLE DETECTION D
[5]   Simulation of space-charge effects in an ungated GEM-based TPC [J].
Boehmer, F. V. ;
Ball, M. ;
Dorheim, S. ;
Hoeppner, C. ;
Ketzer, B. ;
Konorov, I. ;
Neubert, S. ;
Paul, S. ;
Rauch, J. ;
Vandenbroucke, M. .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2013, 719 :101-108
[6]  
CAEN, 1999, MOD N471 2 FOLD H V
[7]  
CAEN, 2002, MOD N 470 4 CHANN PR
[8]   POSITIVE-ION MOBILITIES IN CARBON-DIOXIDE [J].
COXON, PA ;
MORUZZI, JL .
JOURNAL DE PHYSIQUE, 1979, 40 :117-118
[9]   Measurements of ion mobility in argon and neon based gas mixtures [J].
Deisting, Alexander ;
Garabatos, Chilo ;
Szabo, Alexander ;
Vranic, Danilo .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2017, 845 :215-217
[10]  
Edgetech Instruments, DEWMASTER CHILL MIRR