Wind-induced responses and equivalent static design method of oval-shaped arch-supported membrane structure

被引:17
作者
Kandel, Arjun [1 ,3 ]
Sun, Xiaoying [1 ,2 ]
Wu, Yue [1 ,2 ]
机构
[1] Harbin Inst Technol, Minist Educ, Key Lab Struct Dynam Behav & Control, Harbin 150090, Peoples R China
[2] Harbin Inst Technol, Minist Ind & Informat Technol, Key Lab Smart Prevent & Mitigat Civil Engn Disast, Harbin 150090, Peoples R China
[3] Natl Coll Engn, Dept Civil Engn, Lalitpur, Nepal
基金
中国国家自然科学基金;
关键词
Arch-supported membrane structure; Wind tunnel test; Wind-induced response; Gust loading factor; Nonlinear adjustment factor; LOADS; COMPUTATION; SIMULATION; ROOFS;
D O I
10.1016/j.jweia.2021.104620
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This paper presents the wind-induced responses and wind resistant design method of arch-supported membrane structure. Series of rigid model wind tunnel tests are carried out to record wind pressure data on the roof surface of experimental models. Random vibration time history analysis is employed to get wind-induced responses. Geometric nonlinearity is taken into account in dynamic analysis. Effects of different factors such as wind velocity, wind direction, arch span, rise-span ratio, and membrane prestress on peak wind-induced responses are presented meticulously. Displacement, membrane stress, internal force of cable and abutment reaction are analyzed to study the peak responses of structure. This study considers the influence of boundary wall by conducting wind tunnel tests on both enclosed and open models. Results show that peak responses increase significantly as wind velocity and/or arch span increase. The performance of membrane structures can be enhanced by increasing membrane prestress, but the effect is quite small. Similarly, responses increase with rise-span ratio, but the rate of increment is not constant. Effect of the boundary wall depends significantly on wind direction and rise-span ratio. Additionally, this paper proposes the concept of equivalent static design method based on gust loading factor and nonlinear adjustment factor.
引用
收藏
页数:18
相关论文
共 40 条
  • [1] American Society of Civil Engineers, 1999, MANUAL PRACTICE WIND, DOI [10.1061/9780784403198, DOI 10.1061/9780784403198]
  • [2] American Society of Civil Engineers (ASCE), 2011, MIN DES LOADS ASS CR
  • [3] [Anonymous], 2014, JGJ/T 338-2014
  • [4] [Anonymous], 1999, INT J SPACE STRUCTUR
  • [5] [Anonymous], 2004, RLB Recommendations for Loads on Buildings
  • [6] Australian Wind Engineering Society, 2019, WIND ENG STUD BUILD
  • [7] Booton RC., 1954, IRE T CIRCUIT THEORY, V1, P9, DOI [10.1109/TCT.1954.6373354, DOI 10.1109/TCT.1954.6373354]
  • [8] Building Center of Japan (BCJ), 2008, WIND TUNN EXP GUID
  • [9] EQUIVALENT LINEARIZATION TECHNIQUES
    CAUGHEY, TK
    [J]. JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1962, 34 (12) : 2001 - &
  • [10] CECS (China Association for Engineering Construction Standardization), 2015, 1582015 CECS