Rapid identification of the bacterial pathogens responsible for urinary tract infections using direct injection CE

被引:86
作者
Armstrong, DW [1 ]
Schneiderheinze, JM [1 ]
机构
[1] Univ Missouri, Dept Chem, Rolla, MO 65409 USA
关键词
D O I
10.1021/ac000302j
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The use of high-performance capillary electrokinetic techniques for the separation, identification, and quantitation of intact microbes represents a new frontier for separation science. In this work, if is demonstrated that pathogens most responsible for urinary tract infections can be distinguished from one another after direct injection of untreated urine. High efficiencies (often exceeding 1 000 000 plates/m) and short analysis times (<10 min) are characteristics of this approach. The concentration of the urine matrix appears to be able to cause a small, but definite, change in the electroosmotic now velocity. This high-efficiency separation-based approach could prove to be invaluable for the diagnosis and tracking of certain diseases. It also could form the basis for a variety of rapid microbial assays.
引用
收藏
页码:4474 / 4476
页数:3
相关论文
共 25 条
  • [1] Separating microbes in the manner of molecules. 1. Capillary electrokinetic approaches
    Armstrong, DW
    Schulte, G
    Schneiderheinze, JM
    Westenberg, DJ
    [J]. ANALYTICAL CHEMISTRY, 1999, 71 (24) : 5465 - 5469
  • [2] Infectious disease - PCR detection of bacteria in seven minutes
    Belgrader, P
    Benett, W
    Hadley, D
    Richards, J
    Stratton, P
    Mariella, R
    Milanovich, F
    [J]. SCIENCE, 1999, 284 (5413) : 449 - 450
  • [3] Lectin-based affinity capture for MALDI-MS analysis of bacteria
    Bundy, J
    Fenselau, C
    [J]. ANALYTICAL CHEMISTRY, 1999, 71 (07) : 1460 - 1463
  • [4] EBERSOLE RC, 1993, BIO-TECHNOL, V11, P1278
  • [5] EWETZ L, 1974, ACTA PATH MICRO IM B, VB 82, P375
  • [6] VIRULENCE CHARACTERISTICS OF ESCHERICHIA-COLI CAUSING FIRST URINARY-TRACT INFECTION PREDICT RISK OF 2ND INFECTION
    FOXMAN, B
    ZHANG, LX
    TALLMAN, P
    PALIN, K
    RODE, C
    BLOCH, C
    GILLESPIE, B
    MARRS, CF
    [J]. JOURNAL OF INFECTIOUS DISEASES, 1995, 172 (06) : 1536 - 1541
  • [7] Glynn JR, 1998, APPL ENVIRON MICROB, V64, P2572
  • [8] ORIENTATION EFFECTS ON THE ELECTROPHORETIC MOBILITY OF ROD-SHAPED MOLECULES IN FREE SOLUTION
    GROSSMAN, PD
    SOANE, DS
    [J]. ANALYTICAL CHEMISTRY, 1990, 62 (15) : 1592 - 1596
  • [9] CARRIER-FREE ZONE ELECTROPHORESIS, DISPLACEMENT ELECTROPHORESIS AND ISOELECTRIC-FOCUSING IN A HIGH-PERFORMANCE ELECTROPHORESIS APPARATUS
    HJERTEN, S
    ELENBRING, K
    KILAR, F
    LIAO, JL
    CHEN, AJC
    SIEBERT, CJ
    ZHU, MD
    [J]. JOURNAL OF CHROMATOGRAPHY, 1987, 403 : 47 - 61
  • [10] A NEW-TYPE OF PH-STABLE AND DETERGENT-STABLE COATING FOR ELIMINATION OF ELECTROENDOOSMOSIS AND ADSORPTION IN (CAPILLARY) ELECTROPHORESIS
    HJERTEN, S
    KUBO, K
    [J]. ELECTROPHORESIS, 1993, 14 (5-6) : 390 - 395