Determination of phthalic acid esters in different baby food samples by gas chromatography tandem mass spectrometry

被引:33
|
作者
Socas-Rodriguez, Barbara [1 ]
Gonzalez-Salamo, Javier [2 ]
Herrera-Herrera, Antonio, V [3 ]
Santana-Mayor, Alvaro [2 ]
Hernandez-Borges, Javier [2 ]
机构
[1] ULL, Serv Gen Apoyo Invest SEGAI, Avda Astrofis Fco Sanchez S-N, San Cristobal De La Lagu 38206, Spain
[2] ULL, Fac Ciencias, Unidad Dept Quim Analit, Dept Quim, Avda Astrofis Fco Sanchez S-N, San Cristobal De La Lagu 38206, Spain
[3] ULL, Inst Univ Bioorgan Antonio Gonzalez, Avda Astrofis Fco Sanchez 2, San Cristobal De La Lagu 38206, Spain
关键词
Phthalic acid esters; Baby foods; QuEChERS; Gas chromatography; Tandem mass spectrometry; SOLID-PHASE EXTRACTION; ELECTROKINETIC CAPILLARY CHROMATOGRAPHY; LIQUID-CHROMATOGRAPHY; PESTICIDE-RESIDUES; QUECHERS METHOD; HUMAN-MILK; INFANT FORMULAS; HUMAN EXPOSURE; PLASTICIZERS; MICROEXTRACTION;
D O I
10.1007/s00216-018-0977-y
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
In this work, a new method has been developed for the determination of 14 phthalic acid esters (i.e., benzylbutyl phthalate (BBP), bis-2-n-butoxyethyl phthalate (DBEP), dibutyl phthalate (DBP), dicyclohexyl phthalate (DCHP), bis-2-ethoxyethyl phthalate (DEEP), diethyl phthalate (DEP), diisodecyl phthalate (DIDP), diisononyl phthalate (DINP), bis-isopentyl phthalate (DIPP), bis (2-methoxyethyl) phthalate (DMEP), dimethyl phthalate (DMP), di-n-octyl phthalate (DNOP), bis-n-pentyl phthalate (DNPP), dipropyl phthalate (DPP)) and one adipate (bis (2-ethylhexyl) adipate (DEHA)) in different baby foods. Separation was carried out by gas chromatography triple quadrupole tandem mass spectrometry while the previous extraction of the samples was carried out using the QuEChERS method. The methodology was validated for four baby food samples (two fruit compotes of different compositions and two meat and fish purees with vegetables) using dibutyl phthalate-3,4,5,6-d(4) (DBP-d(4)) as internal standard. Determination coefficients (R (2)) of matrix-matched calibration curves were above 0.9922 in all cases while relative recovery values ranged between 70 and 120%, with relative standard deviation values below 19%. The limits of quantification of the method ranged between 0.03 and 1.11 mu g/kg. Finally, the analysis of commercially available samples was carried out finding the presence of BBP, DEHA, DEP, DIDP, and DPP in some of the studied samples.
引用
收藏
页码:5617 / 5628
页数:12
相关论文
共 50 条
  • [41] Determination of sucrose esters of fatty acids in food additive premises by gas chromatography and confirmation of identity by gas chromatography/mass spectrometry
    Uematsu, Y
    Hirata, K
    Suzuki, K
    Iida, K
    Kan, T
    Saito, K
    JOURNAL OF AOAC INTERNATIONAL, 2001, 84 (02) : 498 - 506
  • [42] Determination of triethanolamine in air samples by gas chromatography mass spectrometry
    Giachetti, C
    CHROMATOGRAPHIA, 1998, 48 (5-6) : 443 - 449
  • [43] Determination of antipsychotic drugs in hospital and wastewater treatment plant samples by gas chromatography/tandem mass spectrometry
    Logarinho, F.
    Rosado, T.
    Lourenco, C.
    Barroso, M.
    Araujo, A. R. T. S.
    Gallardo, E.
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2016, 1038 : 127 - 135
  • [44] Multiresidue liquid chromatography tandem mass spectrometry determination of 52 non gas chromatography-amenable pesticides and metabolites in different food commodities
    Hernández, F
    Pozo, OJ
    Sancho, JV
    Bijlsma, L
    Barreda, A
    Pitarch, E
    JOURNAL OF CHROMATOGRAPHY A, 2006, 1109 (02) : 242 - 252
  • [45] Gas-chromatography mass-spectrometry determination of phthalic acid in human urine as a biomarker of folpet exposure
    Berthet, Aurelie
    Berode, Michele
    Bouchard, Michele
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2011, 400 (02) : 493 - 502
  • [46] Direct determination of phthalate acid esters in oil feedstock by gas chromatography-mass spectrometry
    Liu, Yulan (liuyl7446@163.com), 2016, Chinese Chamber of Commerce (37):
  • [47] Use of Cycloalkylcarbonyl Derivatives for the Determination of Amino Acid Methyl Esters by Gas Chromatography–Mass Spectrometry
    V. G. Zaikin
    V. V. Luzhnov
    Journal of Analytical Chemistry, 2002, 57 : 498 - 506
  • [48] Gas-chromatography mass-spectrometry determination of phthalic acid in human urine as a biomarker of folpet exposure
    Aurélie Berthet
    Michèle Berode
    Michèle Bouchard
    Analytical and Bioanalytical Chemistry, 2011, 400 : 493 - 502
  • [49] THE ANALYSIS OF SMOKESTACK SAMPLES FOR DIOXINS BY GAS-CHROMATOGRAPHY MASS-SPECTROMETRY AND GAS-CHROMATOGRAPHY TANDEM MASS-SPECTROMETRY
    MOORE, C
    MONCUR, J
    JONES, D
    WRIGHT, B
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 1990, 4 (10) : 418 - 420
  • [50] Fast identification of phthalic acid esters in poly(vinyl chloride) samples by Direct Analysis In Real Time (DART) tandem mass spectrometry
    Akos Kuki
    Lajos Nagy
    Miklos Zsuga
    Sandor Keki
    INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2011, 303 (2-3) : 225 - 228